Search PubMed⌕ Search

Biomedical subjects

M Bonner Denton

Publications and source records attributed to M Bonner Denton.

11 recordsLinked to original sources

Characterization of a second-generation focal-plane camera coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph.

A second-generation Faraday-strip array detector has been coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph, thereby offering simultaneous acquisition of a range of mass-to-charge ratios. The second-generation device incorporates narrower, more closely spaced collectors than the earlier system. Furthermore, the new camera can acquire signal on all collectors at a frequency greater than 2 kHz and has the ability to independently adjust the gain level of each collector. Each collector can also be reset independently. With these improvements, limits of detection in the hundreds of picograms per liter for metals in solution have been obtained. Some additional features, such as a broader linear dynamic range (over 7 orders of magnitude), greater resolving power (up to 600), and improved isotope ratio accuracy were attained. In addition, isotope ratio precision as low as 0.018% RSD was achieved.

Journal Article↗

MS detectors.

Explore the source record for details and available documents.

Journal Article↗

Advances in array detectors for X-ray diffraction techniques.

Improved focal plane array detector systems are described which can provide improved readout speeds, random addressing and even be employed to simultaneously measure position, intensity and energy. This latter capability promises to rekindle interests in Laue techniques. Simulations of three varieties of foil mask spectrometer in both on- and off-axis configurations indicate that systems of stacked silicon detectors can provide energy measurements within 1% of the true value based on the use of single 'foils' and approximately 10000 photons. An eight-detector hybrid design can provide energy coverage from 4 to 60 keV. Energy resolution can be improved by increased integration time or higher flux experiments. An off-axis spectrometer design in which the angle between the incident beam and the detector system is 45 degrees results in a shift in the optimum energy response of the spectrometer system. In the case of a 200 microm-thick silicon absorber, the energy optimum shifts from 8.7 keV to 10.3 keV as the angle of incidence goes from 0 to 45 degrees. These new designs make better use of incident photons, lower the impact of source flicker through simultaneous rather than sequential collection of intensities, and improve the energy range relative to previously reported systems.

Computer Simulation↗

Evaluation of a hydrogen laser vacuum ultraviolet source for photoionization mass spectrometry of pharmaceuticals.

A photoionization hydrogen laser time-of-flight mass spectrometer system (H2-TOFMS) has been evaluated for the rapid analysis of drugs of abuse and pharmaceutical agents extracted from prescription tablets and spiked urine samples. The spectra obtained using the H2-TOFMS showed primarily intact molecular ions (M+*) after introduction by a heated probe and irradiation with vacuum ultraviolet (VUV) photons from the laser. Samples analyzed by this technique required only a simple solid-phase extraction step; no chromatographic separation or derivatization was necessary to identify the drugs of abuse or pharmaceutical agents.

Acetaminophen↗

Simultaneous multichannel mass-specific detection for high-performance liquid chromatography using an array detector sector-field mass spectrometer.

The use of a separation step, such as liquid chromatography, prior to inductively coupled plasma mass spectrometry (ICP-MS) has become a common tool for highly selective and sensitive analyses. This type of coupling has several benefits including the ability to perform speciation analysis or to remove isobaric interferences. Several limitations of conventional instruments result from the necessity to scan or pulse the mass spectrometer to obtain a complete mass spectrum. When the instrument is operated in such a non-continuous manner, duty cycle is reduced, resulting in poorer absolute limits of detection. Additionally, with scanning instruments, spectral skew can be introduced into the measurement, limiting quantitation accuracy. To address these shortcomings, a high-performance liquid chromatograph has been coupled to an ICP-MS capable of continuous sample introduction and simultaneous multimass detection. These features have been realized with a novel detector array, the focal plane camera. Instrument performance has been tested for both speciation analysis and for the elimination of isobaric interferences. Absolute limits of detection in the sub picogram to tens of picograms regime are obtainable, while the added mass dimension introduced by simultaneous detection dramatically increases chromatographic peak capacity.

Arsenicals↗

Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 2. Use with an inductively coupled plasma.

A novel charge-sensitive detector array, termed the focal plane camera (FPC), has been coupled to a Mattauch-Herzog mass spectrograph (MHMS) with an inductively coupled plasma ionization source. The FPC employs an array of gold Faraday cups, each with its own charge-integrating circuit that allows the simultaneous detection of several m/z ratios. The ion-sampling interface of the MHMS has been redesigned to provide better heat transfer away from the sampler and skimmer cones and to reduce the negative effects of turbulent gas flows around the plasma. The instrument has produced limits of detection in the tens to hundreds of parts per quadrillion regime and isotope ratio accuracy and precision of 5% error and 0.007% RSD, respectively. Limits of detection with the FPC are comparable to those obtained with a single-channel secondary electron multiplier (SEM). However, the isotope ratio accuracy and precision are better with the FPC than when the SEM is employed. The dynamic range has been shown to be linear over 7 orders of magnitude.

