Effects of local nerve cooling on conduction in vagal fibres shed light upon respiratory reflexes in the rabbit.

In ten vagus nerves the effect of local cooling on the compound action potential was studied in the temperature range of 34 to 0 degrees C in spontaneously breathing, anaesthetized rabbits. The mean temperature at which the myelinated (A) fibres were completely blocked, was 10.2 +/- 2.4 degrees C (mean +/- S.D.). In nine nerves, local vagus cooling to 0 degrees C failed to block all non-myelinated (C) fibres. In one nerve, total blocking occurred at 2.0 degrees C. We conclude that in the rabbit, the earlier found increase in tonic activity of the diaphragm following lung inflation or deflation during bilateral local vagus cooling to a temperature between 8 and 0 degrees C is due to afferent impulses in vagal C fibres.

Action Potentials

Serial lung model for simulation and parameter estimation in body plethysmography.

A serial lung model with a compressible segment has been implemented to simulate different types of lung and airway disorders such as asthma, emphysema, fibrosis and upper airway obstruction. The model described can be used during normal breathing, and moreover the compliant segment is structured according to more recent physiological data. A parameter estimation technique was applied and its reliability and uniqueness were tested by means of sine wave input signals. The characteristics of the alveolar pressure/flow patterns simulated with the model agree to a great extent with those found in the literature. In the case of absence of noise the parameter estimation routine produced unique solutions for different simulated pathologic classes. The sensitivity of the different parameters depended on the values belonging to each class of pathology. Some more simplified models are presented and their advantages over the complex model in special types of pathology are demonstrated. Noise added to the simulated flow appeared to have no influence on the estimated parameters, in contradiction to the effects with noise added to the pressure signal. In that case effective resistance was accurately estimated. Where parameters had no influence, as for instance upper airway resistance in emphysema or peripheral airway resistance in upper airway obstruction, the measurement accuracy was less. In all other cases, a satisfactory accuracy could be obtained.

Humans

A lung function information system.

A lung function information system (LFIS) was developed for the data analysis of pulmonary function tests at different locations. This system was connected to the hospital information system (HIS) for the retrieval of patient data and the storage of the lung function variables of patients to generate follow-up reports and to support financial and administrative management. The application programs were developed in such a way that high flexibility was obtained with respect to the patient-computer-technician interaction. The sampled data are stored on a disc to correct earlier decisions, perform recalculations and reanalyse the data for research purposes. When the measurements performed on a patient are authorized, the sampled data are deleted, except for when they are needed for future research. A distributed computer system was chosen to combine the benefits of a centralized system with those of several stand-alone systems. The main tasks of the central unit are to store collected data and computer programs, generate a final lung function report on laser printer and provide a connection to the HIS. In the satellite computers, which are located close to the lung function equipment, the signals and raw data are processed. Furthermore, the satellite computers were in use for program development and several research projects, and for the offline data processing of the lung function measurements from two other hospitals by means of a modem connection. The LFIS improved the quantity and quality of data acquisition. It resulted in an increased capacity of about 50% concerning spirometry, and facilitated time-consuming complex analyses. It also avoided miscalculations and mistakes in reports previously experienced with hand calculations.

Computer Systems

Right ventricular function assessed by thermodilution technique during apnea and mechanical ventilation.

OBJECTIVES: To evaluate strategies for thermodilution-based measurement of cardiac output and right ventricular (RV) ejection fraction and to assess the effects of controlled mechanical ventilation in patients. Furthermore, to compare strategy-associated reproducibility with reference values obtained during long-term apnea. DESIGN: Crossover trial in patients; reference values from apneic animals. SETTING: University ICU and physiology laboratory. PATIENTS: Six consecutive male ICU patients (48 to 70 yrs) after major abdominal vascular surgery. ANIMALS: two adult female sheep. INTERVENTIONS: Three ventilatory rates (8, 16, and 24 cycles/min) and 15-sec periods of apnea were selected for measurements in patients. In animals, continuous apnea was achieved with extracorporeal CO2 removal and apneic oxygenation. MEASUREMENTS: Measurements were performed using an appropriate pulmonary artery catheter and an ejection fraction/cardiac output computer prototype. The thermal indicator was injected automatically at four defined points of the ventilatory cycle, but triggered manually during apnea. MAIN RESULTS: At 8 cycles/min, there was a wide mean range of cyclic variable modulation, with a coefficient of variation of 11.6% and 23.2% for cardiac output and RV ejection fraction, respectively. Allowing for ventilatory phase or changing from 8 to 16 cycles/min reduced errors by half. Combining both procedures resulted in a coefficient of variation of 4.7% and 6.6% for cardiac output and RV ejection fraction, respectively. The best coefficient of variation values obtained during 15 secs of apnea in patients approached those variations in experimental apnea (coefficient of variation of 2.1% and 4.5% for cardiac output and RV ejection fraction, respectively). CONCLUSIONS: At low ventilatory rates, best results are achieved by averaging four phase-selected measurements. One-point measurements were less accurate and random point measurements less reproducible.

