Search PubMed⌕ Search

Biomedical subjects

Jay W Grate

Publications and source records attributed to Jay W Grate.

14 recordsLinked to original sources

Crosslinked enzyme aggregates in hierarchically-ordered mesoporous silica: a simple and effective method for enzyme stabilization.

alpha-chymotrypsin (CT) and lipase (LP) were immobilized in hierarchically-ordered mesocellular mesoporous silica (HMMS) in a simple but effective way for the enzyme stabilization, which was achieved by the enzyme adsorption followed by glutaraldehyde (GA) crosslinking. This resulted in the formation of nanometer scale crosslinked enzyme aggregates (CLEAs) entrapped in the mesocellular pores of HMMS (37 nm), which did not leach out of HMMS through narrow mesoporous channels (13 nm). CLEA of alpha-chymotrypsin (CLEA-CT) in HMMS showed a high enzyme loading capacity and significantly increased enzyme stability. No activity decrease of CLEA-CT was observed for 2 weeks under even rigorously shaking condition, while adsorbed CT in HMMS and free CT showed a rapid inactivation due to the enzyme leaching and presumably autolysis, respectively. With the CLEA-CT in HMMS, however, there was no tryptic digestion observed suggesting that the CLEA-CT is not susceptible to autolysis. Moreover, CLEA of lipase (CLEA-LP) in HMMS retained 30% specific activity of free lipase with greatly enhanced stability. This work demonstrates that HMMS can be efficiently employed as host materials for enzyme immobilization leading to highly enhanced stability of the immobilized enzymes with high enzyme loading and activity.

Chymotrypsin↗

Equilibration-based preconcentrating minicolumn sensors for trace level monitoring of radionuclides and metal ions in water without consumable reagents.

A sensor technique is described that captures analyte species on a preconcentrating minicolumn containing a selective solid-phase sorbent. In this approach, the sample is pumped through the column until the sorbent phase is fully equilibrated with the sample concentration, and the exit concentration equals the inlet concentration. On-column detection of the captured analytes using radiometric and spectroscopic methods is demonstrated. In trace level detection applications, this sensor provides a steady-state signal that is proportional to sample analyte concentration and is reversible. The method is demonstrated for the detection of Tc-99 using anion-exchange beads mixed with scintillating beads and light detection, Sr-90 using SuperLig 620 beads mixed with scintillating beads and light detection; and hexavalent chromium detection using anion-exchange beads with spectroscopic detection. Theory has been developed to describe the signal at equilibration and to describe analyte uptake as a function of volume and concentration, using parameters and concepts from frontal chromatography. It is shown that experimental sensor behavior closely matches theoretical predictions and that effective sensors can be prepared using low plate number columns. This sensor modality has many desirable characteristics for in situ sensors for trace level contaminant long-term monitoring where the use of consumable reagents for sensor regeneration would be undesirable. Initial experiments in groundwater matrixes demonstrated the detection of Tc-99 at drinking water level standards (activity of 0.033 Bq/mL) and detection of hexavalent chromium to levels below drinking water standards of 50 ppb.

Journal Article↗

Single-walled carbon nanotube paper as a sorbent for organic vapor preconcentration.

Single-walled carbon nanotubes were examined as an adsorptive material for a thermally desorbed preconcentrator for organic vapors. The nanotubes were processed into a paper form and packed into a metal tube for flow-through sampling. Adsorbed vapors were released by a temperature-programmed desorption method and detected downstream with a flexural plate wave vapor sensor. The tested vapors, methyl ethyl ketone, toluene, and dimethyl methylphosphonate, were released from the packed column at different temperatures. The vapors were retained more strongly than previously observed for the widely used Tenax porous polymer, indicating a significant affinity of the single walled nanotubes for organic vapors.

Journal Article↗

Progressive thermal desorption of vapor mixtures from a preconcentrator with a porous metal foam internal architecture and variable thermal ramp rates.

