Automatic infrared refractors--a comparative study.

Abstract

In order to determine the performance of seven automatic infrared (IR) eye refractors, measurements have been conducted on a model eye as well as on normal subjects and patients under standardized conditions. Concerning the model eye, a range of measurement slightly smaller than specified and linearity errors have been detected on several instruments. Using a group of 55 normal ametropic subjects, the results of the automatic refraction were compared to the results of a conventional subjective examination. The spherical equivalent differed by less than 0.51 D in more than 80% of all cases on all instruments. The error of the cylinder power was smaller than 0.51 D in more than 90% of all cases. Larger errors were found on patients with intra ocular lenses, aphakic eyes, or scattering eye media. In each of these groups the automatic refraction was at times either impossible or yielded a wrong result.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Wesemann, B Rassow. 1987. Automatic infrared refractors--a comparative study.. https://doi.org/10.1097/00006324-198708000-00011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Unexpected cyclotropia simulating disruption of fusion.

Fifteen patients with diplopia associated with prior scleral buckling, prior penetrating keratoplasty, severe corneal scarring, monocular aphakia, long-standing strabismus, or prior vertical offsets of the horizontal recti were thought to have disruption of fusion because diplopia could not be eliminated with prisms. They were each found to have a substantial symptomatic cyclotropia unassociated with an obvious dysfunction of an oblique muscle. In 13 patients, diplopia resolved after the cyclotropia was corrected surgically.

Aphakia

Keratophakia and keratomileusis: safety and effectiveness. American Academy of Ophthalmology.

The purpose of the Committee on Ophthalmic Procedures Assessment is to evaluate on a scientific basis new and existing ophthalmic tests, devices, and procedures for their safety, efficacy, clinical effectiveness and appropriate uses. Evaluations include examination of available literature, epidemiological analyses when appropriate, and compilation of opinions from recognized experts and other interested parties. After appropriate review by all contributors, including legal counsel, assessments are submitted to the Academy's Board of Directors for consideration as official Academy policy.

Aphakia