Search PubMed⌕ Search

PubMed · 3976812

Visual function and academic performance.

Abstract

Evaluation of 1,910 first-, second-, and third-grade students indicated that visual function and academic performance as measured by reading were not positively related. Visual function tests included visual acuity, muscle balance, preferred eye and hand, color vision, refraction, sensory and motor function, and a writing and drawing task. Academic tests included the Metropolitan Readiness Test, the Cognitive Abilities Test, the Iowa Test of Basic Skills, and the teacher's assessment of reading level. A simple test which can be completed during the office visit and interpreted by the ophthalmologist in the office included drawing, copying, and writing. A segment of this test, the "draw a bicycle test," can be used by an ophthalmologist to demonstrate the difference between vision and performance when examining a child up to third-grade level who is referred because of school failure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E M Helveston, J C Weber, K Miller, K Robertson, G Hohberger, R Estes, F D Ellis, N Pick, B H Helveston. 1985-03-15. Visual function and academic performance.. https://doi.org/10.1016/0002-9394(85)90368-x. https://searchpubmed.org/record/pubmed%3A3976812/visual-function-and-academic-performance

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Conceptual model of human blur perception.

An empirically based, conceptual model of human blur perception is presented. It incorporates the concepts of blur detection and blur discrimination in depth, and across the central and peripheral retina, in two- and three-dimensional visual space. Key aspects of the model are its dynamic nature, predictability regarding the blur-based depth-ordering of objects, patterns of retinal defocus with far and near viewing, and interactions related to retinal defocus between the central and peripheral retina. Furthermore, a two-dimensional schematic representation of the blur-free region during near viewing is depicted in dioptric space. This model has implications with respect to accommodative control, depth perception, and refractive error development and progression.

Accommodation, Ocular↗

The effect of human in vivo accommodation on crystalline lens stability.

AIM: To determine the effect of human in vivo accommodation on the stability of the crystalline lens. METHODS: Using a dual Purkinje image (DPI) eyetracker, the phase-time difference and amplitudes of Purkinje images I (P(I)) and IV (P(1V)) were measured in 37 normal emmetropic subjects (34 women and 3 men; mean age 19.8, range 18-22 years) when they changed focus from 70 to 15 cm and simultaneously rotated their heads horizontally from side to side or made horizontal saccades between two targets 6.8 degrees apart. RESULTS: When the subjects changed focus from 70 to 15 cm and rotated their heads or made eye saccades, the phase-time difference between P(I) and P(IV) decreased. During saccades, the amplitude of both P(I) and P(IV) overshoots significantly increased with focus at 15 cm; however, their ratio (P(IV) overshoot amplitude/P(I) overshoot amplitude) significantly declined. CONCLUSIONS: The lens is stable during accommodation. The implications of these findings on the mechanism of accommodation are discussed.

Accommodation, Ocular↗

Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.

PURPOSE: To evaluate the clinical outcomes of an accommodating dual-optic intraocular lens (IOL). SETTING: Private practice and university centers. METHODS: A prospective noncomparative case series with retrospective control comprised 21 patients (26 eyes) scheduled for small-incision extracapsular cataract extraction by phacoemulsification with implantation of the Synchrony dual-optic accommodating IOL (Visiogen) (accommodating IOL group) and 10 patients who had small-incision extracapsular phacoemulsification with implantation of a monofocal, single-optic IOL at least 6 months previously (control group). Patients were examined 1, 3, 6, and 12 months after surgery. Defocus curves in the accommodating IOL group were compared with those in the control group. The main outcome measures were postoperative distance uncorrected and best corrected visual acuity; near uncorrected, distance corrected, and near corrected visual acuity; and accommodative range based on defocus curves. RESULTS: Twenty-four eyes were available at the 6-month follow-up visit. All eyes had best corrected distance visual acuity of 20/40 or better, and 19 eyes (79%) had an uncorrected distance visual acuity of 20/40 or better. Uncorrected near visual acuity was 20/40 or better in all eyes. With distance correction, 23 eyes (96%) had an acuity of 20/40 or better at near. Defocus curve analysis suggested a mean accommodative range of 3.22 diopters (D) +/- 0.88 (SD) (range 1.00 to 5.00 D) in the accommodating IOL group and 1.65 +/- 0.58 D in the control group (range 1.00 to 2.50 D) (P<.05). CONCLUSION: The Synchrony dual-optic IOL shows promise as an option to provide accommodative function in pseudophakic patients.

Accommodation, Ocular↗