1. Human subjects were asked to rate both blanks and very dim flashes of light under conditions of complete dark adaptation at 7 degrees in the periphery. The ratings used were 0, 1, 2, 3, 4, 5, and 6.2. For one subject (B.S.) the distributions of ratings were approximately Poisson distributions. The data were consistent with each rating being the actual number of effective quantal absorptions plus the number of noise events. This subject was presumably able to count every rod signal (effective absorptions plus noise).3. For two other subjects, the data were consistent with the ratings being one less (L.F.) and two less (K.D.) than the number of effective absorptions plus noise. They were able to count every rod signal beginning with 2 and 3 respectively. A fourth subject's erratic data could not be fitted.4. The fraction of quanta incident at the cornea that resulted in a rod signal was estimated to be about 0.03 which is consistent with physical estimates of effective absorption for that retinal region.5. A simulated forced choice experiment leads to an absolute threshold about 0.40 log units below the normal yes-no absolute threshold. This and other results indicate that subjects can use the sensory information they receive even when only 1, 2 or 3 quanta are effectively absorbed, depending on the individual. Humans may be able to count every action potential or every discrete burst of action potentials in some critical neurone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Sakitt. 1972. Counting every quantum.. https://doi.org/10.1113/jphysiol.1972.sp009838

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

LED-generated multifocal ERG on- and off-responses in complete congenital stationary night blindness -- a case report.

We report on the application of a light emitting diode (LED) screen to elicit multifocal ERG on- and off-responses in a patient presenting with the complete type of congenital stationary night blindness (cCSNB): A 63-years old woman was diagnosed with cCSNB by means of standard ERG procedures and dark adaptometry. To confirm this diagnosis and to investigate topographical differences of on- and off-responses a multifocal approach employing long-duration stimuli was added. Results of mfERG-testing were averaged in three groups (a central area of 7.5 degrees , a ring area of 7.5-21.9 degrees and a peripheral ring of 21.9-31.1 degrees ). When compared to normal controls (n = 4) on-responses (P1-amplitudes) were severely reduced symmetrically at all eccentricities, while off-responses showed no reduction resulting in an increased off/on-ratio. Furthermore on-latencies of P1 were delayed symmetrically at all eccentricities, whereas off-latencies were normal. To our knowledge this is the first report of multifocal on- and off-responses in a CSNB-patient. Stimulus-generation with a LED-screen provides the advantage of a stable luminance during the long-duration on-phase.

Dark Adaptation↗

Is the spectacle lens jack-in-the-box phenomenon really due to the lenses?

The calculation of the extent of the ring scotoma around positive lenses, as conventionally taught to students of clinical optics, indicates that the scotoma is of a significant size. Using knife-edge lenses this study shows that the calculations are invalid due to the finite size of the eye's entrance pupil and in many instances the scotoma is shown not to exist. The effect noticed in clinical practice is probably largely due to the frame and the edging techniques used which add to the refractive scotoma which is present with high powered lenses, large apertures and/or small pupil sizes.

Dark Adaptation↗