A contribution to sonograph image quality estimation using point spread function.

Abstract

In medical sonography, sonograph image quality is an essential aspect for the safety of both patient and doctor. Its evaluation therefore requires an accurate and objective method for measurement. In this regard, a number of methods are in current use. Most of these are based on tissue mimicking phantom imaging. In contrast, we have used another principle based on Point Spread Function (PSF) analysis which is a product of the measuring system we have developed. In this case, the measured sonograph scans a small metallic ball target that moves in a water bath on a specified trajectory. The Region Of Interest (ROI) of the sonogram containing the ball target picture is digitised and the amplitude of the pixels analysed. The result is the PSF from which we calculate the lateral resolution (LR). For this purpose, we use our own original software. Using this method, we have to date been able to plot LR characteristics over the scanning plane. The method allows us to differentiate separate scanning lines and even multiple focal areas for dynamic focussing systems. It can detect malfunctions in dynamic focussing, size of aperture, time gain compensation function and/or transducer element failure. The procedure itself is not as easy or as fast to use as tissue mimicking phantoms or 3D signal to noise ratio evaluation, but it provides accurate and objective numeric parameters corresponding to the quality of image at any specified point over the whole scanning area. It is also a very powerful tool when used in combination with the other methods mentioned above.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ladislav Dolezal, Jan Hálek. 2004. A contribution to sonograph image quality estimation using point spread function.. https://pubmed.ncbi.nlm.nih.gov/15841913/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dose reduction in multidetector CT of the urinary tract. Studies in a phantom model.

A novel ureter phantom was developed for investigations of image quality and dose in CT urography. The ureter phantom consisted of a water box (14 cm x 32 cm x 42 cm) with five parallel plastic tubes (diameter 2.7 mm) filled with different concentrations of contrast media (1.88-30 mg iodine/ml). CT density of the tubes and noise of the surrounding water were determined using two multidetector scanners (Philips MX8000 with four rows, Siemens Sensation 16 with 16 rows) with varying tube current-time product (15-100 mAs per slice), voltage (90 kV, 100 kV, 120 kV), pitch (0.875-1.75), and slice thickness (1 mm, 2 mm, 3.2 mm). Contrast-to-noise ratio as a parameter of image quality was correlated with dose (CTDI) and was compared with image evaluation by two radiologists. The CT densities of different concentrations of contrast media and contrast-to-noise ratio were significantly higher when low voltages (90 kV versus 120 kV, 100 kV versus 120 kV) were applied. Smaller slice thickness (1 mm versus 2 mm) did not change CT density but decreased contrast-to-noise ratio due to increased noise. Contrast phantom studies showed favourable effects of low tube voltage on image quality in the low dose range. This may facilitate substantial dose reduction in CT urography.

Phantoms, Imaging↗

Development of a simple control system for uniform proton dose distribution in a dual-ring double scattering method.

In proton radiotherapy with high focusing of irradiation on the tumour, it is important to obtain treatment beams with a highly uniform dose distribution. Uniform dose distribution in the clinical irradiation field can be obtained by the dual-ring double scattering method. This method is superior to the wobbler method, which uses electromagnetic deflection of the proton beams, because of the absence of the temporal structure of irradiation distribution. However, in the dual-ring double scattering method the condition of incident proton beams entering the scatter, especially the accuracy of the position of the incident proton beams with respect to the scatter, markedly affects the uniformity of the beam distribution in the irradiation field. In this study, to ensure the uniformity of dose distribution during treatment, we developed a control system equipped with an automatic fine adjustment of the beam axis and a mechanism for moving the second dual-ring scatter of the double scatters to the optimal position. Using this system, we achieved uniform dose distribution in the irradiation field during proton radiotherapy, with symmetry within +/-1% and flatness within 2%.

Phantoms, Imaging↗

Trends in image quality in high magnification digital specimen cabinet radiography.

Advances in microfocus X-ray tube design together with the availability of high resolution charge coupled device (CCD) detectors have led to the introduction of high magnification digital specimen cabinets for the examination of tissue samples. This paper explores the effect that the high magnification geometry permitted by such units has upon image quality in terms of phase contrast edge enhancement, spatial resolution and the appearance of test phantom images. Phase contrast effects and spatial resolution were studied using a previously established method (using edge profiles) and by computing the system spatial frequency response at various geometries. It was demonstrated that the magnitude of the phase contrast enhancement effect reaches a stable maximum at a magnification of x 4. It has also been shown that a continual increase in both the spatial resolution together with an improved signal to noise ratio occurs up to the maximum permissible magnification geometry, with effects of focal spot blur being negligible. In practice, the limited size of the digital detector and the difficulty of object alignment can constrain the use of the very high magnification option.

Phantoms, Imaging↗