Search PubMed⌕ Search

PubMed · 3216169

A real-time data-logger system using an optical disk WORM for archiving continuous 12-lead ECG data during exercise testing.

Abstract

An exercise ECG analysis program was developed over 15 years on a number of mainframes, minicomputers and, most recently, microcomputer-based systems. It has been rehosted into both Motorola MC68000 and Intel 80286 microprocessor-based development systems and is currently used with a removable 200 Mbyte optical disk (Write-Once-Read-Many, WORM) based data-logger system that can record and store all 12 leads simultaneously and continuously for an entire exercise test (up to 38 minutes). Data is acquired with 12-bit A/D resolution at 500 samples/sec. All ECG data and patient information are archived on the optical disk for later off-line recall and analysis on a PC or real-time replay through a D/A converter. Recorded ECG signals are at patient levels so they can be replayed through the patient cable box on any commercial system. Current development includes both simultaneous on-line processing and storage of 12-lead ECG data and off-line processing and development performed on the long-term, continuous ECG data being archived on optical disk. Patient medical histories and clinical information are separately entered into an applications database, where ECG measures and test results are later included. This new optical disk based exercise ECG database contains more than 600 complete exercise tests and is projected to increase to nearly 3,000 within 2 years.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J N Froning, V F Froelicher, M D Olson. 1988. A real-time data-logger system using an optical disk WORM for archiving continuous 12-lead ECG data during exercise testing.. https://doi.org/10.1016/0022-0736(88)90082-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