Search PubMed⌕ Search

PubMed · 2076840

Distal push splint.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D R Bailey. Distal push splint.. https://pubmed.ncbi.nlm.nih.gov/2076840/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Differences between two transpalatal arch systems upon first-, second-, and third-order bending activation.

Transpalatal arches are used in passive mode to improve anchor-age and in activated mode to achieve single tooth movement or movement of segments of teeth in first-, second- and third-order. Clinically it seems that the commonly used palatal arches of the Goshgarian type (here in the MIA system) as well as the precision TMA lingual arches of the Burstone system are not equally suitable for all kinds of activations. Using the Orthodontic Measurement and Simulation System (OMSS) the force systems and the efficacy of activated arches of both systems were examined in an experimental study with respect to different malpositions. The following first-, second- and third-order activations were chosen: symmetrical expansion and compression up to 4 mm, symmetrical distal rotation up to 15 degrees, unilateral distal tipping of 15 degrees and symmetrical buccal root torque up to 10 degrees. Attachments of the MIA system (MIA Rotation Lingual Sheaths, 0.072" x 0.036") and of the Burstone system (precision lingual hinge cap, 0.032" x 0.032", unused and a pair after a 4-week introral application period) were measured. Lingual arches made of 0.036" round stainless steel wire (MIA) and 0.032" x 0.032" TMA (Burstone system) were prepared with a height of 18 mm and a width of 30 mm. First-order activation bends (expansion and compression) of the MIA palatal arches caused forces up to 4.4 N compared to 1.8 N of the TMA arches, due to the lower load/deflection rate of the latter. The malpositions were corrected effectively by both systems. Due to the higher stiffness the moments delivered by the MIA palatal arches (39 Nmm) were higher in distal rotation compared to those of the TMA arches (14 Nmm) and the correction was more effective. In second-order activations (tipping) the MIA system delivered no or only small moments because of the curved shape of the attachments. A correction of only 30% was achieved compared to 80% with the Burstone system. In third-order activations, in contrast, the Burstone attachments caused considerable loss of torque. This was obviously due to the strong deformation of the slot by the intraoral loading. If it were possible to improve the dimensional stability of the hinge cap, all corrections carried out with the Burstone TMA system would involve distinctly smaller forces and moments than the MIA system but would still ensure good effectiveness.

Activator Appliances↗

Tensor analytical evaluation of the effects of a skeletonized activator in the treatment of Class II, Division 1 patients.

PATIENTS AND METHOD: The study covered 40 patients (21 boys and 19 girls) whose Class II, Division 1 malocclusion was being treated with a Klammt open activator. To illustrate growth changes, tensor analysis was used as a superimposition-free comparative technique. At the beginning of treatment for Class II correction, the boys had a mean age of 11.3 years and the girls a mean age of 10.1 years. Patients were evaluated on admission and on attaining normal occlusion. 58 boys and 63 girls participating in a growth study at Kings College School of Medicine and Dentistry, London, served as controls. RESULTS: Prior to treatment the participants suffering from Class II, Division 1 malocclusion exhibited distinct growth deficits in vertical direction. In the control group, the principal direction of mean growth was found to be anterior-inferior. Under the influence of the activator, growth was found to develop in the same direction as in the controls, so that anterior positioning of the lower jaw and an increase in lower facial height were attained.

Activator Appliances↗