Search PubMed⌕ Search

PubMed · 15796371

Artificial disc.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Kenneth Burkus, David W Polly, Matthew Gornet. 2005. Artificial disc.. https://doi.org/10.3171/spi.2005.2.3.0395

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Why fine-wire fixators work: an analysis of pressure distribution at the wire-bone interface.

Tensioned fine-wire external fixator systems have been used successfully for the treatment of fractures, mal-unions and for limb lengthening for many years. When used in metaphyseal bone, this type of fixator has a lower loosening rate than half-pin fixators. The differing mechanical properties of these fixator systems have been investigated extensively; however, most studies have centered on the mechanical properties of the fixator as a whole. Our knowledge of the interactions occurring at the interface between implant and bone remains sparse. In order to investigate this interaction, we devised a simple experimental model to characterise the distribution of pressure in cancellous bone surrounding a tensioned wire under loading conditions. Comparison was then made to a similar model of a half-pin fixator. Pressure was measured using pressure sensitive film at various distances away from the implant-bone interface. Static, single cycle loading of the model was performed with a Universal Testing Machine. Pressure distribution in the fine-wire model was found to occur in three regions: polar, beam loading and uniform. Polar patterns were seen closest to the wire with pressure concentrated at the entry and exit points of the wire. Beam loading was seen at a distance of 1.5 mm from the wire and pressure reached a uniform distribution at 4.0 mm. Most of the pressure measured was less than 2 MPa, which is less than the yield strength of cancellous bone (2-7 MPa). Higher loads produced higher stresses but the distribution pattern was similar. In contrast, the half-pin model showed far higher pressures (20 MPa), which were present deeper in the bone specimen. These results further our understanding of the biomechanics of fine-wire fixators and may explain the lower loosening rate of this type of fixator when compared to half-pin fixators used in metaphyseal bone.

Biomechanical Phenomena↗

Comparison and evaluation of two common methods to measure center of mass displacement in three dimensions during gait.

Center of mass displacement during gait has frequently been used as an indicator of gait efficiency or as a complement to standard gait analysis. With technological advances, measuring the center of mass as the centroid of a multi-segment system is practical and feasible, but must first be compared to the well-established Newtonian computation of double-integrating the ground reaction force. This study aims to verify that the kinematic centroid obtained from a commonly-used model (Vicon Peak Plug-In-Gait) provides at least as reliable measurements of center of mass displacement as those obtained from the ground reaction forces. Gait data was collected for able-bodied children and children with myelomeningocele who use larger lateral center of mass excursions during gait. Reasonable agreement between methods was found in fore-aft and vertical directions, where the methods' excursions differed by an average of less than 10 mm in either direction, and the average RMS differences between methods' computed curves were 6 and 13 mm. Particularly good agreement was observed in the lateral direction, where the calculated excursions differed by an average of less than 2 mm and the RMS difference was 5 mm. Error analyses in computing the center of mass displacement from ground reaction forces were performed. A 5% deviation in mass estimation increased the computed vertical excursion twofold, and a 5% deviation in the integration constant of initial velocity increased the computed fore-aft excursions by 10%. The suitability of calculating center of mass displacement using ground reaction forces in a patient population is questioned. The kinematic centroid is susceptible to errors in segment parameters and marker placement, but results in plausible results that are at least within the range of doubt of the better-established ground reaction force integration, and are more useful when interpreting 3-D gait data.

Biomechanical Phenomena↗

A simple 1+ dimensional model of rowing mimics observed forces and motions.

We have devised a simple, yet predictive model of the mechanics of both sculling and sweep rowing that reasonably mimics observed kinematic and force data. Our physical model is largely based upon the model proposed by Alexander [Alexander, F. H. (1925). The theory of rowing. In Proceedings of the University of Durham Philosophical Society (pp. 160-179).]. The model's primary features include: one dimensional momentum balance, a point mass rower, infinitely stiff oars with inertia and non-infinitesimal stroke angles, and quadratic relationships between force and velocity for the boat and oar blade. Using an inverse dynamics approach, we are able to construct reasonable fits to force and kinematic data of real rowing. We show that the model is able to reasonably well predict boat velocity even when we do not fit for it. A sensitivity analysis shows that the quality of fit is more sensitive to the boat and oar drag coefficients than to other physical parameters. Allowing oar slip (C(D) < infinity) proves to be a necessary model ingredient but, for example, allowing for oar flexibility does not improve the quality of fit. The model seems to have the key terms and a minimum of superfluous terms for investigations of rowing.

Biomechanical Phenomena↗