Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Splints”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Comparison of a new dental trauma splint device (TTS) with three commonly used splinting techniques.

Splinting is the standard of care for stabilization of replanted or repositioned permanent teeth following trauma. The present experimental study compared four dental trauma splints in 10 volunteers. The evaluated splints included a wire-composite splint (WCS), a button-bracket splint (BS), a resin splint (RS), and a new device (TTS=Titanium Trauma Splint) specifically developed for splinting traumatized teeth. All splints were bonded to the labial surfaces of the maxillary lateral and central incisors. Splints were left in place for 1 week. After splint removal, the next splint was placed after a 1-week rest period. The sequence of splint application was randomized for each individual. The following parameters were assessed: tooth mobility with horizontal and vertical Periotest values (PTV) before and after splint application and splint removal, respectively; probing depths, plaque and bleeding on probing indices before splint application and removal, and chair time needed for splint application and removal. After splint application, horizontal PTV were significantly lower in central incisors for BS compared to TTS (P=0.04), and for RS compared to TTS (P=0.005) and to WCS (P=0.006). Reduction of lateral tooth mobility (=splint effect) expressed by the difference between horizontal pre- and postoperative PTV was significantly greater in RS compared to TTS and WCS (P<0.05) for central as well as for lateral incisors. However, changes of vertical tooth mobility were not significant across the splinting techniques. Periodontal parameters remained unchanged, reflecting the excellent oral hygiene by the study subjects. The chair time needed for splint application was significantly shorter for TTS (P<0.01). In conclusion, all tested splints appeared to maintain physiologic vertical and horizontal tooth mobility. However, the latter was critically reduced in RS splints.

Acrylic Resins↗

A comparison of immediate postreduction splinting constructs for controlling initial displacement of fractures of the distal radius: a prospective randomized study of long-arm versus short-arm splinting.

PURPOSE: To compare, in a prospective, randomized manner, the sugar tong splint with a short-arm radial gutter splint in terms of patient satisfaction and the ability to maintain reduction of distal radius fractures. METHODS: A total of 118 patients with displaced distal radius fractures were enrolled; 85 patients (85 fractures) were available for follow-up evaluation and were included in the study population. There were 26 men and 59 women with a mean age of 64 years. Thirty-eight fractures were immobilized in a short-arm radial gutter splint and 47 in a sugar tong splint. Forty fractures had a stable pattern and 45 had an unstable fracture pattern. The initial patient follow-up examination occurred a mean of 8 days after splint application. RESULTS: A total of 33 fractures showed loss of fracture reduction at the initial follow-up evaluation. Sixteen of 38 fractures immobilized with the radial gutter splint displaced, whereas displacement was seen in 17 of 47 fractures immobilized with a sugar tong splint; this difference was not significant. When the splint constructs were evaluated based on fracture stability no differences were found between the splints' ability to maintain fracture reduction in both stable and unstable displaced fractures. Patients in the short-arm radial gutter splint group had significantly better Disabilities of the Arm, Shoulder, and Hand scores than those patients whose fractures were immobilized with a sugar tong splint. CONCLUSIONS: Both the sugar tong splint and the short-arm radial gutter splint had comparable performance in maintaining the initial reduction of distal radius fractures, with the short-arm splint tolerated better by patients. Based on our study we recommend the use of a short-arm radial gutter splint for initial immobilization of displaced distal radius fractures. TYPE OF STUDY/LEVEL OF EVIDENCE: Prognostic, level II.

Adult↗

Patient preference for light-cured composite bite splint compared to heat-cured acrylic bite splint.