Journal Article↗

Use of a novel array detector for the direct analysis of solid samples by laser ablation inductively coupled plasma sector-field mass spectrometry.

The use of laser ablation (LA) as a sample-introduction method for inductively coupled plasma mass spectrometry (ICP-MS) creates a powerful tool for trace elemental analysis. With this type of instrument, high analyte spatial resolution is possible in three dimensions with ng/g limits of detection and minimal sample consumption. Here, simultaneous detection is used to eliminate the correlated noise that plagues the ablation process. This benefit allows analyses to be performed with single laser pulses, resulting in improved depth resolution, even less sample consumption, and improved measurement precision. The new instrument includes an LA sample-introduction system coupled to an ICP ionization source and a Mattauch-Herzog mass spectrograph (MHMS) fitted with a novel array detector. With this instrument, absolute limits of detection are in the tens to hundreds of fg regime and isotope-ratio precision is better than 0.02% RSD with a one-hour integration period. Finally, depth-profile analysis has been performed with a depth resolution of 5 nm per ablation event.

Journal Article↗

Mercury binding to the chelation therapy agents DMSA and DMPS and the rational design of custom chelators for mercury.

Clinical chelation therapy of mercury poisoning generally uses one or both of two drugs--meso-dimercaptosuccinic acid (DMSA) and dimercaptopropanesulfonic acid (DMPS), commercially sold as Chemet and Dimaval, respectively. We have used a combination of mercury L(III)-edge X-ray absorption spectroscopy and density functional theory calculations to investigate the chemistry of interaction of mercuric ions with each of these chelation therapy drugs. We show that neither DMSA nor DMPS forms a true chelate complex with mercuric ions and that these drugs should be considered suboptimal for their clinical task of binding mercuric ions. We discuss the design criteria for a mercuric specific chelator molecule or "custom chelator", which might form the basis for an improved clinical treatment.

Chelating Agents↗

Characterization of the explosive triacetone triperoxide and detection by ion mobility spectrometry.

The improvised explosive triacetone triperoxide (TATP) was synthesized and characterized by 1H-nuclear magnetic resonance (NMR), 13C-NMR, Raman and infrared (IR) spectroscopy. Triacetone triperoxide was subsequently analyzed by ion mobility spectrometry (IMS) in positive ion mode, and detected as a cluster of three peaks with a drift time of the most intense peak at 13.06 ms. Triacetone triperoxide was then analyzed after dissolution in toluene, where a dramatic increase in peak intensity was observed, at a flight time of 12.56 ms (K0=2.71 cm2V(-1)s(-1)). Triacetone triperoxide was subsequently analyzed by coupling the ion mobility spectrometer to a triple quadrupole mass spectrometer, where a single peak at m/z of 223 atomic mass units identified the species present in the ion mobility spectra as being triacetone triperoxide.

Acetone↗

Synthesis, purification, and structural characterization of the dimethyldiselenoarsinate anion.

A novel arsenic-selenium solution species was synthesized by reacting equimolar sodium selenite and sodium dimethylarsinate with 10 mol equiv of glutathione (pH 7.5) in aqueous solution. The solution species showed a single (77)Se NMR resonance at 112.8 ppm. Size-exclusion chromatography (SEC) using an inductively coupled plasma atomic emission spectrometer (ICP-AES) as the simultaneous arsenic-, selenium-, sulfur-, and carbon-specific detector revealed an arsenic-selenium moiety with an As:Se molar ratio of 1:2. Electrospray ionization mass spectrometry (ESI-MS) of the chromatographically purified compound showed a molecular mass peak at m/z 263 in the negative ion mode. Fragmentation of the parent ion (ESI-MS-MS) produced (CH(3))(2)As(-) and Se(2)(-) fragments. Arsenic and selenium extended X-ray absorption fine structure spectroscopy (EXAFS) of the purified species revealed two As-C interactions at 1.943 A and two As-Se interactions at 2.279 A. On the basis of these results this novel solution species is identified as the dimethyldiselenoarsinate anion.

Chromatography, Gel↗

Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source.

A Mattauch-Herzog geometry mass spectrograph (MHMS) has been equipped with a novel array detector, the focal plane camera (FPC). The FPC consists of an array of gold Faraday cups, each coupled to its own integrator, with interrogation of the integrators performed by a multiplexer. The initial coupling of this instrument with a pin-type glow discharge source has provided limits of detection in the single to hundreds of nanograms per gram regime; isotope ratio accuracy and precision better than 5% error and 0.2% RSD, respectively; and a linear dynamic range of at least 6 orders of magnitude. A current weakness of the FPC is its pixel size, which limits both sensitivity and baseline resolution (to R = 130). The minimum data acquisition time for multiple images at present is 1 ms/image, with a dead time of 3.2 ms between images, which will limit the ability of the FPC to monitor extremely short transient signals.

Journal Article↗