Aged

Effect of lung volume and positional changes on pulmonary diffusing capacity and its components.

Normal subjects have a larger diffusing capacity normalized per liter alveolar volume (DL/VA) in the supine than in the sitting position. Body position changes total lung diffusing capacity (DL), DL/VA, membrane conductance (Dm), and effective pulmonary capillary blood volume (Qc) as a function of alveolar volume (VA). These functions were studied in 37 healthy volunteers. DL/VA vs. VA yields a linear relationship in sitting as well as in supine position. Both have a negative slope but usually do not run parallel. In normal subjects up to 50 yr old DL/VA and DL increased significantly when subjects moved from a sitting to a supine posture at volumes between 50 and 100% of total lung capacity (TLC). In subjects greater than 50 yr old the responses of DL/VA and DL to change in body position were not significant at TLC. Functional residual capacity (FRC) decreases and DL/VA increases in all normal subjects when they change position from sitting to supine. When DL/VA increases more than predicted from the DL/VA vs. VA relationship in a sitting position, we may infer an increase in effective Qc in the supine position. In 56% of the volunteers, supine DL was smaller than sitting DL despite a higher DL/VA at FRC in the supine position because of the relatively larger decrease in FRC. When the positional response at TLC is studied, an estimation obtained accidentally at a volume lower than TLC may influence results. Above 80% of TLC, Dm decreased significantly from sitting to supine. Below this lung volume the decrease was not significant. The relationship between Qc and VA was best described by a second-order polynomial characterized by a maximum Qc at a VA greater than 60% of TLC. Qc was significantly higher in the supine position than in the sitting position, but the difference became smaller with increasing age. In observing the sitting and supine positions, we saw a decrease in maximum Qc normalized per square meter of body surface area with age.

Adolescent

Alveolar pressure during high-frequency jet ventilation.

We studied the influence of ventilatory frequency (1-5 Hz), tidal volume, lung volume and body position on the end-expiratory alveolar-to-tracheal pressure difference during high-frequency jet ventilation (HFJV) in Yorkshire piglets. The animals were anesthetized and paralysed. Alveolar pressure was estimated with the clamp off method, which was performed by a computer controlled ventilator and which had been extensively tested on its feasibility. The alveolar-to-tracheal pressure difference increased with increasing frequency and with increasing tidal volume, the common determinant appearing to be the mean expiratory flow. The effects in prone and in supine position were similar. Increasing thoracic volume decreased the alveolar-to-tracheal pressure difference indicating a dependence of this pressure difference on airway resistance. We concluded that the main factors determining the alveolar-to-tracheal pressure difference (delta P) during HFJV are expiratory flow (V'E) and airway resistance (R), delta P congruent to V'E x R.

Airway Resistance

An adequate strategy for the thermodilution technique in patients during mechanical ventilation.

The application of the thermodilution method in conditions associated with variations in blood flow implies a misuse of the Stewart Hamilton equation. Therefore, we studied the reliability of the thermodilution method for the estimation of mean cardiac output (CO) during mechanical ventilation in patients (n = 9). Variation of the injection moment in the ventilatory cycle elicited a cyclic variation of CO estimates. This variation was not the same for all patients neither in phase nor in amplitude. Therefore, no specific phase in the ventilatory cycle could be selected for an accurate estimation of mean CO. Averaging CO estimates randomly distributed in the ventilatory cycle led to an improvement of accuracy with the square root of the number of observations. The averaging of CO estimates spread equally over the ventilatory cycle led to a much better result, e.g., the variation in the average of two estimates equally spread in the ventilatory cycle was similar to the variation in the average of four random estimates. We conclude that averaging of 3 or 4 estimates spread equally over the ventilatory cycle is an adequate strategy to estimate mean cardiac output in patients reliably.

Aged

Negative effect of insufflation on cardiac output and pulmonary blood volume.

