Search PubMed⌕ Search

PubMed · 15551077

Simultaneous multichannel mass-specific detection for high-performance liquid chromatography using an array detector sector-field mass spectrometer.

Abstract

The use of a separation step, such as liquid chromatography, prior to inductively coupled plasma mass spectrometry (ICP-MS) has become a common tool for highly selective and sensitive analyses. This type of coupling has several benefits including the ability to perform speciation analysis or to remove isobaric interferences. Several limitations of conventional instruments result from the necessity to scan or pulse the mass spectrometer to obtain a complete mass spectrum. When the instrument is operated in such a non-continuous manner, duty cycle is reduced, resulting in poorer absolute limits of detection. Additionally, with scanning instruments, spectral skew can be introduced into the measurement, limiting quantitation accuracy. To address these shortcomings, a high-performance liquid chromatograph has been coupled to an ICP-MS capable of continuous sample introduction and simultaneous multimass detection. These features have been realized with a novel detector array, the focal plane camera. Instrument performance has been tested for both speciation analysis and for the elimination of isobaric interferences. Absolute limits of detection in the sub picogram to tens of picograms regime are obtainable, while the added mass dimension introduced by simultaneous detection dramatically increases chromatographic peak capacity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

James H Barnes, Gregory D Schilling, Steven F Stone, Roger P Sperline, M Bonner Denton, Erick T Young, Charles J Barinaga, David W Koppenaal, Gary M Hieftje. 2004-07-28. Simultaneous multichannel mass-specific detection for high-performance liquid chromatography using an array detector sector-field mass spectrometer.. https://doi.org/10.1007/s00216-004-2686-y

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Room-temperature broadband emission of an InGaAs/GaAs quantum dots laser.

We report the first demonstration to our knowledge of an ultrabroad emission laser using InGaAs/GaAs quantum dots by cycled monolayer deposition. The device exhibits a lasing wavelength coverage of approximately 40 nm at an approximately 1160 nm center wavelength at room temperature. The broadband signature results from the superposition of quantized lasing states from highly inhomogeneous dots.

Arsenicals↗

High electron mobility InAs nanowire field-effect transistors.

Single-crystal InAs nanowires (NWs) are synthesized using metal-organic chemical vapor deposition (MOCVD) and fabricated into NW field-effect transistors (NWFETs) on a SiO(2)/n(+)-Si substrate with a global n(+)-Si back-gate and sputtered SiO(x)/Au underlap top-gate. For top-gate NWFETs, we have developed a model that allows accurate estimation of characteristic NW parameters, including carrier field-effect mobility and carrier concentration by taking into account series and leakage resistances, interface state capacitance, and top-gate geometry. Both the back-gate and the top-gate NWFETs exhibit room-temperature field-effect mobility as high as 6580 cm(2) V(-1) s(-1), which is the lower-bound value without interface-capacitance correction, and is the highest mobility reported to date in any semiconductor NW.

Arsenicals↗