PubMed · 1739286
Burn depth estimation using indocyanine green fluorescence.
Abstract
Expedient primary excision of deep dermal and full-thickness burn wounds with subsequent skin grafting is the standard of care in most burn institutions, but differentiating full-thickness from partial-thickness burns is often difficult. Because accurate early assessment of burn depth may improve care, a variety of technical methods have attempted to measure burn depth but these methods have had limited success. We describe a new technique to determine burn depth that uses infrared (840- to 850-nm) fluorescence emission from intravenously administered indocyanine green following excitation with infrared (780 nm) and UV light (369 nm). Full-thickness and partial-thickness burns in hairless rat skin were distinguished based on the infrared-induced and UV-induced fluorescence intensity ratios relative to normal, unburned skin immediately after the burn and on post-burn days 1 through 3 and 7. Dual-wavelength excitation of indocyanine green infrared fluorescence can delineate full-thickness from partial-thickness burns at an early date, allowing prognosis, surgical planning, and early primary excision and grafting.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
H A Green, D Bua, R R Anderson, N S Nishioka. 1992. Burn depth estimation using indocyanine green fluorescence.. https://searchpubmed.org/record/pubmed%3A1739286/burn-depth-estimation-using-indocyanine-green-fluorescence
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.