Search PubMed⌕ Search

Biomedical subjects

John T McDevitt

Publications and source records attributed to John T McDevitt.

14 recordsLinked to original sources

A differential array of metalated synthetic receptors for the analysis of tripeptide mixtures.

A novel library of resin-bound receptors within a cross-reactive differential array for the identification and discrimination of tripeptides and tripeptide mixtures is reported. Pattern recognition using principal component analysis showed complete discrimination of four similar tripeptides and three tripeptide mixtures. The library is comprised of a Cu(II)-centered core with two proximally appended tripeptide arms emanating outward. One tripeptide arm was prepared using combinatorial chemistry to generate the differential nature of the library. Thirty resin-bound receptors were randomly selected from the library and placed within a silicon microchip array that included integrated microfluidics elements, and an indicator-uptake assay was used for colorimetric signaling. The indicator Orange G yielded an accurate measure of the degree of association between receptors and analytes as determined by kinetic analysis of the indicator-uptake assays. Within this paper we detail the method used for differential sensing using a novel receptor library. This work further demonstrates the power and utility of a differential array of synthetic receptors for identification and discrimination of complex bioanalytes.

Amino Acid Sequence↗

A microchip CD4 counting method for HIV monitoring in resource-poor settings.

BACKGROUND: More than 35 million people in developing countries are living with HIV infection. An enormous global effort is now underway to bring antiretroviral treatment to at least 3 million of those infected. While drug prices have dropped considerably, the cost and technical complexity of laboratory tests essential for the management of HIV disease, such as CD4 cell counts, remain prohibitive. New, simple, and affordable methods for measuring CD4 cells that can be implemented in resource-scarce settings are urgently needed. METHODS AND FINDINGS: Here we describe the development of a prototype for a simple, rapid, and affordable method for counting CD4 lymphocytes. Microliter volumes of blood without further sample preparation are stained with fluorescent antibodies, captured on a membrane within a miniaturized flow cell and imaged through microscope optics with the type of charge-coupled device developed for digital camera technology. An associated computer algorithm converts the raw digital image into absolute CD4 counts and CD4 percentages in real time. The accuracy of this prototype system was validated through testing in the United States and Botswana, and showed close agreement with standard flow cytometry (r = 0.95) over a range of absolute CD4 counts, and the ability to discriminate clinically relevant CD4 count thresholds with high sensitivity and specificity. CONCLUSION: Advances in the adaptation of new technologies to biomedical detection systems, such as the one described here, promise to make complex diagnostics for HIV and other infectious diseases a practical global reality.

Algorithms↗

Membrane-based on-line optical analysis system for rapid detection of bacteria and spores.

We report here the adaptation of our electronic microchip technology towards the development of a new method for detecting and enumerating bacterial cells and spores. This new approach is based on the immuno-localization of bacterial spores captured on a membrane filter microchip placed within a flow cell. A combination of microfluidic, optical, and software components enables the integration of staining of the bacterial species with fully automated assays. The quantitation of the analyte signal is achieved through the measurement of a collective response or alternatively through the identification and counting of individual spores and particles. This new instrument displays outstanding analytical characteristics, and presents a limit of detection of approximately 500 spores when tested with Bacillus globigii (Bg), a commonly used simulant for Bacillus anthracis (Ba), with a total analysis time of only 5 min. Additionally, the system performed well when tested with real postal dust samples spiked with Bg in the presence of other common contaminants. This new approach is highly customizable towards a large number of relevant toxic chemicals, environmental factors, and analytes of relevance to clinical chemistry applications.

Bacillus↗

Disposable polydimethylsiloxane/silicon hybrid chips for protein detection.

This paper presents disposable protein analysis chips with single- or four-chamber-constructed from poly(dimethylsiloxane) (PDMS) and silicon. The chips are composed of a multilayer stack of PDMS layers that sandwich a silicon microchip. This inner silicon chip features an etched array of micro-cavities hosting polymeric beads. The sample is introduced into the fluid network through the top PDMS layer, where it is directed to the bead chamber. After reaction of the analyte with the probe beads, the signal generated on the beads is captured with a CCD camera, digitally processed, and analyzed. An established bead-based fluorescent assay for C-reactive protein (CRP) was used here to characterize these hybrid chips. The detection limit of the single-chamber protein chip was found to be 1 ng/ml. Additionally, using a back pressure compensation method, the signals from each chamber of the four-chamber chip were found to fall within 10% of each other.

