Quantitative technique for bio-electrical spectroscopy.

Abstract

Bio-electrical impedance measurements have been widely used for the study of body tissues. Apart from recordings of biophysical signals (respiration, perfusion, cardiac output, red cell settling, etc.) measurements of specific resistivity of a tissue provide information about its pathological state. Mapping electrical parameters will give more detailed information. The interpretation of recorded data and the design of equipment, both require a preliminary knowledge of the values encountered under normal and pathological conditions. The purpose of the technique described here is to determine the complex resistivity of breast tissue samples in vitro at frequencies between 0.5 kHz and 1 MHz. The equipment is described and the calibration procedure explained. A calculation of the final error interval is given. Characteristic spectra of modulus and phase angle recorded in normal and pathological breast tissue are shown. The technique can however be used for other body tissues, typical applications being fundamental tissue studies and a determination of the most suitable frequencies for use with impedance measuring devices. In clinical practice it could contribute to the determination of intra- and extracellular volume, the monitoring of transplanted organs and the examination of surgically treated tumours, and to any technique based on tissue characterization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Jossinet, A Lobel, C Michoudet, M Schmitt. 1985. Quantitative technique for bio-electrical spectroscopy.. https://doi.org/10.1016/0141-5425(85)90056-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