Search PubMed⌕ Search

PubMed · 15511479

Invited commentary.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shafie Fazel, Denis Angoulvant, Richard D Weisel. 2004. Invited commentary.. https://doi.org/10.1016/j.athoracsur.2003.10.065

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Vacuum-assisted apical suction devices induce passive electrical changes consistent with myocardial ischemia during off-pump coronary artery bypass graft surgery.

OBJECTIVE: Off-pump coronary artery bypass graft surgery is common therapy to completely revascularize diseased hearts. In order to graft posterior arteries in this procedure, the heart must be lifted from the chest cavity and manipulated to expose the surgical field using an apical suction device. This suction device may cause unwanted myocardial ischemia. METHODS: In this observational study, we measured myocardial electrical impedance, a parameter that responds to myocardial ischemia, as well as ST-segment changes during off-pump coronary artery bypass graft surgery in 12 patients with two-vessel coronary artery disease undergoing revascularisation of the left anterior descending and the posterior descending coronary arteries. During the posterior descending artery revascularisation phase of the procedure the apical suction device was oriented over the electrodes used to measure myocardial electrical impedance, thus allowing us the opportunity to assess myocardial ischemia in this region of the heart. RESULTS: In these 12 patients, myocardial electrical impedance progressively increased under the suction device during posterior coronary artery revascularisation, suggesting that myocardial ischemia developed in this region of the myocardium. ST-segment changes were negligible while the heart was vertically displaced (and the suction device attached), but increased immediately when the heart was returned to the neutral anatomical position. CONCLUSION: Our data suggest that the apical suction device may cause ischemia while the heart is vertically displaced and electrically disconnected from the body. Under these conditions, ST-segment changes may not detect myocardial ischemia. Myocardial electrical impedance has the potential to reliably detect intraoperative myocardial ischemia under these circumstances.

Coronary Artery Bypass, Off-Pump↗

Off-pump coronary artery bypass grafting in a patient with Child class C liver cirrhosis awaiting liver transplantation.

We report the case of a Child class C cirrhotic patient who was diagnosed with coronary artery disease in the course of his pretransplantation evaluation. He underwent off-pump coronary artery bypass grafting (OPCAB), which was complicated with acute renal failure. The morbidity and mortality associated with cardiac operation in patients with cirrhosis is discussed, and the potential advantage of OPCAB in this patient population is emphasized.

Coronary Artery Bypass, Off-Pump↗

Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy.

BACKGROUND: In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible ischemic events in off-pump coronary artery bypass procedures. METHODS: In 15 elective patients undergoing off-pump myocardial revascularization, intravascular near-infrared spectroscopic analysis of coronary venous blood was performed. NIR signals were transferred through a fiberoptic catheter for signal emission and collection. For data analysis and processing, a miniature spectrophotometer with multivariate statistical package was used. Signal acquisition and analysis were performed before and after revascularization. Spectroscopic data were compared with hemodynamic parameters, electrocardiogram, transesophageal echocardiography and laboratory findings. RESULTS: A conversion to extracorporeal circulation was not necessary. The mean number of grafts per patient was 3.1 +/- 0.6. An intraoperative myocardial ischemia was not evident, as indicated by electrocardiogram and transesophageal echocardiography. Continuous spectroscopic analysis showed reproducible absorption spectra of coronary sinus blood. Due to uneventful intraoperative courses, clear ischemia-related changes could be detected in none of the patients. CONCLUSION: Our initial results show that intravascular near-infrared spectroscopy can reliably be used for an online intraoperative ischemia monitoring in off-pump coronary artery bypass surgery. However, the method has to be further evaluated and standardized to determine the role of spectroscopy in off-pump coronary artery bypass surgery.

Coronary Artery Bypass, Off-Pump↗