Improving Falope-Ring application in laparoscopy training.

Abstract

Laparoscopic Falope-Ring sterilization was performed by residents on 71 women. Immediately following application of the ring, methylene blue was injected through the cervix to assess tubal patency. Unilateral spillage of the dye was demonstrated in four patients (5.6%). In these instances a new ring was applied, or the tube was tied surgically. The high rate of tubal patency was attributed to the surgeons' inexperience. The findings suggest that the use of a patency test as an adjunct to sterilization with the Falope-Ring in training programs is likely to decrease the rate of surgical failures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Aubert, A Garcia. 1987. Improving Falope-Ring application in laparoscopy training.. https://pubmed.ncbi.nlm.nih.gov/2955116/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fallopian tube occlusion, an alternative to tubal ligation.

Diagnosis of fallopian tube pathology has been performed with X-rays, ultrasound, magnetic resonance imaging, and even nuclear medicine exams. However, fallopian tube interventions are almost exclusively the domain of fluoroscopy. Fallopian tube interventions can be divided into two categories: embolization and recanalization. The former has only recently been described using imaging guidance while the latter has been accepted as a safe and effective procedure since the early 1990s. This article will highlight the technique and results associated with fallopian tube embolization.

Fallopian Tube Patency Tests↗

Role of hysterosalpingoscintigraphy in the workup of infertility.

OBJECTIVE: To assess the role of hysterosalpingoscintigraphy (HSSG) in the evaluation of fallopian tube patency and function and compare the results with hysterosalpingography (HSG) and laparoscopy (LS). DESIGN: Cross-sectional study. PLACE AND DURATION OF STUDY: The study was conducted at Multan Institute of Nuclear Medicine and Radiotherapy (MINAR), Multan from August 2004 to February 2005. PATIENTS AND METHODS: HSSG was performed after instillation of 4mCi (148 MBq) 99mTechnetium-macroaggregated albumin (99mTc-MAA) in posterior vaginal fornix in 65 patients. Serial static images were acquired in supine position at 1 hour, 2 hours, 3 hours and, if needed, at 24 hours. The results were compared to the findings on LS and HSG. RESULTS: Out of 65 patients, 37 (56.9%) patients had bilateral blocked tubes, 17 (26.1%) patients had bilateral patent tubes, 6 (9.2%) patients had blocked left tube and 5 (7.1%) patients had blocked right tube. The calculated sensitivity, specificity, positive predicted value (PPV), negative predicted value (NPV) and accuracy for HSSG were 90%, 83%, 90% and 90% respectively. The agreement between HSSG and LS was found in 32 out of 35 patients and agreement between HSG and HSSG was found in 24 out of 30 patients. CONCLUSION: This simple procedure can delineate tubal physiology; in selected cases it can replace HSG and in others augment the information gathered by HSG. HSSG should be part of the infertility workup algorithm.

Fallopian Tube Patency Tests↗