BACKGROUND: Heat-cured acrylic has been the most commonly used material for construction of bite splints. Although effective, its processing involves several steps and is time consuming. Furthermore, acrylic splints distort easily if not kept in water when not worn for long periods of time. A newly developed light-cured composite material is now being used for bite splint fabrication. The composite material offers benefits in ease and speed of construction, has minimal warping and distortion, and has proven patient acceptance. The aim of this study was to determine if patient satisfaction with the composite splint was as good as, or preferential to, the acrylic splint. METHODS: Both a composite and an acrylic bite splint were fabricated for each of 10 patients. The splints were worn alternately on a nightly basis and were adjusted as needed after the first week. After 3 weeks, each patient completed a questionnaire regarding the properties of each splint and any preferences they had in reference to fit, comfort, and other parameters of satisfaction. RESULTS: All of the patients were able to wear at least one of the splints comfortably. All 10 preferred the composite splint over the acrylic splint, agreeing that it felt more natural and was more comfortable to wear. CONCLUSIONS: The light-cured composite bite splint is preferable from the patient's perspective to the heat-cured acrylic bite splint. The composite splint is rapidly constructed on the original model, easily seated, and comfortably worn. Other properties of composite material also make it preferable for long-term use. Future studies are necessary to evaluate the functional differences between the composite and acrylic splint.

Acrylic Resins↗

Comfort and discomfort of dental trauma splints - a comparison of a new device (TTS) with three commonly used splinting techniques.

The present experimental study compared four dental trauma splints in 10 volunteers. The evaluated splints included a wire-composite splint (WCS), a button-bracket splint (BS), a resin splint (RS), and the newly developed titanium trauma splint (TTS). All splints were bonded to the labial surfaces of the maxillary lateral and central incisors and left in place for 1 week. After splint removal, the next splint was placed after a 1-week rest period. The sequence of splint application was randomized for each individual. The following subjective parameters were assessed using a visual analogue scale: sensitiveness of splinted teeth, irritation of the gingival margin, irritation of the lips, impairment of speech, eating and oral hygiene. The results show that the application of BS leads to a significantly higher irritation of the lips and greater impairment of speech compared to other splints (P < 0.05). The RS leads to an increased and significantly higher irritation of the gingiva (P < 0.05) owing to a significant increase in cleaning difficulties (P < 0.05). In conclusion, WCS and TTS appear to be more accepted splints according to a subjective assessment by 10 volunteers.

Acrylic Resins↗

Treatment effect on signs and symptoms of temporomandibular disorders--comparison between stabilisation splint and a new type of splint (NTI). A pilot study.

The aim of the investigation was to compare the effect on signs and symptoms of temporomandibular disorders (TMD) of two different interocclusal appliances. Thirty patients with signs and symptoms of TMD received either a stabilisation splint or a new kind of splint based on the concept of nociceptive trigeminal inhibition (NTI). A clinical examination was performed and subjective symptoms were registered before start of treatment and after 3 and 6 months. All participants were offered to change to the other type of splint at the 3-month follow-up in case of no improvement or impairment of their symptoms. One subject in each group was lost early during the investigation. The mean time for taking impressions, to make inter-occlusal recording and to adjust the stabilisation splints was 17 minutes. The mean time to fit and adjust the NTI splints was 27 minutes. At the 3-month follow-up, 4 patients that had received NTI splints accepted the offer to change to stabilisation splints due to no improvement or impairment of their symptoms. These treatments were judged as failures. No one in the stabilisation splint group utilised the offer to change treatment. At the 6-month follow-up, 7 of the remaining 10 subjects with NTI splints reported some (n = 1) or significant (n = 6) improvement, 2 reported no change and one reported impairment. All 14 who had been treated with a stabilisation splint reported some (n = 2) or significant (n = 12) improvement. For all variables registered, the results were in favour for the stabilisation splint. One subject treated with a NTI splint exhibited an impaired occlusion at the 6-month follow-up.

Adolescent↗

Nail-splinting technique for ingrown nails: the therapeutic effects and the proper removal time of the splint.

