Search PubMed⌕ Search

PubMed · 2002668

A lung function information system.

Abstract

A lung function information system (LFIS) was developed for the data analysis of pulmonary function tests at different locations. This system was connected to the hospital information system (HIS) for the retrieval of patient data and the storage of the lung function variables of patients to generate follow-up reports and to support financial and administrative management. The application programs were developed in such a way that high flexibility was obtained with respect to the patient-computer-technician interaction. The sampled data are stored on a disc to correct earlier decisions, perform recalculations and reanalyse the data for research purposes. When the measurements performed on a patient are authorized, the sampled data are deleted, except for when they are needed for future research. A distributed computer system was chosen to combine the benefits of a centralized system with those of several stand-alone systems. The main tasks of the central unit are to store collected data and computer programs, generate a final lung function report on laser printer and provide a connection to the HIS. In the satellite computers, which are located close to the lung function equipment, the signals and raw data are processed. Furthermore, the satellite computers were in use for program development and several research projects, and for the offline data processing of the lung function measurements from two other hospitals by means of a modem connection. The LFIS improved the quantity and quality of data acquisition. It resulted in an increased capacity of about 50% concerning spirometry, and facilitated time-consuming complex analyses. It also avoided miscalculations and mistakes in reports previously experienced with hand calculations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A F Verbraak, E Hoorn, J de Vries, J M Bogaard, A Versprille. 1991. A lung function information system.. https://doi.org/10.1016/0141-5425(91)90040-e

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