Search PubMedSearch

PubMed · 3259666

Solid-phase optoelectronic biosensors.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C R Lowe, M J Goldfinch. 1988. Solid-phase optoelectronic biosensors.. https://doi.org/10.1016/0076-6879(88)37033-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Limitations of serum prostate specific antigen in predicting peripheral and transition zone cancer volumes as measured by correlation coefficients.

PURPOSE: We reexamined the relationship between preoperative serum prostate specific antigen (PSA) and prostate cancer volume in 290 patients who underwent radical prostatectomy. MATERIALS AND METHODS: Serum samples from 290 consecutive patients were remeasured with the automated monoclonal-monoclonal Tosoh AIA-600 assay. These values were correlated with individual cancer volume by measuring Pearson correlation coefficients (r). RESULTS: Cancer was noted in the transition zone in 31 patients and in the peripheral zone in 259. Of the peripheral zone cancers 133 (51.4%) were organ confined and 126 (48.6%) were nonorgan confined, including 12 (9.5%) with histologically confirmed lymph node metastasis (stage D1). The 259 peripheral zone cancers had a correlation coefficient with PSA (r = 0.499, p < 0.0001). After distributing the 259 cases into cancer volume groups we found a large overlap in mean preoperative serum PSA, including 65 with 50% or greater Gleason grade 4 or 5 disease (r = 0.508). The correlation coefficients of cancer volume with PSA in 133 organ confined cancers, 114 nonorgan confined cancers without lymph node metastases and 12 nonorgan confined cancers with positive lymph nodes were 0.382, 0.438 and 0.363, respectively. The 31 transition zone cancers showed a correlation coefficient with PSA (r = 0.81). After excluding 2 cases with extreme PSA and cancer volume the correlation coefficient decreased (r = 0.077). CONCLUSIONS: Even when remeasured with an automated monoclonal-monoclonal assay serum PSA alone is unable to predict preoperatively cancer volume or distinguish between organ and nonorgan confined cancer in peripheral and transition zone tumors of the prostate.

Autoanalysis

Band width measurement in automated gel electrophoresis apparatus: DNA dispersion in a discontinuous system and in a single buffer.

Recent commercial introduction of automated gel electrophoresis apparatus allows for band width measurements during electrophoresis and therefore promises to open up the exploitation of band width and shape for the physical characterization of charged macromolecules in the same manner in which to date quantitative gel electrophoresis had exploited electrophoretic mobility at multiple gel concentrations. The measurements demonstrate decreased band width and therefore increased resolving power for a discontinuous buffer system compared to Tris-borate EDTA buffer. The dispersion coefficients (D' = (sigma 2-sigma 2o)/t) of homogeneous DNA components appear to decrease with gel concentration when either the field strength or the DNA length is small, and increase with gel concentration when these are large. This contrasting response of D' to increasing gel concentration is presumably due to DNA stretching, which increases in proportion to DNA length and field strength, and to the progressive orientation of agarose with increasing field strength.

Autoanalysis

Nonlinear "Ferguson curves" by two runs of the commercial automated HPGE-1000 gel electrophoresis apparatus with intermittent scanning of fluorescence.

The exploitation of gel electrophoretic migration distance to gain information of molecular and gel fiber properties depends on the functions relating mobility with gel concentration. To the degree that these are nonlinear, the definition of those functions by past methods has been excessively laborious or, in application of gel concentration gradients, based on a number of assumptions. The recent commercial introduction of gel electrophoresis apparatus capable of intermittent scanning of the pattern promised to solve these problems. The present study shows that such apparatus allows for a precise definition of a nonlinear "Ferguson curve" (mobility vs. gel concentration) in two experiments, using different gel concentrations in the eight channels of the HPGE-1000 apparatus and 5-29 scans in each during the course of an electrophoretic run. Simultaneously, these Ferguson curves are obtained for five components of a DNA ladder ranging in DNA length from 121 to 1857 bp.

Autoanalysis