Search PubMedSearch

PubMed · 5392596

[A platelet aggregometer].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Kono, J Isobe, M Yamanaka. 1969. [A platelet aggregometer].. https://pubmed.ncbi.nlm.nih.gov/5392596/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of bedside prothrombin time and activated partial thromboplastin time measurement by coagulation analyzer CoaguCheck Plus in various clinical settings.

In the present study CoaguCheck Plus (CCP), a coagulation test system using whole blood, was evaluated with respect to its comparability with widely distributed conventional routine coagulation assays. A correlation of r = 0.997 (p < 0.0001) was found between INR of CCP-prothrombin time (CCP-PT) and Thrombotest (KC-1 analyzer) in patients on oral anticoagulant therapy. A correlation of r = 0.899 (p < 0.001) between CCP-aPTT and Actin ES aPTT (STA analyzer) was found in heparinized patients. Impaired hepatic hepatic coagulation factor synthesis in liver cirrhosis patients was detected by CCP-PT with a sensitivity of 0.75 and by Normotest (STA analyzer) with a sensitivity of 0.92. Those patients with normal CCP-PT values and liver disease had, only mild reductions (> 30% of normals) in coagulation factors II, V, VII or X. CCP-aPTT was also performed in patients with a deficiency in the so called endogenous coagulation factors VIII, IX, XI and XII. CCP-aPTT showed a sensitivity similar to that of Actin FS aPTT in the detection even of mild deficiencies in factors VIII, IX and XII; factor XI deficiency was however detected only in patients with severe (< 12% of normals) disease; lupus anticoagulants were detected with a high sensitivity.

Blood Coagulation Tests

Sixty-minute alteplase protocol: a new accelerated recombinant tissue-type plasminogen activator regimen for thrombolysis in acute myocardial infarction.

OBJECTIVES: Our aim was to design and evaluate a new and easily administered recombinant tissue-type plasminogen activator (rt-PA) regimen for thrombolysis in acute myocardial infarction (AMI) based on established pharmacokinetic data that improve the reperfusion success rate. BACKGROUND: Rapid restoration of Thrombolysis in Myocardial Infarction (TIMI) grade 3 flow is a primary predictor of mortality after thrombolysis in AMI. However, TIMI grade 3 patency rates 90 min into thrombolysis of only 50% to 60% indicate an obvious need for improved thrombolytic regimens. METHODS: Pharmacokinetic simulations were performed to design a new rt-PA regimen. We aimed for a plateau tissue-type plasminogen activator (t-PA) plasma level similar to that of the first plateau of the Neuhaus regimen. These aims were achieved with a 20-mg rt-PA intravenous (i.v.) bolus followed by an 80-mg i.v. infusion over 60 min (regimen A). This regimen was tested in a consecutive comparative trial in 80 patients versus 2.25 10(6) IU of streptokinase/60 min (B), and 70 mg (C) or 100 mg (D) of rt-PA over 90 min. Subsequently, a confirmation trial of regimen A in 254 consecutive patients was performed with angiographic assessment by independent investigators of patency at 90 min. RESULTS: The comparative phase of the trial yielded, respectively, TIMI grade 3 and total patency (TIMI grades 2 and 3) of 80% and 85% (regimen A), 35% and 50% (B), 50% and 55% (C) and 60% and 70% (D). In the confirmation phase of the trial, regimen A yielded 81.1% TIMI grade 3 and 87.0% total patency. At follow-up angiography 7 (4.1%) of 169 vessels had reoccluded. In-hospital mortality rate was 1.2%. Nadir levels of fibrinogen, plasminogen and alpha2-antiplasmin were 3.6 +/- 0.8 mg/ml, 60 +/- 21% and 42 +/- 16%, respectively (mean +/- SD). Fifty-seven patients (22.4%) suffered from bleeding; 3.5% needed blood transfusions. CONCLUSIONS: The 60-min alteplase thrombolysis in AMI protocol achieved a TIMI grade 3 patency rate of 81.1% at 90 min with no indication of an increased bleeding hazard; it was associated with a 1.2% overall mortality rate. These results are substantially better than those reported from all currently utilized regimens. Head to head comparison with established thrombolytic regimens in a large-scale randomized trial is warranted.

Blood Coagulation Tests

International Normalized Ratio determination using calibrated reference plasmas.

We have compared the conventional method of International Normalized Ratio (INR) determination with an alternative method involving extrapolation from a calibration curve using freeze-dried 'reference' plasmas. The latter approach does not require the determination of a mean normal prothrombin time (MNPT) or local system International Sensitivity Index (ISI). Calibration curves were constructed by plotting local prothrombin time (PT) against assigned INR values for a normal plasma and either two plasma pools from patients on oral anticoagulants or two artificially depleted plasmas. Six laboratories determined the INR of a freeze-dried test plasma and frozen patient plasma samples using the conventional method and by extrapolation. Similarities in the results with the freeze-dried test plasma and the frozen plasmas were encouraging for the projected use with fresh plasma samples. INR values by the conventional method for the test plasma gave an overall mean of 2.73 and inter-laboratory variability (gcv%) of 8.92%, whereas estimates by extrapolation against the normal and patient plasmas or the normal and artificially depleted plasmas gave identical overall mean INR values of 2.70 with inter-laboratory variability (gcv%) of 3.44% and 4.92% respectively. The results indicate that INR determination by extrapolation is associated with reduced interlaboratory variability.

Blood Coagulation Tests