A vapor preconcentrator has been designed with the porous polymer (Tenax) packed into a highly porous metal foam to facilitate thermal conductivity and temperature uniformity throughout the bed of the preconcentrator during heating. Vapors were desorbed using linear temperature programming from room temperature to a maximum temperature of 170 or 200 degrees C; the programmed duration of the thermal ramp was varied from 10 to 180 s. The partial separation of vapor mixtures that are thermally desorbed from the preconcentrator has been examined in terms of a metric for resolution, using methyl ethyl ketone, toluene, and dimethyl methylphosphonate as a test mixture. Vapors desorbed as a sequence of partially separated overlapping peaks, as observed with a polymer-coated flexural plate wave sensor. It was shown that vapor mixture resolution improved as the total time of the thermal ramp was extended from 30 to 120 s. In this way, the preconcentrator serves to act as a preseparator in addition to its usual functions for sampling, signal modulation, and improving sensitivity. Overlapping peaks were modeled, and peak areas were extracted using an exponentially modified Gaussian model. Peak areas were independent of the thermal ramp rate. Uses of such preconcentrators with multivariate detectors, such as sensor arrays, are discussed.

Journal Article↗

Simple synthesis of hierarchically ordered mesocellular mesoporous silica materials hosting crosslinked enzyme aggregates.

Hierarchically ordered mesocellular mesoporous silica materials (HMMS) were synthesized using a single structure-directing agent. The mesocellular pores are synthesized without adding any pore expander; the pore walls are composed of SBA-15 type mesopores. Small-angle X-ray scattering revealed the presence of uniform pore structures with two different sizes. Using HMMS as a nanoscopic template, hierarchically ordered mesocellular mesoporous carbon (HMMC) and polymer (HMMP) materials were synthesized. HMMS was used as a host for enzyme immobilization. To improve the retention of enzymes in HMMS, we adsorbed enzymes, and then employed crosslinking using glutaraldehyde (GA). The resulting crosslinked enzyme aggregates (CLEAs) show an impressive stability with extremely high enzyme loadings. For example, 0.5 g alpha-chymotrypsin (CT) could be loaded in 1 g of silica with no activity decrease observed with rigorous shaking over one month. In contrast, adsorbed CT without GA treatment resulted in a lower loading, which further decreased due to continuous leaching of adsorbed CT under shaking. The activity of crosslinked CT aggregates in HMMS was approximately 10 times higher than that of the adsorbed CT, which represents a 74-fold increase in activity per unit weight of HMMS due to higher CT loading.

Adsorption↗

Automated methods for multiplexed pathogen detection.

Detection of pathogenic microorganisms in environmental samples is a difficult process. Concentration of the organisms of interest also co-concentrates inhibitors of many end-point detection methods, notably, nucleic acid methods. In addition, sensitive, highly multiplexed pathogen detection continues to be problematic. The primary function of the BEADS (Biodetection Enabling Analyte Delivery System) platform is the automated concentration and purification of target analytes from interfering substances, often present in these samples, via a renewable surface column. In one version of BEADS, automated immunomagnetic separation (IMS) is used to separate cells from their samples. Captured cells are transferred to a flow-through thermal cycler where PCR, using labeled primers, is performed. PCR products are then detected by hybridization to a DNA suspension array. In another version of BEADS, cell lysis is performed, and community RNA is purified and directly labeled. Multiplexed detection is accomplished by direct hybridization of the RNA to a planar microarray. The integrated IMS/PCR version of BEADS can successfully purify and amplify 10 E. coli O157:H7 cells from river water samples. Multiplexed PCR assays for the simultaneous detection of E. coli O157:H7, Salmonella, and Shigella on bead suspension arrays was demonstrated for the detection of as few as 100 cells for each organism. Results for the RNA version of BEADS are also showing promising results. Automation yields highly purified RNA, suitable for multiplexed detection on microarrays, with microarray detection specificity equivalent to PCR. Both versions of the BEADS platform show great promise for automated pathogen detection from environmental samples. Highly multiplexed pathogen detection using PCR continues to be problematic, but may be required for trace detection in large volume samples. The RNA approach solves the issues of highly multiplexed PCR and provides "live vs. dead" capabilities. However, sensitivity of the method will need to be improved for RNA analysis to replace PCR.

Automation↗

Development and evaluation of gold-centered monolayer protected nanoparticle stationary phases for gas chromatography.

