Search PubMedSearch

PubMed · 3187002

Osteomyelitis: detection with US. Work in progress.

Abstract

Ten patients with clinically suspected osteomyelitis were studied with ultrasound (US). Five patients had abnormalities detectable on sonograms. An abnormal fluid collection was demonstrated adjacent to the bone in three of these five. US-guided aspiration of the fluid in two of the three patients revealed purulent or infected fluid that was thought to represent an inflammatory exudate dissecting in a subperiosteal or extraperiosteal location. Findings from subsequent radiographic and scintigraphic studies confirmed the diagnosis of osteomyelitis in these three patients. The other two patients with abnormal sonographic results had collections of fluid that were separated from the bone by a variable amount of soft tissue. These collections were confined to the soft tissue and did not appear to arise from the bone. Aspiration revealed a soft-tissue abscess in one patient and a seroma in the second. Findings in this preliminary study suggest that fluid around the bone seen on sonograms may indicate acute osteomyelitis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M M Abiri, M Kirpekar, R C Ablow. 1988. Osteomyelitis: detection with US. Work in progress.. https://doi.org/10.1148/radiology.169.3.3187002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acute spermatic cord torsion alters the microcirculation of the contralateral testis.

PURPOSE: The purpose of this study was to characterize the hemodynamic changes in the contralateral testis during acute spermatic cord torsion in anesthetized rats. MATERIALS AND METHODS: We used videomicroscopy to examine the microcirculation of the contralateral testis following acute torsion. Specifically, we examined the effect on vasomotion, a rhythmic dilation and constriction of the arterioles that is involved in fluid and nutrient exchange and modulation of local vascular resistance. In a separate set of experiments, blood flow in the contralateral internal spermatic artery was measured with an ultrasonic flow probe during acute torsion. RESULTS: Following 720 degrees torsion, the amplitude of vasomotion in the contralateral testis increased 121% (29.0 +/- 3.9% versus 13.0 +/- 1.7%) compared with controls. Blood flow in the contralateral internal spermatic artery decreased 43% after 2 hours' torsion. CONCLUSIONS: Acute spermatic cord torsion altered the microcirculation by increasing the amplitude of vasomotion and decreased total blood flow to the opposite testis. Because the hydraulic resistance of a blood vessel exhibiting vasomotion is always less than a vessel with the same average but static diameter, the observed microcirculatory changes may be an adaptive response to preserve local flow in the presence of decreased total flow. The long-term consequences of these changes in the microcirculation may affect testicular function and ultimately fertility.

Acute Disease