BACKGROUND: An ingrown nail is a common disorder that occurs most frequently in the great toe and causes much discomfort in patients. Although many therapeutic methods have been described, most of them can lead to severe damage to the nail or to frequent relapses. The nail-splinting technique is known to be a noninvasive therapeutic method for treating an ingrown nail. OBJECTIVE: Our purpose was to access the recurrence rate of the nail-splinting technique and to determine the proper removal time of the splint from the ingrown nail. METHODS: Fifty-seven patients with ingrown nail were treated with the nail-splinting technique. Subjects were randomized into two groups. For group 1 (28 patients), the splint was removed splint 3 days after treatment, whereas for group 2 (29 patients), the splint was removed splint 2 weeks after treatment. All patients underwent a follow-up examination at 1, 2, and 4 weeks after treatment and were evaluated for tissue status and level of pain. After 1 year, we evaluated the rate of recurrence by means of a telephone interview with each patient. RESULTS: A low recurrence rate (8.7%) for the nail-splinting technique was observed in both groups (7.1% in group 1 vs. 10.3% in group 2). The tissue status and level of pain were found to improve with time, with no statistical significance between the two groups (P> 0.05). CONCLUSION: This study indicates that the nail-splinting technique constitutes a very simple and effective, noninvasive therapeutic method for treating ingrown nail. We suggest that the 3-day nail-splinting technique is the most useful when the nail is intact or has only a slight defect.

Female↗

Treatment of joint pain and joint noises associated with a recent TMJ internal derangement: a comparison of an anterior repositioning splint, a full-arch maxillary stabilization splint, and an untreated control group.

Pain and joint noises associated with temporomandibular joint (TMJ) internal derangement are often treated by using an intra-oral splint. This study evaluated whether an anterior repositioning splint (AR splint) could be more effective in the treatment of these symptoms than a full-arch maxillary stabilization splint (FAMS splint), because of its capability to re-establish immediately the normal condyle/disk relationship. The authors treated 40 patients (average age 16.8; range 8.0-24.0) with confirmed internal derangement, joint pain, and joint noises in at least one TMJ for at least two months, with AR splint (20 subjects) or FAMS splint (20 subjects); 10 untreated patients comprised the control group. Joint noise, joint pain, and the intensity of pain were assessed using a visual analogic scale (VAS), and the pain was characterized (i.e., constant or chewing/biting pain) and evaluated monthly for eight months. Significantly fewer AR splint patients experienced pain after four months of treatment. A significantly lower intensity of pain was experienced by the AR splint patients after two months of treatment. Significantly fewer AR splint patients experienced chewing/biting pain after eight months of treatment. The frequency of joint noises decreased over time, with no significant differences between the groups. In conclusion, the AR splint seems to be more effective in decreasing pain, but it seems to make no difference in the treatment of joint noises.

Adolescent↗

Intra-articular and muscle symptoms and subjective relief during TMJ internal derangement treatment with maxillary anterior repositioning splint or SVED and MORA splints: A comparison with untreated control subjects.

Discomfort associated with wearing an intraoral splint represents a problem in the management of temporomandibular joint (TMJ) internal derangement. This study evaluated whether the use of a mandibular splint during the day and a maxillary splint at night could be more comfortable and therefore as efficacious in internal derangement treatment as a maxillary splint (AR splint). Fifty (50) patients (average age 28.8; range 14-63) with confirmed internal derangement in at least one TMJ were divided into three groups: 20 patients treated with AR splint (Group I); 20 patients treated with a SVED (Sagittal Vertical Extrusion Device) and a MORA (Mandibular Anterior Repositioning Splint) (Group II); and 10 patients who underwent no treatment (Control Group). Joint noise, pain intensity and its character (as constant or chewing/biting pain), muscular pain, and subjective relief were evaluated monthly before treatment began (T0) and for six months thereafter. The following results were found: 1. Subjects in Group I and Group II displayed a significant decrease in joint pain (p<0.001), constant pain (p<0.001), chewing/biting pain (p<0.001), joint noise and muscle pain from the beginning through the sixth month follow-ups; 2. At T1 and T2, subjects in Group II reported significantly lower discomfort associated with the devices than subjects in Group I. The use of two splints seems to be as efficacious as the use of an AR maxillary splint; however an AR splint is considered more comfortable by patients, especially during the first months of therapy.

Adolescent↗

Radiological assessment of the effects of splinting on early hip development: results from a randomised controlled trial of abduction splinting vs sonographic surveillance.

