Search PubMed⌕ Search

PubMed · 16119721

Evolution of cemented stems.

Abstract

John Charnley was responsible for pioneering successful cemented hip arthroplasty. Changes in stem design were made in response to early complications such as stem fracture. Various philosophies of stem biomechanics emerged, namely stems performing in the taper slip mode and stems performing as a composite beam. Both stem designs may be successful, although it is important not to mix biomechanical philosophies. Later evolutions have occurred in response to surgical flexibility, specifically modularity and offset options. These attributes can impart new demands on the stem and, in some cases, retrograde developments have occurred. Cemented stems may yield excellent long-term results and have the potential to limit fixation to the proximal femur and establish a metaphyseal-loading regimen. The latest design of taper slip stems, such as the C-stem (DePuy Orthopaedics, Warsaw, Ind), may have advantages in maintaining proximal bone stock and preserving host bone. The historical developments and evolution of the cemented stem in total hip arthroplasty (THA) are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nikhil Shah, Martyn Porter. 2005. Evolution of cemented stems.. https://doi.org/10.3928/0147-7447-20050802-04

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Contraction force specificity and its relationship to functional performance.

Best practice for improving strength and power through resistance strength training has been the subject of much research and subsequent conjecture. Much of the conjecture can be attributed to methodological discrepancies. The type of dynamometry used in testing, the training experience of research participants, the specific technique employed in a lift, and the methods of collection and calculation all impact on the final variables of interest. This review examines contraction force specificity by first addressing the methodological issues surrounding our interpretation of the results. Then we address the kinematics and kinetics associated with single and multiple repetitions in relation to the development of strength, power, and functional performance. This discussion provides the delimitations for analysis of subsequent training studies. Finally, recommendations are formulated with the aim of assisting assessment and training practice as well as providing directions for future research. The results of this review suggest that the enhancements in performance resulting from resistance training are context specific in experienced resistance-trained participants. Thus, specific conditioning could be required to achieve improvements in functional performance in this group.

Biomechanical Phenomena↗

Energy absorption characterization of human enamel using nanoindentation.

Enamel is a natural composite, which has much higher toughness than its major component, crystalline hydroxyapatite. In this study, the energy absorption behavior of human sound enamel was investigated with nanoindentation techniques. A UMIS nanoindenter system as well as a Berkovich and two spherical indenters with nominal tip radii of 5 and 20 microm were used to indent enamel at different loading forces in the direction parallel to enamel prisms. Inelastic energy dissipation versus depth of indenter penetration (U%-h(p) curve) as well as a function of indentation strain (U%-epsilon curve) of enamel was determined. Enamel showed much higher energy absorption capacity than a ceramic material with equivalent modulus (fused silica). Even at the lowest forces (1 mN) for the 20 microm indenter, inelastic response was found. Additional tests done at different force loading rates illustrated that load rate has little influence on P-h response of enamel. The top surface of enamel has the plastic work of indentation of approximately 5.2 nJ/microm(3). The energy absorbing ability is influenced by the very small protein rich component that exists between the hydroxyapatite nanocrystals as well as within the sheath structure surrounding the enamel rods.

Biomechanical Phenomena↗

Finite element analysis of a transmandibular implant.

Finite element analysis (FEA) was used to study the influence of bony height and baseplate effect on the transmandibular implant (TMI). FEA was used to assess the stress distribution in the mandible, with and without a baseplate. Forces were applied to the center of a bar space. The von Mises stress (SEQV) was displayed in bone, and shear stress also was measured. Tensile stress was always seen at the so-called saddle area; compressive stress was seen at the inferior border. Tensile strain at the saddle area of a 6-mm height mandible is always 9.1 times greater (corresponding to more SEQV) than that of an 18-mm mandible. At same bone heights, saddle area stresses are similar with or without a baseplate. However, stress at the lateral transossseous post interface with bone was significantly different between different bone height groups. Shear stress around the lateral transossseous post was smaller than does the SEQV of the same site. Decreased bone height dramatically increases stress at the saddle area independent of the baseplate presence. These data suggest that bone apposition is found in the severely atrophic mandibles. Thus, there is no need for a baseplate in a slight to mild atrophic mandible.

Biomechanical Phenomena↗