Search PubMedSearch

PubMed · 377946

Algorithm-derived, computer-generated interpretive comments in the reporting of laboratory tests.

Abstract

The volume of laboratory and other data that physicians encounter daily is more than most can mentally process without oversight or error. Routine use of computer-generated reminders is one solution to this problem that is now widely suggested. We report our experience with the daily use of a user-written program of algorithm-derived, computer-generated comments in the reporting of chemical profiles and routine thyroid function tests in a busy medium-sized privately owned independent clinical laboratory.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T H McConnell, C T Ashworth, R D Ashworth, C R Nielsen. 1979. Algorithm-derived, computer-generated interpretive comments in the reporting of laboratory tests.. https://doi.org/10.1093/ajcp%2F72.1.32

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A study of unit cost of routine investigations in Srinagarind Hospital.

We have used the step up allocation accounting method to determine the actual costs of complete blood count, urinalysis, chest radiograph and electrocardiogram. We found that the actual costs were quite different from the price set up by the hospital. The actual cost were much higher than the price for the complete blood count and urinalysis and much lower for the chest radiographs and especially for electrocardiogram. We propose that in performing economic analysis involving all these investigations, the actual cost should be used instead of the price.

Blood Chemical Analysis

An evaluation of the Ramco kit for serum ferritin assay.

The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6 micrograms/l to greater than 2 000 micrograms/l there was a correlation coefficient between the two methods of 0,8284 (P less than 0.001). It is concluded that the Ramco kit is suitable for use in clinical practice.

Blood Chemical Analysis

Use of microbore columns for the separation of substances of biological origin.

A gradient system for use with microbore columns is described and the repeatability of the system determined. A simple sampling device for use with aqueous biological samples is described, and the advantages of the high mass sensitivity of microbore columns for the analysis of such samples are discussed. The sensitivity of the system is demonstrated by the determination of acetophenone in water at a level of one part per billion. The use of the apparatus for the separation of low-molecular-weight, non-ionic compounds contained in blood is also demonstrated. It is shown that excellent separations of such components can be obtained from as little as 400 microliter of serum.

Blood Chemical Analysis