Our study of 205 ears with missing stapes, secondary to some type of chronic ear disease, showed that only 40% of such ears are suitable for ossiculoplasty. The remaining 60% are unsuitable because of a fixed footplate, severe atelectasis, hearing better than 25 dB (these patients do not need the operation), or poor discrimination. A new stapes replacement prosthesis (SRP), which we term Tabor, is described for use where indicated. The prosthesis has two parts: The lower part (or base) is made of a broad inorganic, biocompatible material (Teflon). This part fits and covers most of the footplate, ensuring maximal stability. The upper part of the prosthesis is made of autograft or homograft bone--usually a malleus head--the contact of which with the drum prevents extrusion. In twelve out of fourteen ears insertion of this prosthesis was successful; the average postoperative air conduction went from 56 dB to 29 dB, leaving an average air-bone gap of 16 dB. The bone conduction also improved, from an average of 20 dB to 13 dB.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Sadé, E Yaniv, S Avraham, C Fuchs, B Sacs. 1985. Missing stapes and stapes-replacing prosthesis.. https://pubmed.ncbi.nlm.nih.gov/4003537/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A miniaturized artificial mastoid using a skull simulator.

A miniaturized artificial mastoid of size and weight that allow calibration and measurement of bone conduction hearing aids in a conventional audiometric soundproof box has been developed. Its level of mechanical impedance corresponds to the standard IEC 373 (1990) within the frequency range 250 Hz to 8 kHz. The miniaturized artificial mastoid consists of three parts: coupler, skull simulator (TU-1000), and an external electrical correction filter. The coupler is a highly damped mass-spring system designed to give the miniaturized artificial mastoid mechanical impedance in accordance with the standard IEC 373 (1990). It was found that the miniaturized artificial mastoid yielded results that are in correspondence with results obtained with the Brüel & Kjaer type 4930 artificial mastoid for frequencies above 450 Hz. Thus, at these frequencies, the miniaturized artificial mastoid can be used for audiometer calibration as well as measurement of bone conduction hearing aids.

Bone Conduction

Radio frequency hearing: electrostrictive detection and bone conduction.

A hearing aid patented by C. R. Schafer and supposedly based on detection of an amplitude-modulated carrier wave in the auditory cortex was re-examined. It is shown here that the hearing aid actually works by bone conduction of sound. It is concluded that detection of the modulation signal occurs by electrical nonlinearities and electrostriction in the bones of the face and skull.

Bone Conduction

Real-ear measurements in conductive hearing loss: discrepancies between probe-tube microphone measurements and sound field test results.

This study was designed to investigate earlier observations that probe-tube microphone measurements of insertion gain overestimates the functional gain received from hearing aids by users with significant conductive hearing losses. This was originally thought to be due to artefacts in the probe-tube measurement caused by middle ear pathology, but is now believed to be the result of the bone conduction stimulation of the ear exposed to high intensities of airborne sound during sound field threshold measurements. Since the functional gain must relate to the true aided benefit in such cases, these findings suggest that probe-tube microphone measurements in ears with significant air-bone gaps should be interpreted with caution.

Bone Conduction