Search PubMedSearch

PubMed · 2174641

Decrease of beta-receptors after the antigen-specific bronchial provocation test in bronchial asthma.

Abstract

Airway hyperreactivity to different stimuli is a characteristic feature of bronchial asthma. The beta-adrenergic theory, as proposed by Szentivanyi in 1968, tried to explain with beta-adrenergic dysfunction, the cause not only of bronchial hyperreactivity but of all atopic diseases. In a previous work, we found that asymptomatic asthmatic patients presented a number of beta-receptors similar to that of a normal control group, while symptomatic asthmatic patients presented a significantly decreased number when compared to both groups (40% decrease). In view of these results, we proposed to study the possible changes in the number of beta-receptors in asymptomatic asthmatic patients after a bronchial provocation test. Fifteen patients, diagnosed of bronchial asthma and sensitive to the house dust mite, D. pteronyssinus, were studied. All were free of medication and asymptomatic at least 90 days before the study. A test of specific bronchial provocation was performed on 10 patients, determining the number of beta-receptors in basal conditions, after 30 minutes and 24 hours. The other five patients underwent an unspecific provocation test with methacholine, with determination of the beta-receptor number at basal conditions, and 24 hours later. Only a significant decrease (30.4%) was found in the beta-receptor numbers, 24 hours after specific bronchial provocation with p less than 0.025 with the Student test for paired data. With regards the beta-adrenergic theory of atopy, in our opinion our results show that the detected decrease of beta-receptors would be the consequence and not the cause of atopic diseases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P M Gamboa, C G de la Cuesta, M L Sanz, B E García, A Oehling. Decrease of beta-receptors after the antigen-specific bronchial provocation test in bronchial asthma.. https://pubmed.ncbi.nlm.nih.gov/2174641/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Differences of draining lymph node cell proliferation among mice, rats and guinea pigs following exposure to metal allergens.

Contact sensitivities of three well known metal allergens (nickel sulfate, potassium dichromate and cobalt chloride) were examined using the local lymph node assay in CBA/N mice, F344 rats and Hartley guinea pigs. The effect of various species sera on lymph node cell (LNC) proliferation was also investigated. Exposure to potassium dichromate and cobalt chloride induced significant LNC proliferative responses in the three species. The LNC responses to potassium dichromate in the rats were higher than those in the mice and guinea pigs. Mice exhibited the highest response to cobalt chloride among the three species, whereas, exposure to nickel sulfate failed to induce a marked LNC proliferation. Increased draining lymph node weights and LNC numbers were also observed following exposure to the metal salts. However, these parameters were less sensitive compared with the LNC proliferative response. There was a large difference in the lymph node weight between individual guinea pigs. The [methyl-3H]thymidine incorporation into LNC of each species cultured in the presence of the homologous serum in vitro was lower than in the presence or absence of fetal calf serum. However, there was no significant difference in stimulation indices among the different culture conditions. The local lymph node assay may be performed in rats as well as in mice for the detection of metal allergens.

Allergens

[Occupational asthma].

The diagnosis of occupational asthma requires the integration of a multiplicity of data; the history, cutaneous skin tests, biological tests, respiratory function tests and non-specific tests of bronchial hyperreactivity and specific bronchial provocation test. The history search for the presence of an atopic state, the occurrence of similar disorders in members of the same firm and also the timing of symptoms in relation to the occupational activities. Cutaneous tests are particularly helpful in IgE-mediated asthma in relation to the inhalation of animal or vegetable materials of glycoprotein origin. For haptens, the need for their prior coupling to a protein carrier causes problems which have not been entirely resolved. Laboratory tests run into the same snags. Respiratory function and non-specific bronchial provocation tests, confirm the diagnosis of asthma and enable the medium and long term prognostic to be assessed. Specific bronchial provocation tests are the most appropriate tests to establish an aetiological diagnosis in occupational asthma. Different technical methods are possible: quantitative administration of allergen aerosols, realistic tests, and tests using exposure chambers to achieve true test doses. The products responsible for occupational asthma are multiple. The different substances are characterised in a simplified manner: first animal matter (mammalian and arthropod allergens), secondly substances of vegetable origin (roots, leaves, flowers, grain and flour, wood and its derivates) and finally chemical products. The chemical products are primarily from the pharmaceutical and metal industries and above all from the plastics industry.

Allergens