Whilst delayed treatment of fully dislocated hips diagnosed at birth prejudices final outcome, splinting clinically dislocatable hips is controversial as the majority stabilise spontaneously. Early stabilisation may not ensure normal development but even early splinting carries a small risk of avascular necrosis. We report radiological data from 76 newborns with dislocatable hips that were randomised either to immediate splinting or to sonographic surveillance which examines the influence of early splinting on hip development. Epiphyseal maturation (EM), iliac indentation (II) and acetabular angle (AA) were assessed radiographically at 6 months, blind to the treatment group; hips with normal sonograms at birth had greater EM and II and smaller AA. Whilst clinically unstable Graf type 1 and 2A hips were radiologically similar at 6 months, those splinted showed poorer EM and II compared with non-splinted hips. There were no cases of avascular necrosis. Abduction splinting may displace the femoral capital epiphysis medially resulting in poorer iliac indentation. The smaller epiphysis in splinted infants may be secondary to altered blood supply due to increased pressure between the femoral head and acetabulum and increased tension of the adductor muscles in the thigh. These differences were less marked by 1 year. Whether they have any long-term significance requires further study.

Bone Development↗

Re-emphasising the efficacy of the multi-purpose, self-adjustable, aeroplane splint for the splinting of axillary burns.

This article re-emphasises the efficacy of the previously described multi-purpose, self-adjustable, aeroplane splint for the splinting of axillary burns. This superior to the commonly used contoured splint for various reasons namely (i) its usability during the acute burn care rehabilitation, (ii) its cost effectiveness, (iii) its durability, and (iv) its strength. Above all due to its easy maneuverability this splint provides easy accessibility around environmental barriers. Though we acknowledge that there is a possibility of 'chord of circle' development due to the use of this splint, we have been successful in preventing such a complication simply by prescribing pressure garment concomitantly with this splint. Thus this article highlights the efficacy of earlier described multi-purpose, self-adjustable, aeroplane splint for the splinting of axillary burns.

Acute Disease↗

Splinting of traumatized teeth with a new device: TTS (Titanium Trauma Splint).

Displacement injuries of permanent teeth are an increasing emergency in the dental office. Children and adolescents are particularly prone to dental trauma due to participation in risky activities. Repositioning or replantation with subsequent stabilization by a dental splint is the standard of care for most displaced or avulsed permanent teeth. Non-rigid fixation allowing physiologic tooth mobility has been shown to be desirable for periodontal healing. A flexible splint of short duration appears to reduce the risk of dentoalveolar ankylosis or external replacement resorption. Different splinting techniques are currently recommended for stabilization of repositioned or replanted teeth, including a wire-composite splint, an orthodontic bracket splint or a resin splint. Each splinting option has its specific advantages and shortcomings. This paper describes a new splinting technique which offers improved comfort and handling to the patient and dentist alike.

Adult↗

The pattern of splint usage in the management of two common temporomandibular disorders. Part II: The stabilisation splint in the treatment of pain dysfunction syndrome.

OBJECTIVE: To examine whether the stabilisation splint is a suitable treatment for pain dysfunction syndrome and to determine the most appropriate pattern of usage. DESIGN: Prospective random control clinical trial. SETTING: Dental school clinic unit. SUBJECTS: 70 patients diagnosed with pain dysfunction syndrome were treated with a stabilisation splint for 3 months. Group 1 (23 patients) wore the splint 24 hours/day. Group 2 (19 patients) wore the splint only during the day. Group 3 (28 patients) wore the splint only at night. RESULTS: There was no statistically significant advantage to any pattern of splint usage; all groups showed a marked improvement by subjective and objective assessment. CONCLUSIONS: Patients being treated for pain dysfunction syndrome by a stabilisation splint need wear the splint only at night.

Adolescent↗

[Influence of the relaxation splint and stabilization splint on the EMG parameters of the masticatory muscles].

