Search PubMed⌕ Search

PubMed · 15847988

Continuous variation data: 1:1 or 2:2 weak complexes?

Abstract

An attempt to distinguish between 1:1 and 2: 2 weak complexes from continuous variation data is given. A modification of the Heller and Schwarzenbach's method which involves the use of the absorbance ratio y=A/A(lim) (once the limiting absorbance, A(lim) is known) may be applied to 1:1 weak complexes. This allows checking if the slope obtained is close to the theoretical value of -0.25. A curvature appears and the residuals have a pattern when a wrong 1:1 model is selected for a true 2:2 stoichiometry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ana Sayago, Maravillas Boccio, Agustin G Asuero. 2005-05-13. Continuous variation data: 1:1 or 2:2 weak complexes?. https://doi.org/10.1016/j.ijpharm.2005.01.038

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Proteasome inhibition by a totally synthetic beta-lactam related to salinosporamide A and omuralide.

A new and effective proteasome inhibitor, beta-lactam 3, has been accessed enantioselectively by multistep synthesis from the readily prepared intermediates 7 and 8 which were joined by a [2 + 2]-cycloaddition reaction to form the spiro beta-lactam 9 stereoselectively. The intermediate 9 was converted to 3 in seven steps and 30% overall yield. The beta-lactam 3 is stable for many days in water at pH 7, in contrast to the natural beta-lactones salinosporamide A (1) and omuralide (2). In common with 1 and 2, the beta-lactam 3 effectively inhibits the mammalian proteasome.

Drug Stability↗

Stability of bovine serum albumin complexed with PEG-poly(L-histidine) diblock copolymer in PLGA microspheres.

The aim of this study was to examine the stability of bovine serum albumin (BSA) in poly(DL-lactic acid-co-glycolic acid) (PLGA) microspheres upon addition of a new excipient, poly(ethylene glycol)-poly(L-histidine) diblock copolymer (PEG-PH). Poly(L-histidine) component can form an ionic complex with BSA under acidic conditions within a narrow pH range. To optimize the ionic complexation conditions for BSA with PEG-PH, the resulting complex sizes were monitored using the Zetasizer. PLGA microspheres containing BSA as a model protein were prepared by w/o/w double emulsion method. BSA stability in aqueous solutions and after release from PLGA microspheres was determined using circular dichroism (CD) spectroscopy for secondary structure analyses and fluorescence measurements for tertiary structure analyses. The release profile of BSA from the microspheres was monitored using UV spectrophotometry. The rate of PLGA degradation was monitored by gel permeation chromatography. The pH profile within microspheres was further evaluated by confocal microscopy using a pH-sensitive dye. Approximately 19 PEG-PH molecules and one BSA molecule coalesced to form an ionic complex around a pH range of 5.0-6.0. Plain BSA/PLGA and BSA/PEG-PH/PLGA microspheres had a mean size of 27-35 microm. PLGA microspheres with a BSA loading efficiency >80% were prepared using the double emulsion method. PEG-PH significantly improved the stability of BSA both in aqueous solutions and in PLGA microspheres. The release profiles of BSA from different formulations of PLGA microspheres were significantly different. PEG-PH effectively buffered the local acidity inside the microspheres and improved BSA release kinetics by reducing initial burst release and extending continuous release over a period of time, when encapsulated as an ionic complex. PLGA degradation rate was found to be delayed by PEG-PH. There was clear evidence that PEG-PH played multiple roles when complexed with BSA and incorporated into PLGA microspheres. PEG-PH is an effective excipient for preserving the structural stability of BSA in aqueous solution and BSA/PLGA microspheres formulation.

Drug Stability↗

Ionic liquid matrix-induced metastable decay of peptides and oligonucleotides and stabilization of phospholipids in MALDI FTMS analyses.

Room-temperature ionic liquid matrices (ILMs) have recently been investigated for use in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) and proven to be advantageous. Literature accounts of ILM performance for biological samples document increased sensitivity and ionization efficiency. These claims have been investigated here, and are supported for MALDI TOF applications to peptides, oligonucleotides, and phospholipids. Peptides and oligonucleotides however, do not behave in the same way when ILMs are used for MALDI FTMS. As reported here, with 3 tesla MALDI FTMS peptides and oligonucleotides fragment readily. These observations contrast with those found for MALDI time-of-flight mass spectrometry. Fragmentation is apparently slower than the time required to accelerate ions in a MALDI TOF mass spectrometer, but is readily observed by MALDI FTMS. Therefore, fragmentation of these molecules must occur on a relatively slow time scale. As trapping time is extended, increased fragmentation of peptides and oligonucleotides is seen. However, phospholipids do not fragment extensively. Furthermore, use of traditional solid matrices causes significant fragmentation for this category of compound but is suppressed by use of ILMs.

Drug Stability↗