Search PubMed⌕ Search

PubMed · 28263

Polyarteritis nodosa causing severe intestinal bleeding.

Abstract

Rupture of an aneurysm of the mesentergic artery caused severe intestinal hemorrhage in a 50-year-old woman with polyarteritis nodosa. Abdominal angiography not only established diagnosis of polyarteritis nodosa by demonstrating multiple visceral aneurysms but also localized the site of bleeding.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Y Han, H P Jander, H L Laws. 1976-11-30. Polyarteritis nodosa causing severe intestinal bleeding.. https://doi.org/10.1007/bf02256382

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mechanistic insights into Claudin-14 dysfunction implicated in veins of Galen malformation.

Claudin-14 (CLDN14) is a key component of tight junctions (TJs) critical for maintaining paracellular barrier function. Variants of CLDN14 have been linked to Vein of Galen malformations (VOGMs), a rare cerebrovascular disorder; however, the molecular mechanisms underlying their pathogenicity remain unknown. Here, we investigate the mechanistic effects of two VOGM-associated mutations, A113P and V143M, using reinforcement-learning driven enhanced sampling molecular dynamics simulations combined with DiffNets-based deep learning and independent trajectory-wide structural analyses. Our analysis reveals that A113P induces broader structural disruption of CLDN14, perturbing paracellular sealing, pore symmetry, and inter-protomer communication, whereas V143M induces structural rearrangements centred around TM3 and the TM3-ECL2 region. In both cases, mutation-specific alterations are observed in structural stability and interfacial organization across oligomeric assemblies. Notably, these effects are qualitatively consistent across different modelled architectures, despite variability in local responses. In the absence of experimentally resolved structures, the structural perturbations reported here provide a mechanistic understanding of how VOGM-associated variants may influence CLDN14 structure and dynamics.

Aneurysm↗

Covered stent for renal artery aneurysm.

This is a case of a 51-year-old female with difficult-to-control hypertension and a 3-cm renal artery aneurysm. Successful exclusion of this was performed using a prefabricated stent graft. To our knowledge, this is the first report on the use of a prefabricated covered stent for this indication.

Aneurysm↗

Real-time observation of hemodynamic changes in glomerular aneurysms induced by anti-Thy-1 antibody.

BACKGROUND: Blood flow in the microvasculature plays a pivotal role in determining the outcome of injury and repair in inflamed tissue. Real-time observation of the kidney microvasculature, including the glomerular capillary tufts, is extremely difficult because of the methodological limitations of currently available microscope optics. In the present study, we attempted to analyze hemodynamic events that occurred in vivo during microvascular regeneration following destruction of the glomerular capillary tuft, functionally and quantitatively by the use of a real-time confocal laser-scanning microscope (CLSM) system. METHODS: A polyethylene catheter was inserted into the carotid artery to allow blood pressure measurement. Mesangiolytic lesions producing microaneurysms were induced by the injection of anti-Thy-1.1 antibody. On days 3 and 7 after antibody injection, we examined hemodynamic changes under an intravital microscope equipped with real-time CLSM in combination with a high-speed CCD video camera. To measure vessel diameter and erythrocyte velocity, rats were injected with fluorescein isothiocyanate (FITC)-labeled dextran and FITC-labeled red blood cells (RBCs). RESULTS: On day 3 of the disease, mean arterial blood pressure was 112 +/- 5 mm Hg, which was significantly higher than that of normal rat or of rats on day 7 (93 +/- 1 and 101 +/- 9 mm Hg, respectively). Within mircroaneurysms on day 3, RBC velocity was greatly suppressed. By day 7, RBC velocity, in glomeruli with normal appearances, recovered to about half of the level seen in normal controls (430.6 +/- 284.7 microm/sec), while in narrowed glomerular tufts, it was still only 104.6 +/- 35.1 microm/sec. CONCLUSIONS: The noninvasive procedure, using CLSM in combination with a high-speed video camera, allowed us to examine hemodynamic events quantitatively and to analyze microvascular architecture three dimensionally in the kidney. It is useful for estimating hemodynamic response and vascular regeneration in vivo and may be promising for clinical application.

Aneurysm↗