OBJECTIVE: To explore the influence of the type of occlusal splint on the masticatory muscles (TA,MM). METHODS: TA and MM EMG during ICP maximal clenching were recorded in 20 dentate normal subjects, when they weared no occlusal splint, relaxation splint and mandibular stabilization splint. RESULT: With the insertion of relaxation splint and mandibular stabilization splint, the EMG parameters of TA and MM during ICP maximal clenching was dramatically reduced (P<0.05). CONCLUSION: The relaxation splint and mandibular stabilization splint can relax the masticatory muscles.

English Abstract↗

[Marburg shoulder radiography splint (MSR splint) for standardized and high quality plain film radiography in fractures of the proximal humerus].

To ensure safe, quick, pain-relieving, standardized, and reproducible high quality plain film radiography in fractures of the proximal humerus, the MSR splint was introduced into clinical practice. With the rectangular and completely radiolucent splint the shoulder radiographs are obtained in supine position by a sole radiographer. Two radiographs are taken in projection at 90 degrees to one another: the true anteroposterior and axillary views, the most important views for fracture visualization and assessment. The smooth flat bottom part of the splint glides easily across the X-ray table below the injured shoulder. The arm lying on the chest is carefully rotated externally up to the neutral position and placed in the splint, then fixed with Velcro fastening with the forearm supinated. The splint is adjusted to the patient for the anteroposterior view which is taken with the central ray directed at the coracoid process and perpendicularly on the film cassette. For the axillary view the MSR splint holding the upper extremity is carefully swiveled into a 80-90 degrees abduction position. Even in cases of comminuted fractures this maneuver is not painful for the patients. The X-ray tube is put into a horizontal position with the central ray pointing to the humeral head in an angle about 25 degrees to the long body axis. The cassette is placed upright in touch with the shoulder girdle. In our institution the MSR splint is not only routinely used for diagnosing fractures of the proximal humerus but also for radiological follow-up controls.

Equipment Design↗

The Reel Splint: experience with a new traction splint apparatus in the prehospital setting.

A new lower extremity splint apparatus was applied by paramedics to 50 patients in the prehospital setting to manage a total of 60 injuries. The Reel Splint was designed to provide stabilization with or without traction to a variety of angulated lower extremity fractures/dislocations. In 37 instances (74%), the splint was judged by the rescuers to be superior to the standard Thomas splint. In this series the splint was used successfully for extrication , to immobilize deformed limbs, and to provide traction for the restoration and maintenance of peripheral circulation, with frequent pain relief. No deleterious functional complexities or manufacturing defects were identified. The Reel Splint is a uniquely useful alternative to currently available splints.

Allied Health Personnel↗

A comparison of two splints in the treatment of TMJ pain dysfunction syndrome. Can occlusal analysis be used to predict success of splint therapy?

Controversy surrounds the diagnosis and treatment of TMJ pain dysfunction syndrome (TMJPDS). This is also reflected in the widely divergent recommendations in splint design. A study was undertaken to examine the comparative success rates of treatment by two occlusal splints with apparently diametrically opposed modes of action and to determine whether there were any factors which could be utilised to predict the success of splint therapy. Sixty-eight TMJPDS patients were randomly distributed into one of two comparable groups and were treated solely with an occlusal splint for night time wear. One group was treated with a stabilisation splint (SS) and the other with a localised occlusal interference splint (LOIS). The success rate at review with the SS was 67.6% and with the LOIS was 80.9%. This difference was not statistically significant. Pretreatment occlusal analysis demonstrated three indicators of successful splint therapy which appeared to be independent of design. These were the absence of centric relation occlusion, the existence of non-working side interferences and an absence of ideal anterior guidance.

Chi-Square Distribution↗

To splint or not to splint--past philosophy and present practice: Part I.

The purposes of this study were to document (1) the historical use of splints, (2) record the current practice of splint application, and (3) compare splint philosophy of the past with present practice. One hundred burn references were reviewed for information on the past use of splints. Present practice was determined on the basis of a survey of 99 burn centers. Information is presented as to when splints are applied to burn patients in their course of recovery for 12 body areas prone to scar contracture. The influence of burn depth is noted. A change in the practice of applying splints to burn patients appears to have occurred. Part I of this series describes the global results and details whether splints are necessary.

Burn Units↗