Search PubMed⌕ Search

PubMed · 4702547

Electrofluoroplanigraphy.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N A Baily, E C Lasser, R L Crepeau. 1973. Electrofluoroplanigraphy.. https://doi.org/10.1148/107.3.669

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Diamond detector measurements near simulated air channels for narrow photon beams.

BACKGROUND AND PURPOSE: To evaluate the combined effect of increased photon transmission, reduced photon scatter, increased secondary electron range and loss of electronic equilibrium for narrow 6-MV beams in and around a simulated air channel. MATERIALS AND METHODS: A measuring method was developed in-house for relative dose measurements near simulated air-like/soft-tissue interfaces in an automated water phantom. A Styrofoam cylinder (density 0.03 g/cm3) of 2-cm diameter was submersed in the water phantom and irradiated with small rectangular radiation fields. The field length was fixed at 10 cm and the field widths ranged from 1 to 4 cm. The axis of the foam cylinder and the long side of the field were parallel. A water layer of 2 cm was realised upstream of the cylinder. Relative depth dose and profiles behind the foam cavity were assessed using a diamond detector with a sensitive crystal thickness of 0.21 mm located at 1 mm from the top of the encapsulation. RESULTS: The dose at central axis 1.1 mm behind the cavity was found to be 92 and 74% for a field size of 10 x 2 and 10 x 1 cm2, respectively. The highly convex dose profile of the 10 x 1-cm2 field, characterising the homogeneous case, is flattened. CONCLUSIONS: The diamond detector is an excellent choice as a detector in small photon fields with high-dose gradients as they occur near air channels, provided the orientation of the detector is appropriate. Doses near air channels are subject to significant local variations as a function of small changes of field width, and local underdosing may occur in particular cases.

Models, Structural↗

Interfacing a linear diode array to a conventional water scanner for the measurement of dynamic dose distributions and comparison with a linear ion chamber array.

A linear diode array was interfaced to a conventional water scanner for the measurement of dose distribution of dynamically wedged treatment fields. The system was validated by comparing the dose distribution of an open field measured with the system and with a scanning ionization chamber. The system was also compared with a commercial ion chamber array scanner for the measurement of dose distributions of dynamic wedges. The dose distributions of enhanced dynamic wedge fields measured with the two dosimetry systems agree well beyond the depth of maximum dose. However, in the buildup region, the measurements made with the linear diode array system differ by more than 10% from that of the ion chamber array scanner.

Models, Structural↗