In 14 anaesthetized young pigs the changes in pulmonary blood flow and pulmonary blood volume (Qp) during mechanical ventilation were quantified. Ventilation was performed at 10 cycles per min and tidal volume (VT) was adjusted to an arterial PCO2 of about 40 mmHg (5.3 kPa). In 4 animals, 7 ventilatory cycles with an inspiratory pause (IP) of 7.2 s but different tidal volumes were inserted at intervals of 5 min to determine the decrease in Qp (delta Qp) from the differences between right ventricular (Qs,rv) and left ventricular (Qs,lv) stroke volume, and to relate delta Qp to VT. We measured pressure in the aorta (Pao), central veins (Pcv), right and left ventricles (Prv, Plv) pericardium (Pit), and trachea (PT). Blood flow was measured electromagnetically (EM) in the pulmonary artery (Q'pa) and aorta (Q'ao). Stroke volumes were derived from the EM-flow curves. In the other 10 experiments, Qs,lv was derived from the aortic pulse contour. Beat-to-beat analyses of Qs,rv and Qs,lv and blood pressures during the normal ventilatory cycles and those with an IP revealed the following: 1) The end-expiratory RV output and LV output were constant and were defined as baseline values. 2) The accumulated decrease in Qs,rv during insufflation caused a mean deficit in cardiac output of 10.3 +/- 3.2% (s.d.), n = 135; the same was found for Qs,lv, indicating the pulse contour as a useful method to estimate the variations in cardiac output during a ventilatory cycle.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

A computerized respiratory system including test functions of lung and circulation.

The design of a microcomputer-controlled ventilator for automatic performance of lung function and circulatory tests has been described. It incorporates the characteristics of normal mechanical ventilation and also allows one to perform a multitude of test procedures for lung function and circulatory studies in paralyzed animals. The major components of the setup are a pump assembly with solenoid valves to direct gas flow, an electromechanical servo system, and a MS-DOS microcomputer system. The pump assembly has been constructed as a relatively simple device. Great versatility is created by the use of a microcomputer for the control of the ventilator. The software can be easily adapted to several other types of experimental studies. Besides the keyboard input the ventilator can be controlled by a remote computer system. This allows one to run an experimental protocol automatically and to use it in closed-loop servo ventilation. The flexibility in the choice of the respiratory parameters makes the ventilator suitable for lung function and circulatory studies during artificial ventilation. The ventilator has been successfully used in different animal studies during the last 6 yr.

Animals

Exercise responses in patients with an enzyme deficiency in the mitochondrial respiratory chain.

Responses to exercise were obtained in six patients with a biochemically diagnosed enzyme deficiency at the level of NADH-CoQ reductase. The responses were compared with those of a control group, consisting of fourteen patients with inexplicable dyspnoea or muscle pain during exercise, for which no firm diagnosis could be established and of which the exercise responses were in the normal range. Metabolic, ventilatory and cardiological variables such as oxygen uptake (VO2), minute ventilation (VE), respiratory exchange ratio (R), heart rate (HR) and difference in blood lactate or base-excess (BE) between rest and maximal workload were measured during cycle ergometry from samples obtained in the last minutes of four minute periods, in which the load increased stepwise by 30 W per four minutes. The threshold of lactate metabolism (Tlact) was assumed to be equal to the threshold determined both by the VO2 at which the VE versus VO2 response started to deviate from a straight line and the ventilatory equivalent for oxygen (VE/VO2) showed a minimum (Tvent), Tvent was estimated from the mean of these values, obtained by linear and parabolic regression analysis respectively. In the patient group, mean values for symptom limited maximal VO2 (VO2,max,sl; % of VO2,max,ref), Tvent (% of VO2,max,ref) and R at maximal workload were 43, 17 and 1.23 against 85, 47 and 1.06 for the same variables in the control group, respectively. The differences were highly significant (p less than 0.001; p less than 0.005 for mean R difference). Mean maximal HR and mean change in blood lactate or BE were not significantly different in the two groups.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Suppression of spontaneous breathing during high-frequency jet ventilation. Separate effects of lung volume and jet frequency.

The effect of ventilatory frequency of high-frequency jet ventilation (HFJV) from 1 to 5 Hz, apart from changes in thoracic volume, on spontaneous breathing activity was studied in Yorkshire piglets under pentobarbital anesthesia. The highest PaCO2 at which the animals did not breathe against the ventilator (apnea point) was established either by changing minute volume of ventilation or by adding CO2 to the respiratory gas. The higher the apnea point, the higher the suppression of spontaneous breathing activity was assumed to be. If the apnea point was searched for by changing minute volume a progressive increase of suppression of spontaneous respiratory activity was found at ventilatory rates of 3 Hz or more, concomitantly with a rise in end-expiratory pressure (PEE). In case the tidal volume was kept constant, increase of ventilatory rate resulted in a tremendous increase of lung volume, together with considerably higher levels of PEE. When under these conditions the apnea point was searched for by adding CO2 to the respiratory gas a much higher CO2-drive was needed for spontaneous breathing and therefore a much stronger inhibition of spontaneous breathing was concluded. By placing the animals in a body box in which pressure could be varied, thoracic volume could be kept constant during HFJV. When thoracic volume was kept constant in this way a constant tidal volume at increasing jet frequencies resulted in only a slight increase in suppression of spontaneous breathing. We conclude that the increase in lung volume is a major factor in suppressing central respiratory activity during HFJV. Jet frequency by itself might be an additional suppressive factor.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

A simple and accurate automated system for continuous long-term metabolic studies during artificial ventilation.

