Search PubMedSearch

PubMed · 5365334

Research and development.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N H Martin. 1969. Research and development.. https://doi.org/10.1136/jcp.22.6.628

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fluorescence correlation analysis of probe diffusion simplifies quantitative pathogen detection by PCR.

A sensitive, labor-saving, and easily automatable nonradioactive procedure named APEX-FCS (amplified probe extension detected by fluorescence correlation spectroscopy) has been established to detect specific in vitro amplification of pathogen genomic sequences. As an example, Mycobacterium tuberculosis genomic DNA was subjected to PCR amplification with the Stoffel fragment of Thermus aquaticus DNA polymerase in the presence of nanomolar concentrations of a rhodamine-labeled probe (third primer), binding to the target in between the micromolar amplification primers. The probe becomes extended only when specific amplification occurs. Its low concentration avoids false-positives due to unspecific hybridization under PCR conditions. With increasing portion of extended probe molecules, the probe's average translational diffusion properties gradually change over the course of the reaction, reflecting amplification kinetics. Following PCR, this change from a stage of high to a stage of low mobility can directly be monitored during a 30-s measurement using a fluorescence correlation spectroscopy device. Quantitation down to 10 target molecules in a background of 2.5 micrograms unspecific DNA without post-PCR probe manipulations could be achieved with different primer/ probe combinations. The assay holds the promise to concurrently perform amplification, probe hybridization, and specific detection without opening the reaction chamber, if sealable foils are used.

Automation

Fluorescence-based sequencing of double-stranded DNA by hexamer string priming.

A fluorescence-based, T7 (Sequenase) dye terminator method for sequencing double-stranded DNA using strings of three contiguous hexamers as primers and single-stranded binding protein is described. In this method, the circular, supercoiled DNA vector pUC19 is first linearized with a restriction enzyme to create a sequenceable template. Sequencing is then accomplished using three cycles of "denaturation," annealing, and extension/termination. Twenty-two of 33 hexamer strings tested in a controlled study produced acceptable sequence, with read lengths varying from the mid 300s to the low 400s and a base-calling accuracy of at least 97%. To test its potential utility in directed DNA sequencing, the protocol was then used to completely sequence both strands of pUC19. For this test project, a total of 28 hexamer strings was used with an overall successful priming rate of 75%. The current protocol appears to be sufficiently robust to be used in the finishing phase of a shotgun sequencing project and is amenable to semiautomation. Prospects for using the protocol for full-scale directed sequencing as well as for full automation are discussed.

Automation

Sample preparation with an automated robotic workstation for organic acid analysis by gas chromatography-mass spectrometry.

We attempted to automate sample preparation for analysis of organic acids by gas chromatography-mass spectrometry using a computer-controlled, automated robotic workstation that is integrated and connected to the gas chromatography-mass spectrometry (HP-5890/5971) system. Of the two methods developed, one employed solvent extraction, while the other utilized a silica, solid-phase extraction cartridge. Both automated methods were compared to a manual, solvent extraction procedure used routinely in our laboratory. Normal, spiked urine, and urine from patients with a variety of metabolic abnormalities were analyzed. The robotic workstation did not meet all our requirements for a rapid, reliable, laboratory device. Recoveries with the automated procedures were less than with the manual method, and some organic acids important in the diagnosis of inborn errors of metabolism were not detected. Additionally, the robotic device had mechanical and design problems that made it slower and less reliable than the manual procedure.

Automation