Search PubMed⌕ Search

PubMed · 16178809

High throughput sonication: evaluation for compound solubilization.

Abstract

Dissolution of organic compounds in DMSO in HTS plate or tube format is a difficult problem as users move to higher compression plate formats. Precipitation of compounds from DMSO screening stocks is a recognized problem in the HTS materials management process. The adverse effect of freeze thaw cycles on DMSO stock solutions stored in plate format as a result of cherry picking operations has led to the gradual replacement of plate-based storage with tube-based storage so as to minimize the number of freeze thaw cycles. Compound solubility in DMSO is markedly decreased by uptake of small quantities of water. We attribute this effect to the non ideal properties of DMSO water mixtures such that cavity formation in solvent, a necessary step in dissolution, is more difficult in wet DMSO than in dry DMSO or in pure water. We report here that efficient compound dissolution is possible even in 384 well format by the use of in-well plate-based sonication. Surprisingly, compounds precipitated from DMSO stocks either by water uptake or repeated freeze thaw cycles can be re-dissolved by low energy sonication. Finally, we demonstrate that precipitation of compound from DMSO stock solutions is synergistically enhanced by water uptake into DMSO compound stock solutions as well as by increasing the number of freeze thaw cycles.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kevin Oldenburg, Douglas Pooler, Kurt Scudder, Christopher Lipinski, Michele Kelly. 2005. High throughput sonication: evaluation for compound solubilization.. https://doi.org/10.2174/1386207054867364

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Complex adaptive systems: a response to Luchins.

Luchins (2003, Administration and Policy in Mental Health, 31(2), 183-186) distinguishes the mutual strengths and shortcomings of qualitative and quantitative approaches as applied to the complexities of evaluation psychiatric hospital functioning in particular, and behavioral healthcare practice in general. This brief response offers an examination of the complex interplay of factors within non-linear models in a conceptualization of complex adaptive systems for understanding causal factors in mental health administration as well as calling into question the myth of the relationship between measurement and hence control and understanding and prediction.

Evaluation Studies as Topic↗

[Performance evaluation of computed tomography with equivalent resolution images].

A method of evaluating the performance of computed tomography (CT) with equivalent resolution images was investigated. Generally, in performance evaluations of CT, the resolution property is measured by the wire method, and the noise property is measured from noise images of a cylindrical water phantom. The signal-to-noise ratio (SNR) is then calculated for the integrated evaluation. Our proposed method enabled perceptual integrated evaluation by using equivalent resolution images created with frequency processing. The frequency-processing factor was calculated from the ratio of the modulation transfer factors of two models of CT, and the image of one of the two was processed by the factor. Because these processed images have resolution equivalent to images of the other CT, the perceptual evaluation with noise images becomes effective. In this investigation, images of a water phantom and a middle contrast resolution phantom were employed. Perceptual comparison of the amount of noise with equivalent resolution images could be performed easily, and effective performance evaluation was achieved. Therefore, our proposed method is useful for noise property and performance evaluation of CT.

Evaluation Studies as Topic↗

Evaluation of municipal wastewater treatment plants with different technologies at Las Rozas, Madrid (Spain).

Eight small-scale municipal wastewater treatment plants were evaluated over a period of 19 months in the suburb of Las Rozas in Madrid (Spain). Four plants used compact extended aeration, two used conventional activated sludge, two used conventional extended aeration, one used a rotary biodisc reactor and the other used a peat bed reactor. The best results were obtained from the plants that used conventional technologies and the biodisc. Conventional activated sludge and extended aeration had higher removal efficiencies for ammonia, TSS, COD and BOD(5) and produced good quality final effluents for final disposal in accordance with the discharge standard. Empirical equations that correlated the concentration of dissolved oxygen in the effluents with the efficiencies of TSS, ammonia, COD and BOD(5) removals for all plants evaluated were obtained. The performance of the plants using compact extended aeration was affected more than those using conventional technologies or rotary biodisc when the capacity exceeded that of its initial design.

Evaluation Studies as Topic↗