Material considerations for intervertebral disc replacement implants.

Abstract

Cervical and lumbar disc replacements are being performed with increasing frequency. Much of the background for the development for these implants is drawn from the literature of other joint replacements that have been in evolution and use for decades. Important variables for the function and longevity of such disc arthroplasty implants are clearly defined by the material properties of the components used for their production. The most frequently considered materials are cobalt-chrome alloys, titanium alloys, stainless steels, polyethylene, polyurethane and ceramics. In addition to implant materials, the interfaces of such materials must be considered. The bearing surfaces of an implant, in particular, are at risk of wear and failure. Overall, successful, long-term total disc arthroplasty requires a thorough understanding of biomaterials and how they can be used to achieve their desired goals.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sudeep Taksali, Jonathan N Grauer, Alexander R Vaccaro. Material considerations for intervertebral disc replacement implants.. https://doi.org/10.1016/j.spinee.2004.07.012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Adjacent level intradiscal pressure and segmental kinematics following a cervical total disc arthroplasty: an in vitro human cadaveric model.

STUDY DESIGN: In vitro investigation of cervical adjacent level intradiscal pressures (IDPs) following a total disc replacement arthroplasty. OBJECTIVES: The current in vitro study was undertaken to compare adjacent level IDPs and operative level kinematics following a cervical arthroplasty versus an arthrodesis procedure. SUMMARY OF BACKGROUND DATA: Clinical data indicate the incidence of symptomatic transition syndrome to be as high as 3% annually following a cervical interbody arthrodesis. Recent developments in the motion preservation technology should, in theory, minimize transition syndrome at the adjacent levels. METHODS: A total of 10 human cadaveric cervical spines were used in this investigation. Following intact analysis, all specimens were sequentially reconstructed at C5-C6 with 1) total disc replacement (TDR), 2) allograft dowel, and 3) allograft dowel + anterior cervical plate. Testing was performed in displacement control under axial rotation, flexion/extension, and lateral bending loading modes. IDPs were recorded at C4-C5 and C6-C7 whereas peak range of motion (ROM) and NZ were monitored at C5-C6 level. RESULTS: Similar IDPs were recorded between the intact condition and a TDR reconstruction at both adjacent levels under all loading modes (P > 0.05). However, the C4-C5 IDP values produced under flexion/extension testing for both arthrodesis treatments were significantly higher than the means obtained for the intact and disc replacement groups (P < 0.05). Similar intergroup differences were observed at the C6-C7 level; however, statistical significance was achieved during all three loading methods (P < 0.05). C5-C6 ROM analysis indicated a significantly lower ROM for both arthrodesis constructs compared with intact and TDR groups during flexion/extension testing (P < 0.05). No differences were recorded between the intact and the total disc replacement group under any loading conditions (P > 0.05). CONCLUSION: This is a first study to document that a cervical disc replacement arthroplasty procedure maintains adjacent level IDPs and reconstruction level kinematics near the preoperative values. Consequently, total disc replacement may provide an alternative to conventional surgical management of cervical discogenic pathology decreasing the incidence of symptomatic transition syndrome.

Arthroplasty, Replacement↗

Chemical nature of implant-derived titanium(IV) ions in synovial fluid.

Previous investigations have indicated a deleterious leakage of Ti(III) and/or Ti(IV) species from Ti-Al-V alloy joint prostheses into adjacent tissue, synovium or synovial fluid (SF) in vivo. In view of the importance of the particular chemical nature of such complexes in determining their biological activity, we have employed high field proton (1H) NMR spectroscopy to "speciate" Ti(IV) in inflammatory SF. Treatment of osteoarthritic SF samples with increasing concentrations of Ti(IV) (0.10-1.03 mM [TiO(C2O4)2]2-) gave rise to a specific broadening of the citrate proton resonances, indicating that this bioavailable oxygen-donor ligand plays an important role in complexing implant-derived Ti(IV). 1H NMR analysis of Ti(IV)-loaded SF samples subsequently treated with a large excess of ascorbate (0.05 M) showed that this added Ti(IV) chelator was only poorly effective in removing this metal ion from Ti(IV)-citrate/Ti(IV)-oxycitrate complexes. The results obtained here provide evidence for complexation of the low-molecular-mass (non-protein-bound) fraction of implant-derived Ti(IV) by citrate in vivo.

Arthroplasty, Replacement↗

Effect of total disc replacement with ProDisc on intersegmental rotation of the lumbar spine.

STUDY DESIGN: The mechanical behavior of the lumbar spine after insertion of a ProDisc prosthesis was studied using 3-dimensional nonlinear finite element models. OBJECTIVE: To determine how the mechanical behavior of the lumbar spine is affected by the implant position and height, as well as by removing different portions of the natural disc and resuturing the anterior longitudinal ligament (ALL). SUMMARY OF BACKGROUND DATA: Little is known about how the affected and adjacent levels of the spine are influenced by the implant height and position or by the surgical procedure. METHODS: The artificial disc ProDisc was integrated in a validated 3-dimensional, nonlinear, finite element model of the lumbar spine. The model was loaded with the upper body weight and muscle forces to simulate standing, 30 degrees flexion, 15 degrees extension, and 6 degrees axial rotation. The disc position was varied by up to 2 mm in both an anterior and posterior direction. Three different disc heights were investigated, as well as the influence of removing different portions of the natural disc and resuturing the ALL. RESULTS: Implant position strongly influences intersegmental rotation for the loading cases of standing and flexion. A disc height 2 mm in excess of the normal disc space increases intersegmental rotation at implant level during standing and extension. The values for intersegmental rotation are closer to those for the intact spine when lateral portions of the anulus are not removed. Resuturing the ALL has a strong effect on the loading cases of extension and standing. CONCLUSIONS: When implanting an artificial disc, great care should be taken in choosing the optimal height and correct position for the implant. Lateral portions of the anulus should be preserved whenever possible. A perfect reconstruction of the ALL would help to restore the biomechanics to normal.

Arthroplasty, Replacement↗