Energy expenditure and the amount of metabolised carbohydrate, protein and lipid can be calculated from the O2 consumption, CO2 production and nitrogen excretion using indirect calorimetry. A low-cost automatic system has been developed suitable for short- and long-term measurements during artificial ventilation, in which the gas analysers were calibrated automatically every 10 min and in which the desired variables were calculated and printed every 5 min. O2 and CO2 concentrations of mixed expired and inspiratory gas, the expired minute volume VE, and patient's rectal temperature, were sampled at regular time intervals and a simple programmable calculator with printer was used for the on-line data analysis. Tests on accuracy, stability, reproducibility and feasibility showed this system to be suitable for clinical application.

Autoanalysis

Maximal expiratory and inspiratory flow-volume curves in bilateral vocal-cord paralysis. Changes after surgical treatment and comparison with glottic resistance characteristics.

The maximal expiratory flow-volume (MEFV) and maximal inspiratory flow-volume (MIFV) curve present maximal attainable flows, plotted against the displaced volume at the mouth during a forced expiratory manoeuvre from total lung capacity (TLC) and a subsequent forced inspiratory manoeuvre from residual volume (RV), respectively. Depending on the glottic resistance characteristics, the usual flow limitation may be absent during forced expiration, drastically influencing the form of MEFV curves. During forced inspiration however, the flow remains effort-dependent. We tested this hypothesis by comparing the form of MEFV and MIFV curves, and the glottic resistance characteristics, before and after an endolaryngeal superolateralization of a vocal cord, in 12 patients with bilateral vocal-cord paralysis. Peak expiratory and inspiratory flows were estimated with the aid of the measured glottic resistance characteristics on the assumption that the maximal alveolar pressures were normal during the manoeuvres. The estimated values agreed well with measured values. The form of the MEFV and MIFV curves was also found to be closely linked to the glottic resistance characteristics. It is concluded that the MEFV and MIFV curves are sensitive indicators of flow limitation in patients with upper-airway obstructions.

Adult

Flow limitation in upper-airway obstruction. Theoretical analysis.

During a maximal forced expiration from total lung capacity (TLC) in normal human subjects flow limitation will occur (i.e., the flow will become independent of muscular effort) after the initial part of the expiratory manoeuvre. Flow limitation starts at the flow that causes a pressure drop in the bronchial tree large enough for the generation of a flow-limiting segment. In patients with upper-airway obstruction such as laryngeal obstruction or tracheal stenosis, the upper-airway resistance may keep the flow so low that flow limitation cannot arise. The present theoretical study confirms that glottic resistance does not prevent flow limitation from arising in normal human subjects. On the other hand, the mean glottic resistance characteristics measured for 19 patients with bilateral vocal-cord paralysis were found to be such as to prevent flow limitation. This means that in such patients and also in patients with other types of upper-airway obstruction flow may remain effort-dependent throughout the forced expiratory manoeuvre or in any case during much more of this manoeuvre than normal.

Airway Resistance

Suppression of spontaneous breathing during high-frequency jet ventilation. Influence of dynamic changes and static levels of lung stretch.

Conditions which suppress spontaneous breathing activity during high-frequency jet ventilation (HFJV) were analysed in Yorkshire piglets under pentobarbital anesthesia. The highest PaCO2 at which the animals did not breathe against the ventilator (apnea point) was established during different patterns of ventilation, either by changing the minute volume or by adding CO2 to the inspiratory gas. Arterial oxygen tension was maintained throughout the study above 80 mm Hg. An elevation of ventilatory rate increased the apnea point, suggesting a progressive suppression of spontaneous breathing. This suppression did not depend on the amount of lung stretch during insufflation, because at higher rates lower tidal volumes were used. Suppression also appeared to be independent of insufflatory flow, i.e. the velocity of lung stretch. At higher frequencies end-expiratory airway pressure (PEE) increased and there appeared to be a positive relationship between the apnea point and PEE. In a separate series this positive relationship between the apnea point and PEE was confirmed. A hysteresis effect in this relationship, however, suggests that other than jet frequency, lung volume rather than positive end-expiratory pressure (PEEP) is a major determinant of suppression of spontaneous breathing activity during HFJV.

Animals