Search PubMed⌕ Search

PubMed · 16877065

Vision function versus vision testing.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roger F Steinert. 2006. Vision function versus vision testing.. https://doi.org/10.1016/j.ophtha.2006.03.060

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

KLF5 promotes proliferation, migration, and autophagy-/EMT‑associated molecular changes in lens epithelial cells via transcriptional activation of THBS1 in traumatic cataract.

PURPOSE: Traumatic cataract is a common blinding eye disease after ocular trauma, and its pathogenesis is closely related to lens epithelial cell dysfunction, while the definite molecular regulatory mechanism between upstream transcription factor and downstream target gene remains poorly clarified. This study aimed to clarify the role and molecular mechanism of the krüppel-like factor 5 (KLF5)/ thrombosponin 1 (THBS1) axis in regulating proliferation, migration, epithelial-mesenchymal transition and autophagy of lens epithelial cells in traumatic cataract, and to explore its potential clinical therapeutic value. METHODS: The GSE295383 dataset in the gene expression omnibus (GEO) database was downloaded, and the differentially expressed genes (DEGs) were screened by linear models for microarray data (limma) package of R language. Combined with Weighted gene co-expression network analysis (WGCNA), the gene co-expression network was constructed and the key modules were screened. Gene ontology (GO), kyoto encyclopedia of genes and genomes (KEGG) and gene set enrichment analysis (GSEA) combined with human transcription factor target (hTFtarget) and JASPAR databases were used to predict the upstream transcription factors of THBS1. Subsequently, SRA01/04 cells were induced with transforming growth factor-beta 2 (TGF-β2) to construct a cataract cell model. RESULTS: THBS1 and KLF5 were highly expressed in LECs exposed to TGF-β2. KLF5 could activate THBS1 transcription by binding to THBS1 promoter - 174 to -165 sites. Knockdown of THBS1 inhibited TGF-β2-induced viability, proliferation, migration, and altered the expression of epithelial-mesenchymal transition (EMT)- and autophagy-related markers in LECs. Knockdown of KLF5 downregulated THBS1 expression and produced a similar inhibitory effect, while overexpression of THBS1 reversed the effect of KLF5 knockdown. CONCLUSIONS: This study demonstrated that KLF5 promoted the proliferation, migration, and EMT‑associated molecular changes of LECs in traumatic cataract through transcriptional activation of THBS1, and regulated the expression of autophagy‑related markers in LECs, suggesting that KLF5/THBS1 axis might be a potential target for the treatment of traumatic cataract.

Cataract↗

Comparison of higher-order aberrations and contrast sensitivity between Tecnis Z9001 and CeeOn 911A intraocular lenses: a prospective randomized study.

BACKGROUND: The advent of wavefront technology in the past five years has provided some insight into the optical outcomes of cataract surgery. The Tecnis Z9001 intraocular lens (Tecnis IOL, AMO) with a modified prolate anterior surface was claimed to reduce or even eliminate ocular spherical aberration to improve the visual quality. The purpose of this study was to determine whether Tecnis IOLs can improve the quality of vision as evaluated by measuring visual acuity, wavefront aberration, and contrast sensitivity. METHODS: In an intraindividual prospective study, 20 patients with bilateral cataract were randomly assigned to receive a modified prolate anterior surface IOL (Tecnis Z9001, AMO) in one eye and a biconvex spherical surface IOL (CeeOn 911A, AMO) in the other. After 3 months, the following were investigated: best corrected visual acuity, pupil diameter, photopic and mesopic contrast sensitivity, and wavefront aberration of the whole eye (ocular), cornea, and internal plane. RESULTS: The differences in the best corrected visual acuity and pupil diameter between the two groups were not statistically significant. Negative 4th-order spherical aberration (Z(4)(0)) was found in the Tecnis group, whereas positive Z(4)(0) found in the CeeOn group for the internal and ocular plane. Statistically significant differences were found at the ocular higher-aberrations between the two IOLs. Contrast sensitivity testing showed significantly better results in the Tecnis group at visual angles higher than 1.0 degree under photopic conditions and at visual angles higher than 1.6 degree under mesopic conditions both without glare and with glare in comparison with the CeeOn group. CONCLUSIONS: The Tecnis Z9001 IOL with a modified prolate anterior surface produces negative spherical aberration and consequently reduces the higher-order aberrations in pseudophakic eyes. This leads to enhanced contrast sensitivity and improved functional vision compared to conventional spherical IOLs.

Cataract↗