Search PubMed⌕ Search

PubMed · 16284665

All-solid-state reference electrodes based on conducting polymers.

Abstract

A novel construction of solution free (pseudo)reference electrodes, compatible with all-solid-state potentiometric indicator electrodes, has been proposed. These electrodes use conducting polymers (CP): polypyrrole (PPy) or poly(3,4-ethylenedioxythiophene) (PEDOT). Two different arrangements have been tested: solely based on CP and those where the CP phase is covered with a poly(vinyl chloride) based outer membrane of tailored composition. The former arrangement was designed to suppress or compensate cation- and anion-exchange, using mobile perchlorate ions and poly(4-styrenesulfonate) or dodecylbenzenesulfonate anions as immobilized dopants. The following systems were used: (i) polypyrrole layers doped simultaneously by two kinds of anions, both mobile and immobilized in the polymer layer; (ii) bilayers of polypyrrole with anion exchanging inner layer and cation-exchanging outer layer; (iii) polypyrrole doped by surfactant dodecylbenzenesulfonate ions, which inhibit ion exchange on the polymer/solution interface. For the above systems, recorded potentials have been found to be practically independent of electrolyte concentration. The best results, profound stability of potentials, have been obtained for poly(3,4-ethylenedioxythiophene) or polypyrrole doped by poly(4-styrenesulfonate) anions covered by a poly(vinyl chloride) based membrane, containing both anion- and cation-exchangers as well as solid potassium chloride and silver chloride with metallic silver. Differently to the cases (i)-(iii) these electrodes are much less sensitive to the influence of redox and pH interferences. This arrangement has been also characterized using electrochemical impedance spectroscopy and chronopotentiometry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anna Kisiel, Honorata Marcisz, Agata Michalska, Krzysztof Maksymiuk. 2005-10-27. All-solid-state reference electrodes based on conducting polymers.. https://doi.org/10.1039/b510868c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mathematical modeling of elution curves for a protein mixture in ion exchange chromatography and for the optimal selection of operational conditions.

Elution curves in ionic exchange chromatography (IEC) for a three-protein mixture (alpha-lactoalbumin, ovalbumin, and beta-lactoglobulin), carried out under different flow rates and ionic strength conditions, were simulated using two different mathematical models. These models were the Plate Model and the more fundamentally based Rate Model. Relatively low protein concentrations were used to avoid protein-protein interactions. Simulated elution curves were compared with experimental data not used for parameter identification. Deviation between experimental data and the simulated curves using the Plate Model was less than 0.0189 (absorbance units); a slightly higher deviation [0.0252 (absorbance units)] was obtained when the Rate Model was used. A cost function was built that included the effect of the different production stages, namely fermentation, purification, and concentration. These considered the effect on the performance of IEC; yield, purity, concentration and the time needed to accomplish the separation. Operational conditions in the IEC such as flow rate, ionic strength gradient and the operational time can be selected using this model in order to find the minimum cost for the protein production process depending on the characteristics of the final product desired such as purity and yield. This cost function was successfully used for the selection of the operational conditions as well as the fraction of the product to be collected (peak cutting) in IEC. It can be used for protein products with different characteristics and qualities, such as purity and yield, by choosing the appropriate parameters.

Chromatography, Ion Exchange↗

Structural characterisation of novel lichen heteroglycans by NMR spectroscopy and methylation analysis.

Two galactofuranomannans, Ths-4 and Ths-5, were isolated from the lichen, Thamnolia vermicularis var. subuliformis, using ethanol fractionation and anion-exchange and size-exclusion chromatography. The average molecular weights of Ths-4 and Ths-5 were estimated to be 19 and 200 kDa, respectively. Structural characterisation of Ths-4, Ths-5 and their partially hydrolysed derivatives was performed by methanolysis and methylation analysis. The intact and partially hydrolysed Ths-4 was further analysed using NMR spectroscopy (1D, COSY, NOESY, TOCSY, HSQC and HMBC). According to the data obtained, the heteroglycans Ths-4 and Ths-5 have similar structures, but have large differences in molecular weight. The structure is composed of 3-O-linked and 5-O-linked galactofuranosyl chains linked to a mannan core. The mannan core consists of a main chain of alpha-(1-->6)-linked mannopyranosyl residues, substituted at O-2 with either a single alpha-mannopyranosyl unit or an alpha-Manp-(1-->2)-alpha-Manp-(1-->2)-alpha-Manp group in the ratio of approximately 1:3, respectively. The polysaccharides have idealised repeating blocks as is shown.

Chromatography, Ion Exchange↗

Lab-on-a-chip technology for determination of protein isoform profiles.

A novel lab-on-a-chip technique for rapid (<15 min) and quantitative isoform-profile determination is presented. Ion-exchange chromatographic separation of protein-isoforms and a sensitive immunoassay detection are combined in a porous monolith chip. Thin lines of immobilized antibodies are used for specific capturing of target molecules, which can be detected by the reaction with antibodies bound to carbon black nano-strings. The bound carbon black is quantified by the use of an image scanner. As demonstrated with transferrin isoforms, differing only by 0.1 pH unit in their pI, this technology can distinguish minor differences in protein carbohydrate structure and enable specific determination of proteins in a complex environment, requiring only a few picogram of isoform for detection.

Chromatography, Ion Exchange↗