Publications and source records attributed to Jan Hálek.

2 recordsLinked to original sources

A contribution to sonograph image quality estimation using point spread function.

In medical sonography, sonograph image quality is an essential aspect for the safety of both patient and doctor. Its evaluation therefore requires an accurate and objective method for measurement. In this regard, a number of methods are in current use. Most of these are based on tissue mimicking phantom imaging. In contrast, we have used another principle based on Point Spread Function (PSF) analysis which is a product of the measuring system we have developed. In this case, the measured sonograph scans a small metallic ball target that moves in a water bath on a specified trajectory. The Region Of Interest (ROI) of the sonogram containing the ball target picture is digitised and the amplitude of the pixels analysed. The result is the PSF from which we calculate the lateral resolution (LR). For this purpose, we use our own original software. Using this method, we have to date been able to plot LR characteristics over the scanning plane. The method allows us to differentiate separate scanning lines and even multiple focal areas for dynamic focussing systems. It can detect malfunctions in dynamic focussing, size of aperture, time gain compensation function and/or transducer element failure. The procedure itself is not as easy or as fast to use as tissue mimicking phantoms or 3D signal to noise ratio evaluation, but it provides accurate and objective numeric parameters corresponding to the quality of image at any specified point over the whole scanning area. It is also a very powerful tool when used in combination with the other methods mentioned above.

Phantoms, Imaging↗

Surface artery volume pulse wave measurement - verification of a new method.

The aim of this paper is to prove the possible reproducibility of measurement with a new developed device for artery elasticity monitoring and determining the standard of major pulse wave parameters. As a measurement sensor, a conic probe with thin convex membrane was used. This technique allows setting an arbitrary pressure to a measured surface artery. We measured pulse waves on the radial arteries of 108 individuals. We expected similar features in arterial wall elasticity. We concentrated primarily on the amount of subcutaneous fat. For the measured waves we evaluated five following pulse wave parameters: relative crest time, elasticity index, dicrotic wave attenuation, dicrotic wave time and interwave distance. There were no significant differences in measured pulse wave parameters among the tested groups of subjects.

Blood Flow Velocity↗