The current status for the development of novel open-tubular gas chromatography (GC) stationary phases consisting of thin films of gold-centered monolayer protected nanoparticles (MPNs) is reported. Dodecanethiol MPNs, in which the monolayer is dodecanethiol linked to the gold nanoparticle, have shown great promise as a GC stationary phase with efficient columns having been produced in a variety of capillary i.d.'s with stationary phase film depths ranging from 10 to 60 nm, +/-2 nm at a given film depth. Stationary phase operational parameters are discussed including maximum operating temperature, sample capacity, and stationary phase lifetime and robustness. An overview of the general method employed for column production is also included. The sample capacity was determined for a 2.5 m, 250 microm i.d. column with a stationary phase film thickness of 40 nm, at 50 degrees C using anisole (k' = 1.86) as the probe analyte. The sample capacity was experimentally found to be 2.3 ng under these conditions, similar to values reported for thicker, polymer stationary phases. The efficiency of the dodecanethiol MPN stationary phase was determined with a 100 microm i.d. capillary and found to have a reduced plate height hmin value of 0.95 for octane (k' = 0.68). Areas of application illustrated and discussed utilizing the dodecanethiol MPN stationary phase include complementary separations such as two-dimensional GC (GC x GC), potential utilization within a model system for a micro-fabricated GC (microGC), as well as efficient single dimension high-speed separations. Initial development of polar stationary phases utilizing 4-chlorobenzenethiol MPNs and 4-(trifluoromethyl)benzenethiol MPNs is discussed. Included is a selectivity comparison of the retention behavior of the 4-chlorobenzenethiol MPN stationary phase and the dodecanethiol MPN stationary phase.

Chromatography, Gas↗

Microwave-assisted sample treatment in a fully automated flow-based instrument: oxidation of reduced technetium species in the analysis of total technetium-99 in caustic aged nuclear waste samples.

An automated flow-based instrument for microwave-assisted treatment of liquid samples has been developed and characterized. The instrument utilizes a flow-through reaction vessel design that facilitates the addition of multiple reagents during sample treatment and removal of the gaseous reaction products and enables quantitative removal of liquids from the reaction vessel for carryover-free operations. Matrix modification and speciation control chemistries that are required for the radiochemical determination of total (99)Tc in caustic aged nuclear waste samples have been investigated. A rapid and quantitative oxidation procedure using peroxydisulfate in acidic solution was developed to convert reduced technetium species to pertechnetate in samples with high content of reducing organics. The effectiveness of the automated sample treatment procedures has been validated in the radiochemical analysis of total (99)Tc in caustic aged nuclear waste matrixes from the Hanford site.

Journal Article↗

High-speed gas chromatography using synchronized dual-valve injection.

A novel injection technique for high-speed gas chromatography is demonstrated. Synchronized dual-valve injection is shown to provide peak widths as low as 1.5 ms (width at half-height) for an unretained analyte. This was achieved using a 0.5-m DB-5 column with an internal diameter of 100 microm and a film thickness of 0.4 microm operated at a temperature of 150 degrees C with a column absolute head pressure of 85 psi, resulting in a dead time of only t(o) = 26 ms ( approximately 1900 cm/s, 26 mL/min). Using the DB-5 column in a 1-m length under the same instrumental parameters, with a resulting linear flow velocity of 935 cm/s (12.7 mL/min, t(o) = 117 ms), a minimum peak width of 3.3 ms was obtained. During an isothermal separation, 10 analytes were separated in a time window of 400 ms. A rigorous comparison of experimental and theoretical band-broadening data based on the Golay equation showed that band broadening is limited almost entirely by the chromatographic band broadening terms expressed by the Golay equation and not by extra column band broadening due to the injection process. Synchronized dual-valve injection offers a rugged and inexpensive design, providing extremely reproducible injections with peak height precision of 2.4% (RSD) and low run-to-run variation in retention times, with an average standard deviation less than 0.1 ms. Herein, synchronized dual-valve injection is demonstrated as a proof of principle using high-speed diaphragm valves. It is foreseen that the injection technique could be readily implemented using a combination of thermal modulation and high-speed valve hardware, thus optimizing the mass transfer and not significantly sacrificing the limit of detection performance for high-speed GC. Further implications are that, if properly implemented, high-speed temperature programming coupled with this new technology should lead to very large peak capacities for approximately 1-s separations.

