N A Baily

Publications and source records attributed to N A Baily.

At least 19 recordsLinked to original sources

Patient exposure requirements for high contrast resolution in digital radiographic systems.

The contrast resolution of modern digital radiographic equipment is primarily limited by quantum mottle. The derivation of the contrast resolution of a system as a function of radiation exposure is presented. Calculations based on this derivation show that achieving 0.8% contrast resolution (128 meaningful gray levels) with 1-mm spatial resolution may require a patient exposure of 1.7 rad (1.7 cGy) per image of a thick body part (20 cm tissue). Acceptable clinical studies often can be obtained with only 5% contrast resolution (20 meaningful shades of gray), but even this level of contrast may require a patient exposure of nearly 90 mrad (0.9 mGy) per image. A comparison of three commonly used methods of reducing patient radiation exposure (pulsed imaging, temporal averaging, and recursive filtering) shows that, in theory, a pulsed system achieves the highest contrast resolution for the same total exposure.

Computers↗

Enhancement of video images.

The enhancement of radiographic and fluoroscopic images using simple video analog techniques is described. In each instance, both the degree of enhancement and the features of the image to be enhanced are under the direct control of the radiologist. Noise is suppressed with a sharp cut-off, low-pass filter. Three types of analog circuits are discussed. One provides edge sharpening and contrast enhancement; one allows either black or white suppression, with expansion of the remaining shades of gray; and one provides an exponential response to selectable portions of the input signal.

Computers, Analog↗

The capability of fluoroscopic systems to determine differential roentgen-ray absorption.

A clinical fluoroscopic unit used in conjunction with a TV image digitization system was investigated to determine its capability to evaluate differential absorption between two areas in the same field. Fractional contrasts and minimum detectability for air, several concentrations of Renografin-60, and aluminum were studied using phantoms of various thicknesses. Results showed that the videometric response, when treated as contrast, shows a linear response with absorber thickness up to considerable thicknesses.

Fluoroscopy↗

Loculation as a contraindication intracavitary 32P-chromic phosphate therapy.

Loculation of instilled 99mTc-sulfur colloid solution in the peritoneal cavity was observed in a patient being considered for intracavitary therapy with 32P-chromic phosphate. Since intracavitary instillation of a therapeutic dose of a radiopharmaceutical agent into a loculated space would risk therapeutic failure and tissue necrosis, prior instillation of a tracer nuclide is recommended to insure adequate dispersion before beginning such therapy.

Child, Preschool↗