Search PubMed⌕ Search

PubMed · 4414930

Optical diffraction analysis of petrographic thin sections.

Abstract

Diffraction patterns that are highly reproducible, of useful quality, and consistent with the input generating them can be easily obtained with a microscope system. The input can be either a reduced photograph or a thin section. With two exceptions, the relationships between a thin section and its diffraction pattern produced by a petrographic microscope are the same as the relationships between a photographic input and its diffraction pattern produced by a conventional ODA system. The exceptions are that the diffraction patterns generated directly by the thin sections may be asymmetrical or, if the thin section is sufficiently heterogeneous, may be smeared. The microscope system is generally more useful than a conventional ODA system for the analysis of microfabric in thin sections. One can readily use the microscope system to analyze elements of widely varying spatial frequency simply by changing the objectives. The diffraction patterns can be magnified by changing to a higherpower ocular. In most cases the microscope-generated diffraction pattern transmits the useful spatial information in the thin section more completely than the conventionally produced diffraction pattern; the photographic inputs for the conventionally produced diffraction pattern emphasize lower-frequency spatial information. This property, combined with the microscope system's better response to twinning, makes the microscope more sensitive to commonly used microfabric elements. For the analysis of thin sections, a conventional ODA system is superior to the microscope system in only three cases. First, if one wants to analyze the entire thin section at one time, a conventional system must be used with a photographic input of the thin section. Second, if the thin section is extremely heterogeneous (crystallographically or mineralogically), the microscope-generated diffraction pattern may exhibit gross smearing even with the highestpower objectives available. Finally, the thin section may contain only elements of low spatial frequency that will not generate diffraction dots far enough radially from the central spot to be resolvable. More study will be needed to establish the precision of spatial frequency measurements from diffraction patterns generated directly by thin sections with the microscope system. Experiments with a variety of film types and sources of illumination will, in all likelihood, lead to a reduction in the exposure times used to record diffraction patterns with the microscope (9). A complete ODA system must have directional and frequency-filtering capabilities. In order to establish these capabilities for the microscope system, components will need to be designed and fabricated and the microscope body may have to be modified. The possibility of applying the microscope technique in reflected light on a real-time basis should be investigated. This would be a valuable tool in the quantitative analysis of microfracture initiation and propagation and the analysis of overall fabric changes during experimental deformation of rock both in situ and in the laboratory. The technique presented here can be used with a less expensive microscope, if it has a focusable Bertrand lens. Our experiments with relatively inexpensive microscopes indicated that the only major problem is alignment of the illuminating system (light-filter-condenser).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P C Power, H J Pincus. 1974-10-18. Optical diffraction analysis of petrographic thin sections.. https://doi.org/10.1126/science.186.4160.234

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Identification of differentially expressed genes in multiple microarray experiments using discrete fourier transform.

Research in the post-genome sequence era has been shifting towards a functional understanding of the roles and relationships between different genes in different conditions. While the advances in genetic expression profiling techniques including microarrays enable detailed and genome-scale measurements, the extraction of meaningful information from large datasets remains a challenging task. Here, we propose a novel method of generating gene differential expression profiles such that gene expression values from one dataset can be directly compared with those of another dataset. A simplified Discrete Fourier Transform is applied to interposed gene expression values, thereby generating the 'spectra' for a pair of conditions. Using this technique, differentially expressed genes produce higher amplitudes at the Nyquist Frequency. By measuring the phase of the 'spectra' generated, the over- and under-expressed nature of the genes can be identified. This method was validated using two sets of GeneChip array data, one from prostate cancer related dataset and the other from macular degeneration related dataset. The genes identified as differentially expressed by our method were found to be similar to those published using their preferred methods. Based on our findings, the proposed DFT method could be used efficiently in identifying differentially expressed genes from multiple-array experiments from two different conditions.

Fourier Analysis↗

Observation of terahertz vibrations in Pyrococcus furiosus rubredoxin via impulsive coherent vibrational spectroscopy and nuclear resonance vibrational spectroscopy--interpretation by molecular mechanics.

We have used impulsive coherent vibrational spectroscopy (ICVS) to study the Fe(S-Cys)(4) site in oxidized rubredoxin (Rd) from Pyrococcus furiosus (Pf). In this experiment, a 15 fs visible laser pulse is used to coherently pump the sample to an excited electronic state, and a second <10 fs pulse is used to probe the change in transmission as a function of the time delay. PfRd was observed to relax to the ground state by a single exponential decay with time constants of approximately 255-275 fs. Superimposed on this relaxation are oscillations caused by coherent excitation of vibrational modes in both excited and ground electronic states. Fourier transformation reveals the frequencies of these modes. The strongest ICV mode with 570 nm excitation is the symmetric Fe-S stretching mode near 310 cm(-1), compared to 313 cm(-1) in the low temperature resonance Raman. If the rubredoxin is pumped at 520 nm, a set of strong bands occurs between 20 and 110 cm(-1). Finally, there is a mode at approximately 500 cm(-1) which is similar to features near 508 cm(-1) in blue Cu proteins that have been attributed to excited state vibrations. Normal mode analysis using 488 protein atoms and 558 waters gave calculated spectra that are in good agreement with previous nuclear resonance vibrational spectra (NRVS) results. The lowest frequency normal modes are identified as collective motions of the entire protein or large segments of polypeptide. Motion in these modes may affect the polar environment of the redox site and thus tune the electron transfer functions in rubredoxins.

Fourier Analysis↗

Truncation effects in SENSE reconstruction.

Finite sampling is an important practical issue in Fourier imaging systems. Although data truncation effects are well understood in conventional Fourier imaging where a single uniform receiver channel is used for data acquisition, this issue is not yet fully addressed in parallel imaging where an array of nonuniform receiver channels is used for sensitivity encoding to enable sub-Nyquist sampling of k-space. This article presents a systematic analysis of the problem by comparing the truncation effects in parallel imaging with those in conventional Fourier imaging. Specifically, it derives a convolution kernel function to characterize the truncation effects, which is shown to be approximately equal to that associated with the conventional Fourier imaging scheme. This article also describes a set of conditions under which significant differences between the truncation effects in parallel imaging and conventional Fourier imaging occur. The results should provide useful insight into interpreting and reducing data truncation effects in parallel imaging.

Fourier Analysis↗