C-Reactive Protein↗

Application of microchip assay system for the measurement of C-reactive protein in human saliva.

In the last decade, saliva has been advocated as a non-invasive alternative to blood as a diagnostic fluid. However, use of saliva has been hindered by the inadequate sensitivity of current methods to detect the lower salivary concentrations of many constituents compared to serum. Furthermore, developments in the areas related to lab-on-a-chip systems for saliva-based point of care diagnostics are complicated by the high viscosity and heterogeneous properties associated with this diagnostic fluid. The biomarker C-reactive protein (CRP) is an acute phase reactant and a well-accepted indicator of inflammation. Numerous clinical studies have established elevated serum CRP as a strong, independent risk factor for the development of cardiovascular disease (CVD). CVD has also been associated with oral infections (i.e. periodontal diseases) and there is evidence that systemic CRP may be a link between the two. Clinical measurements of CRP in serum are currently performed with "high sensitivity" CRP (hsCRP) enzyme-linked immunosorbent assay (ELISA) tests that lack the sensitivity for the detection of this important biomarker in saliva. Because measurement of salivary CRP may represent a novel approach for diagnosing and monitoring chronic inflammatory disease, including CVD and periodontal diseases, the objective of this study was to apply an ultra-sensitive microchip assay system for the measurement of CRP in human saliva. Here, we describe this novel lab-on-a-chip system in its first application for the measurement of CRP in saliva and demonstrate its advantages over the traditional ELISA method. The increased sensitivity of the microchip system (10 pg ml(-1) of CRP with 1000-fold dilution of saliva sample) is attributed to its inherent increased signal to noise ratio, resulting from the higher bead surface area available for antigen/antibody interactions and the high stringency washes associated with this approach. Finally, the microchip assay system was utilized in this study to provide direct experimental evidence that chronic periodontal disease may be associated with higher levels of salivary CRP.

C-Reactive Protein↗

A microbead array chemical sensor using capillary-based sample introduction: toward the development of an "electronic tongue".

The development of a micromachined fluidic structure for the introduction of liquid samples into a chip-based sensor array composed of individually addressable polymeric microbeads is presented. The micromachined structure consists of micromachined storage cavities combined with a covering glass layer that confines the microbeads and fluidic channels. In our sensor array transduction occurs via optical (colorimetric and fluorescence) changes to receptors and indicator molecules that are covalently attached to termination sites on the polymeric microbeads. Spectral data are acquired for each of the individual microbeads using a charged-coupled device (CCD) allowing for the near-real-time analysis of liquid sample. Hence the micromachined fluidic structure must allow for both optical access to the microbeads and fluid flow through the micromachined cavities that serve as the microreactors/analysis chambers. One of the key parts of the structure is a passive fluid introduction system driven only by capillary force. This simple means of fluid introduction realizes a compact device. The capillary flow on the inlet channel has been studied, and the responses of the microbeads (alizarin complexone) to a liquid sample have been characterized. The test results show that this system is useful in a micro-total-analysis-system (mu-TAS) and biomedical applications.

Biomimetics↗

Aptamer-based sensor arrays for the detection and quantitation of proteins.

Aptamer biosensors have been immobilized on beads, introduced into micromachined chips on the electronic tongue sensor array, and used for the detection and quantitation of proteins. Aptamer chips could detect proteins in both capture and sandwich assay formats. Unlike most protein-based arrays, the aptamer chips could be stripped and reused multiple times. The aptamer chips proved to be useful for screening aptamers from in vitro selection experiments and for sensitively quantitating the biothreat agent ricin.

Base Sequence↗

DNA hybridization and discrimination of single-nucleotide mismatches using chip-based microbead arrays.

