Microprocessor controlled particle counter system.

Abstract

Operation of an optical particle counter with microprocessor control of particle size calibration and data recording is described. Sensors are available to measure particles 0.1 micron and larger. A system with a range from 2 microns to 125 microns will be described. Calibration data based on response to monosized particles are stored in the system memory, along with sensor resolution information and system changes since the last calibration. The instrument adjusts the particle size channels internally for the selected calibration base particles. Once calibrated, the instrument can be set to report data in operator selectable sizes or any of four default particle size groups. Three default groups are based on pharmaceutical and hydraulic fluid power industry standards and one is set in a logarithmic spread of 16 particle sizes that covers the system dynamic range. A front-panel keyboard and CRT display allow selection and control of all operating parameters. These include reported size ranges, liquid sample size, number of sample replications (including suspect sample rejection), data averaging, and comparison of data from two sensors. Differential or cumulative data can be reported in tabular or histogram format. Data can be sent to an internal thermal printer or to an RS-232C output.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Lieberman. Microprocessor controlled particle counter system.. https://pubmed.ncbi.nlm.nih.gov/2370623/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of eperisone in human plasma by gas chromatography-mass spectrometry.

A gas chromatographic-mass spectrometric method was developed to determine eperisone hydrochloride, 4'-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride, in human plasma over the concentration range 0.2-40 ng/ml. Excellent sensitivity was achieved by selection of a favorable fragment ion, m/z 98, of eperisone and reduction of heat decomposition of eperisone by using a splitless injector and a shortened capillary column. The method described here allows the determination of plasma concentrations as low as 0.2 ng/ml, the concentration attained 6 h after a single oral administration of 50 mg. At eperisone hydrochloride concentrations higher than 0.5 ng/ml, the mean inter-day variation of accuracy of the assay was less than 12%.

Calibration

Video analysis of DNA sequence homologies.

A method for the rapid quantitative analysis of dot blot assays is presented. A video camera, an NTSC compatible frame grabber board, and an AT personal computer are used to read photographic exposures of the assay plate. Image processing and image analysis techniques are used to calculate the orientation of the dot raster and then to compensate for the effect of variations in field illumination on measurements of local contrast. Local contrast (between dots and background) is an exponential function of the amount of hybridization between blotted DNA and complimentary oligonucleotide probes. The amount of hybridization between blotted DNA and oligonucleotide probes of known sequence is the criteria used to establish HLA-DR tissue types. Although the assay described here utilizes a chemiluminescent reaction, this algorithm may be used to read any assay that produces a rectangular raster of dots.

Calibration

Analysis of terbutaline in human plasma by high-performance liquid chromatography with electrochemical detection using a micro-electrochemical flow cell.

A high-performance liquid chromatographic method is described for the determination of terbutaline in human plasma in the range 1-35 ng/ml. Detection was achieved using a carbon fibre micro-electrochemical detector and a column-switching system. The microelectrode cell has advantages over conventional glassy carbon electrode-based detection systems in that it is easy to prepare, flexible in its operation and suffers less trouble from problems such as air bubbles and leaks. Furthermore, it has a better detection limit for terbutaline (0.8 ng/ml) to that obtained using a conventional glassy carbon electrode flow detector (2 ng/ml). Sample clean-up was by on-line solid-phase extraction with column switching, providing a method which was sensitive and reproducible, where the mean overall coefficient of variation was 5.60% and drug recovery in excess of 86% at the concentration levels studied.

Calibration