Search PubMed⌕ Search

PubMed · 6508124

Endolymphatic fistulization.

Abstract

Three previous papers have detailed my experience with various methods of surgical treatment of Meniere's disease: 1) surgery for all patients; 2) surgery for only those patients who demonstrated patency of the vestibular aqueduct as seen on tomographic examination; and 3) prognostic tests to determine which patients were most suitable for endolymphatic sac surgery. This paper details the results of endolymphatic shunt surgery performed on 43 patients over a 3-year period, restudying my prior conclusions. All patients were operated using a new method of capillary endolymph dispersement regardless of tomographic findings. The results are compared to the results of the prior studies to determine whether the findings of tomography are correlated with success or failure of shunt operations, a conclusion that others have questioned. This study clearly shows that the present technique affords better results than prior methods regardless of the x-ray findings. In addition, the tomographic findings correlate closely to the clinical pattern of the disease and to the success or failure of the operation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D F Austin. Endolymphatic fistulization.. https://doi.org/10.1177/000348948409300602

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