Search PubMedSearch

PubMed · 3306123

[Implants in surgery].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Baev, M Stoianova, R Radev. 1987. [Implants in surgery].. https://pubmed.ncbi.nlm.nih.gov/3306123/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radiation dose perturbation at tissue-titanium dental interfaces in head and neck cancer patients.

PURPOSE: To determine the dose perturbation effects at the tissue-metal implant interfaces in head and neck cancer patients treated with 6 MV and 10 MV photon beams. METHODS AND MATERIALS: Phantom measurements were performed to investigate the magnitude of dose perturbation to the tissue adjacent to the titanium alloy implants with (100 mu and 500 mu thick) and without hydroxylapatite (HA) coating. Radiographic and radiochromic films were placed at the upper (and lower) surface of circular metal discs (diameter x thickness: 15 x 3.2, 48 x 3.2, 48 x 3.8 mm2) in a solid water phantom and were exposed perpendicular to radiation beams. The dosimeters were scanned with automatic film scanners. Using a thin-window parallel-plate ion chamber, dose perturbation were measured for a 48 x 3.2 mm2 disc. RESULTS: At the upper surface of the tissue-dental implant interface, the radiographic data indicate that for 15 x 3.2 mm2 uncoated, as well as 100 mu coated discs, dose perturbation is about +22.5% and +20.0% using 6 MV and 10 MV photon beams, respectively. For 48 x 3.2 mm2 discs, these values basically remain the same. However, for 48 x 3.8 mm2 discs, these values increase slightly to about +23.0% and +20.5% for 6 MV and 10 MV beams, respectively. For 48 x 3.2 mm2 discs with 500 mu coating, dose enhancement is slightly lower than that obtained for uncoated and 100 mu coated discs for each beam energy studied. At the lower interface for 15 x 3.2 mm2 and 48 x 3.2 mm2 uncoated and 100 mu coated discs, dose reduction is similar and is about -13.5% and -9.5% for 6 MV and 10 MV beams, respectively. For 48 x 3.8 mm2 discs, dose reduction is about -14.5% and -10.0% for 6 MV and 10 MV beams, respectively. For 48 x 3.2 mm2 discs with 500 mu coating, the dose reduction were slightly higher than those for uncoated and 100 mu coated discs. CONCLUSIONS: For the beam energies studied, dose enhancement is slightly larger for the lower energy beam. The results of dose perturbation were similar for 100 mu coated and uncoated discs. These results were slightly lower for the 500 mu coated discs but are not clinically significant. The dosimetry results obtained from radiochromic films were similar to the ones obtained from radiographic film. The dose enhancement results obtained from ion chamber dosimetry are higher than those obtained from film dosimetry. The ion chamber data represent the data at "true" tissue-titanium interface, whereas the ones obtained from film dosimetry represent the data at film-titanium interface.

Biocompatible Materials

Human chondrocytes proliferate and produce matrix components in microcarrier suspension culture.

Chondrocytes propagated in monolayer culture proliferate and change into 'fibroblastoid'-like cells. This change is characterized by a shift in production of collagen type II to I and from high- to low-molecular-weight proteoglycans. When propagated in three-dimensional culture, chondrocytes have limited ability to divide but re-express their original characteristics. The goal of the present study was to determine whether a microcarrier suspension culture system would support chondrocyte proliferation and phenotype expression. Our experiments indicate that a collagen type I microcarrier (cellagen) best supported chondrocyte proliferation and phenotype expression. Cells in cellagen microcarriers multiplied at least twentyfold within 2 weeks and had doubling times of 2 to 3 d. Viable and metabolically active cells were retrieved with ease. The harvested chondrocytes had no detectable staining for collagen type I and stained intensely for collagen type II. Our studies demonstrate that the microcarrier suspension culture system supports growth and enhances expression of the 'chondrocytic' phenotype. Attachment to a constrained surface and the fluid shear forces on the microcarriers during suspension culture may have helped chondrocytes to reacquire their rounded shape and produce cartilage matrix components.

Biocompatible Materials

Modulation of the dissolution profiles from Geomatrix multi-layer matrix tablets containing drugs of different solubility.

A new multi-layer tablet design has recently been proposed for constant drug release: Geomatrix Technology (Jago Pharma, Muttenz, Switzerland). It consists in the application of a drug-free barrier layer on one or both bases of an active core (hydrophilic matrix). The partial coating modulates the core hydration process and reduces the surface area available for drug release. The result is an extended release that draws close to a linear profile. The device was mainly intended for soluble drugs, while an excessive reduction of the release rate may be obtained with drugs of low solubility. In this study a new time-dependent polymeric barrier is proposed to control the release of sparingly soluble drugs. Two different barrier compositions (one swellable and one erodible) are applied on active cores containing drugs of different water solubility, Trapidil, Ketoprofen and Nicardipine hydrochlorides, and the drug dissolution patterns of the different multi-layer devices are compared. During dissolution, the swellable barrier swells and gels, but is not eroded, thus acting as a modulating membrane during the release process. The erodible barrier, instead, is progressively removed by the dissolution medium, exposing in time an increasing extent of the planar surface(s) of the core to interaction with the outer environment and to drug release. Both types of coatings are able to control drug release from the devices: the swellable barrier shows a stronger modulation efficiency and is more suitable to modify the delivery pattern of highly soluble drugs; the erodible barrier shows a time-dependent coating effect that provides better control of the dissolution profile of sparingly soluble drugs.

Biocompatible Materials