Search PubMed⌕ Search

PubMed · 15979746

Automated methods for multiplexed pathogen detection.

Abstract

Detection of pathogenic microorganisms in environmental samples is a difficult process. Concentration of the organisms of interest also co-concentrates inhibitors of many end-point detection methods, notably, nucleic acid methods. In addition, sensitive, highly multiplexed pathogen detection continues to be problematic. The primary function of the BEADS (Biodetection Enabling Analyte Delivery System) platform is the automated concentration and purification of target analytes from interfering substances, often present in these samples, via a renewable surface column. In one version of BEADS, automated immunomagnetic separation (IMS) is used to separate cells from their samples. Captured cells are transferred to a flow-through thermal cycler where PCR, using labeled primers, is performed. PCR products are then detected by hybridization to a DNA suspension array. In another version of BEADS, cell lysis is performed, and community RNA is purified and directly labeled. Multiplexed detection is accomplished by direct hybridization of the RNA to a planar microarray. The integrated IMS/PCR version of BEADS can successfully purify and amplify 10 E. coli O157:H7 cells from river water samples. Multiplexed PCR assays for the simultaneous detection of E. coli O157:H7, Salmonella, and Shigella on bead suspension arrays was demonstrated for the detection of as few as 100 cells for each organism. Results for the RNA version of BEADS are also showing promising results. Automation yields highly purified RNA, suitable for multiplexed detection on microarrays, with microarray detection specificity equivalent to PCR. Both versions of the BEADS platform show great promise for automated pathogen detection from environmental samples. Highly multiplexed pathogen detection using PCR continues to be problematic, but may be required for trace detection in large volume samples. The RNA approach solves the issues of highly multiplexed PCR and provides "live vs. dead" capabilities. However, sensitivity of the method will need to be improved for RNA analysis to replace PCR.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Timothy M Straub, Brian P Dockendorff, Maria D Quiñonez-Díaz, Catherine O Valdez, Janani I Shutthanandan, Barbara J Tarasevich, Jay W Grate, Cynthia J Bruckner-Lea. 2005. Automated methods for multiplexed pathogen detection.. https://doi.org/10.1016/j.mimet.2005.04.012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

On-line estimation of dissolved methane concentration during methanotrophic fermentations.

Knowledge of the aqueous phase methane concentration is critical to understanding and controlling process kinetics in methanotrophic bioreactors. Unfortunately since no dissolved methane probe is commercially available, this data must be obtained off-line by the time-consuming gas-liquid partition method. In this study we demonstrate how knowledge of the reactor's k(L)a for oxygen combined with gas phase methane analysis can be used to continuously estimate the aqueous phase concentration of dissolved methane. The on-line estimation was verified in two reactor systems with greatly different values of k (L)a. In both systems the measured and calculated dissolved methane concentrations were in good agreement although dissolved methane was underestimated in both cases. The utility of this methodology was demonstrated by revealing a possible metabolic bottleneck in the model system.

Automation↗

Magnetic particles for the separation and purification of nucleic acids.

Nucleic acid separation is an increasingly important tool for molecular biology. Before modern technologies could be used, nucleic acid separation had been a time- and work-consuming process based on several extraction and centrifugation steps, often limited by small yields and low purities of the separation products, and not suited for automation and up-scaling. During the last few years, specifically functionalised magnetic particles were developed. Together with an appropriate buffer system, they allow for the quick and efficient purification directly after their extraction from crude cell extracts. Centrifugation steps were avoided. In addition, the new approach provided for an easy automation of the entire process and the isolation of nucleic acids from larger sample volumes. This review describes traditional methods and methods based on magnetic particles for nucleic acid purification. The synthesis of a variety of magnetic particles is presented in more detail. Various suppliers of magnetic particles for nucleic acid separation as well as suppliers offering particle-based kits for a variety of different sample materials are listed. Furthermore, commercially available manual magnetic separators and automated systems for magnetic particle handling and liquid handling are mentioned.

Automation↗

Applications of microfluidics in chemical biology.

This review discusses the application of microfluidics in chemical biology. It aims to introduce the reader to microfluidics, describe characteristics of microfluidic systems that are useful in studying chemical biology, and summarize recent progress at the interface of these two fields. The review concludes with an assessment of future directions and opportunities of microfluidics in chemical biology.

Automation↗