The development of a chip-based sensor array composed of individually addressable agarose microbeads has been demonstrated for the rapid detection of DNA oligonucleotides. Here, a "plug and play" approach allows for the simple incorporation of various biotinylated DNA capture probes into the bead-microreactors, which are derivatized in each case with avidin docking sites. The DNA capture probe containing microbeads are selectively arranged in micromachined cavities localized on silicon wafers. The microcavities possess trans-wafer openings, which allow for both fluid flow through the microreactors/analysis chambers and optical access to the chemically sensitive microbeads. Collectively, these features allow the identification and quantitation of target DNA analytes to occur in near real time using fluorescence changes that accompany binding of the target sample. The unique three-dimensional microenvironment within the agarose bead and the microfluidics capabilities of the chip structure afford a fully integrated package that fosters rapid analyses of solutions containing complex mixtures of DNA oligomers. These analyses can be completed at room temperature through the use of appropriate hybridization buffers. For applications requiring analysis of < or = 10(2) different DNA sequences, the hybridization times and point mutation selectivity factors exhibited by this bead array method exceed in many respects the operational characteristics of the commonly utilized planar DNA chip technologies. The power and utility of this microbead array DNA detection methodology is demonstrated here for the analysis of fluids containing a variety of similar 18-base oligonucleotides. Hybridization times on the order of minutes with point mutation selectivity factors greater than 10000 and limit of detection values of approximately 10(-13) M are obtained readily with this microbead array system.

Base Pair Mismatch↗

Multishell microspheres with integrated chromatographic and detection layers for use in array sensors.

The development of miniaturized chromatographic systems localized within individual polymer microspheres and their incorporation into a bead-based cross-reactive sensor array platform is reported. The integrated chromatographic and detection concept is based on the creation of distinct functional layers within the microspheres. In this first example of the new methodology, complexing ligands have been selectively immobilized to create "separation" layers harboring an affinity for various metal cations. Additionally, a broadly responsive compleximetric dye is used to yield the "detection" layers that exhibit optical responses in the presence of a wide range of metal cations. Information concerning the identities and concentrations of solution-dissolved metal cations can be drawn from the temporal properties of the beads' optical responses. Varying the nature of the ligand in the separation shell yields a collection of cross-reactive sensing elements well-suited for use in array-based micrototal analysis systems. Accordingly, such beads have been incorporated into the "Electronic Taste Chip" platform and used for discriminating among aqueous metal cation solutions.

Anthraquinones↗

Differential receptors create patterns diagnostic for ATP and GTP.

Herein we report the combination of a library of resin-bound sensors along with a multicomponent sensor array. This novel combinatorial array sensor system shows selectivity for nucleotide phosphates in solution. The design of the anchored receptor includes a 1,3,5-trisubstituted-2,4,6-triethylbenzene scaffold coupled with peptide libraries. Each chemosensor is placed into a micromachined cavity within a silicon wafer, and the optical changes observed by a charged-coupled device result in near-real-time digital analysis of solutions. A colorimetric displacement assay was performed, and time-dependent imaging studies of the selected sensing ensembles result in a differential responses upon addition of adenosine 5'-triphosphate (ATP), adenosine 5'-monophosphate (AMP), or guanosine 5'-triphosphate (GTP). An advantage to this approach is that it creates an array of sensors that gives a fingerprint response for each analyte. Principal component analysis indicates that the library of chemosensors can differentiate between ATP, GTP, and AMP. On the basis of factor loading values, individual sensors from the library were sequenced to elucidate their chemical composition.

Adenosine Triphosphate↗

A microchip-based multianalyte assay system for the assessment of cardiac risk.

The development of a novel chip-based multianalyte detection system with a cardiac theme is reported. This work follows the initial reports of "electronic taste chips" whereby multiple solution-phase analytes such as acids, bases, metal cations, and biological cofactors were detected and quantitated. The newly fashioned "cardiac chip" exploits a geometry that allows for isolation and entrapment of single polymeric spheres in micromachined pits while providing to each bead the rapid introduction of a series of reagents/washes through microfluidic structures. The combination of these miniaturized components fosters the completion of complex assays with short analysis times using small sample volumes. Optical signals derived from single beads are used to complete immunological tests that yield outstanding assay characteristics. The power and utility of this new methodology is demonstrated here for the simultaneous detection of the cardiac risk factors, C-reactive protein and interleukin-6, in human serum samples. This demonstration represents the first important step toward the development of a useful cardiac chip that targets numerous risk factors concurrently and one that can be customized readily for specific clinical settings.

Blood Chemical Analysis↗