Search PubMed⌕ Search

PubMed · 3608440

Managing research data with self-documenting files.

Abstract

Processing biomedical research data is frequently complex due to the evolutionary nature of experiments and the requisite modification of analysis software. For the past several years we have been evolving a set of software tools designed to improve our ability to respond to evolving experimental designs. These tools allow the investigator to easily manipulate the research data and specify desired data transformations at run time. Coupling of analysis software to research data files is dependent on data files that are commented in a manner similar to that used in programming languages. The resulting annotated data files are self-documenting, and their use facilitates visual interpretation of displayed data as well as automatic processing of subsets of data. Here we present a formal description of a self-documenting file and describe several software tools that facilitate processing of biomedical research data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C F Starmer, D J Cherveny, M A Dietz, J M Smaltz. 1987. Managing research data with self-documenting files.. https://doi.org/10.1016/0010-4809(87)90058-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Automated recognition of lateral from PA chest radiographs: saving seconds in a PACS environment.

Images acquired in a two-view digital chest examination are frequently not electronically distinguishable. As a result the lateral and posterioanterio (PA) images are often improperly positioned on a PACS work station. A series of 1998 chest radiographs (999 lateral, 999 PA or AP) were used to develop a neural network classifier. The images were down-sampled to 16 x 16 matrices, and a feed-forward neural network was trained and tested using the "leave-one-out" method. Using five nodes in the hidden layer, the neural network correctly identified 987 of the 999 test cases (98.8%) (average of six runs). The simple architecture and speed of this technique suggests that it would be a useful addition to PACS work station software. The accumulated time saved by correctly positioning the lateral and PA chest images on the work station monitors in accordance with each radiologist's hanging protocols was estimated to be about 1 week of radiologist time per year.

Electronic Data Processing↗