Chromatography, Gas↗

Monolayer-protected gold nanoparticles as an efficient stationary phase for open tubular gas chromatography using a square capillary model for chip-based gas chromatography in square cornered microfabricated channels.

The application of a dodecanethiol monolayer-protected gold nanoparticle (MPN) stationary phase within a microchannel environment was explored using a square capillary column as a model for high-speed, microfabricated gas chromatography (microGC). Successful deposition and evaluation of a dodecanethiol MPN phase within a 1.3 m long, 100 microm x 100 microm square capillary is reported. The thickness of the MPN phase was evaluated using SEM analysis. An average thickness of 15 nm along the capillary walls was determined. While the film depth along the walls was very uniform, the corner depths were greater with the largest observed depth being 430 nm. Overall, an efficient chromatographic system was obtained with a minimum reduced plate height, h(min), of 1.2 for octane (k = 0.22). Characterization of the MPN column was completed using four compound classes (alkanes, alcohols, ketones, and aromatics) that were used to form a seven-component mixture with a 2-s separation. A mixture consisting of a nerve agent simulant in a sample containing analytes that may commonly interfere with detection was also separated in only 2 s, much faster than a similar separation previously reported using a microGC system requiring 50 s. A comparison of the MPN stationary phase to phases employed in previously reported microGC systems is also made. Application of the square capillary MPN column for a high-speed separation as the second column of a comprehensive 2-D gas chromatography system (GC x GC) was also explored.

Chromatography, Gas↗

Monolayer-protected gold nanoparticles as a stationary phase for open tubular gas chromatography.

The use of a thin film of monolayer-protected gold nanoparticles (MPNs) as a stationary phase for gas chromatography (GC) is reported. Deposition of a MPN film was obtained in a 2-m, 530-microm-i.d. deactivated silica capillary using gravity to force the solution containing the MPN material through the capillary. By SEM analysis, the average film thickness was determined to be 60.7 nm. The retention behavior for the dodecanethiol MPN column was studied using four compound classes (alkanes, alcohols, aromatics, ketones), and retention orders were objectively compared to a commercially available column (AT-1, 100-nm film thickness). Separation of an eight-component mixture was performed using both isothermal and temperature-programming methods with the dodecanethiol MPN phase and compared to an isothermal separation with the AT-1 phase. The AT-1 phase separation had an efficiency, N, of 6200 (k' = 0.33) while the dodecanethiol MPN phase separation had an efficiency, N, of 5700 (k' = 0.21) for the same analyte, octane. The reduced plate height, h, for octane was found to be less than 1 at the optimum linear flow velocity, indicating the MPN column operated near the optimum possible performance level. Robustness of the MPN phase is also discussed with consistent performance observed over several months. Overall, MPNs appear promising as a stationary-phase material for GC and as an experimental platform to study their thermodynamic and mass-transfer properties.

Journal Article↗

Sorptive behavior of monolayer-protected gold nanoparticle films: implications for chemical vapor sensing.

Monolayer-protected gold nanoparticle materials were synthesized and characterized for use as sorptive layers on chemical sensors. Thiols investigated as monolayer-forming molecules included dodecanethiol, benzenethiol, 4-chlorobenzenethiol, 4-bromobenzenethiol, 4-(trifluoromethyl)benzenethiol, 4-hydroxybenzenethiol, and 4-aminobenzenethiol. Films of selected monolayer-protected nanoparticle (MPN) materials were deposited on thickness shear mode devices and vapor uptake properties were measured at 298 K. Many, but not all, MPN-based sensing layers demonstrated rapid and reversible uptake of vapors, and sorptive selectivity varies with the monolayer structure. The mass of vapor sorbed per mass of sorptive material was determined and compared with poly(isobutylene) and poly(epichlorohydrin) as examples of simple sorptive polymers that have been used on vapor sensors. The nanoparticle-based films considered here were less sorptive than the selected polymers on a per-mass basis. Partition coefficients, which measure the mass of vapor sorbed per volume of the sorptive phase, were estimated for these MPN materials and found to be comparable to or less than those of the polymer layers. Implications for the roles of sorption and transduction in determining the performance of chemical sensors coated with nanoparticle-based films are discussed.

Journal Article↗