Search PubMedSearch

PubMed · 5046137

Counting every quantum.

Abstract

1. Human subjects were asked to rate both blanks and very dim flashes of light under conditions of complete dark adaptation at 7 degrees in the periphery. The ratings used were 0, 1, 2, 3, 4, 5, and 6.2. For one subject (B.S.) the distributions of ratings were approximately Poisson distributions. The data were consistent with each rating being the actual number of effective quantal absorptions plus the number of noise events. This subject was presumably able to count every rod signal (effective absorptions plus noise).3. For two other subjects, the data were consistent with the ratings being one less (L.F.) and two less (K.D.) than the number of effective absorptions plus noise. They were able to count every rod signal beginning with 2 and 3 respectively. A fourth subject's erratic data could not be fitted.4. The fraction of quanta incident at the cornea that resulted in a rod signal was estimated to be about 0.03 which is consistent with physical estimates of effective absorption for that retinal region.5. A simulated forced choice experiment leads to an absolute threshold about 0.40 log units below the normal yes-no absolute threshold. This and other results indicate that subjects can use the sensory information they receive even when only 1, 2 or 3 quanta are effectively absorbed, depending on the individual. Humans may be able to count every action potential or every discrete burst of action potentials in some critical neurone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Sakitt. 1972. Counting every quantum.. https://doi.org/10.1113/jphysiol.1972.sp009838

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Predicting outcome in central retinal vein occlusion using the flicker electroretinogram.

OBJECTIVE: To evaluate the usefulness of the 30-Hz flicker electroretinogram (ERG) in predicting outcome in patients with central retinal vein occlusion using an automated system previously developed to measure parameters of the flicker ERG and using information about the a priori probability of developing neovascularization of the iris in central retinal vein occlusion. METHODS: Amplitude and timing were extracted from 30-Hz flicker ERGs of 76 patients with acute central retinal vein occlusion from a previous study. The ability of the ERG to predict the development of neovascularization of the iris based on derived parameters was measured using the area under the receiver operating characteristic curve. RESULTS: The predictive ability of the 30-Hz ERG amplitude, as judged by a two-alternative forced-choice procedure, was 92%. The corresponding value for implicit time was 89%. Using Bayes' theorem, we computed the probability of developing neovascularization of the iris based on a single 30-Hz flicker ERG measurement at initial patient presentation. CONCLUSIONS: The 30-Hz flicker ERG provides useful information about the patients with central retinal vein occlusion.

Dark Adaptation