Search PubMed⌕ Search

PubMed · 2306563

Design of a microprocessor-based sphygmomanometer.

Abstract

This paper describes the implementation on a microprocessor of a new method for the indirect measurement and recording of the systolic and diastolic blood pressure in humans. The technique is based on a statistical analysis of the cardiac pulse pressure signal. Polynomial relations are derived between the amplitude of the pulsatile pressure waveforms at the systolic and diastolic points and the amplitude of pulse signals detected when the artery is fully occluded. With the dual objective of automating the measurement procedure and minimizing errors, an electronic analog-digital sphygmomanometer that contains suitable electronic instrumentation was developed. The functions of processing the pressure signal, automating the measurement, and recording the results are performed and controlled by a microprocessor. A laboratory prototype embodying this approach was constructed and its performance and reliability were verified using a series of clinical tests. The test results indicate that the device is accurate within acceptable bounds for automated blood pressure instruments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K C Kalaitzakis, N E Papamarkos, G J Vachtsevanos. Design of a microprocessor-based sphygmomanometer.. https://pubmed.ncbi.nlm.nih.gov/2306563/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A user-friendly PC-based data acquisition and analysis system for respirometric investigations.

We have developed an easy-to-use computer-based system for recording, displaying, storing and analyzing signals generated by Clark-type oxygen electrodes. A user-friendly interface of Windows-based program BioMed significantly increases the productivity of investigations. It allows to process, control, present and archive the experimental data in real time. A 12-bit analog-to-digital-converter, analog and digital filters, a possibility to zoom the obtained respiratory curves and calculation of the respiration rates by a linear regression method increase the resolution of the estimated oxygen consumption rates. The new system enables to register even small changes, such as 3-5 ngatoms O/min, in respiration rates of biological objects -- enzymes, mitochondria and permeabilized muscle fibers. The system has been developed and is regularly used for the respirometric investigations at the Laboratory of Biochemistry, Institute for Biomedical Research, Kaunas University of Medicine.

Analog-Digital Conversion↗

Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.

Analog-Digital Conversion↗