CT urography.

Abstract

With the recent introduction of multi-detector row helical computed tomography (CT), the radiologic evaluation of patients with urologic disease has changed rapidly. Two major approaches to CT urography have been developed. The first approach combines axial CT with timed excretory urography (EU) performed by using conventional radiography, digital radiography, or CT scanned projection radiography (SPR). This approach produces traditional projection urograms, and the timed imaging technique is familiar to radiologists and clinicians. Additional excretory phase CT can be performed when the EU findings are positive or indeterminate. Improved CT SPR processing technology produces radiographlike images, thus eliminating patient transportation between the CT and urography suites or the necessity for a CT suite with a ceiling-mounted x-ray tube and a modified CT tabletop for performance of EU. The second approach to CT urography combines axial CT with thin-section excretory phase CT. The near-isotropic volume data set enables creation of high-resolution two- and three-dimensional reformatted images. However, the increased amount of radiation and the time required for data manipulation are concerns. Further studies evaluating large numbers of patients with various urothelial abnormalities will be necessary to determine the optimal CT urography technique for clinical practice.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Akira Kawashima, Terri J Vrtiska, Andrew J LeRoy, Robert P Hartman, Cynthia H McCollough, Bernard F King. 2004. CT urography.. https://doi.org/10.1148/rg.24si045513

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Combined confocal/en face T-scan-based ultrahigh-resolution optical coherence tomography in vivo retinal imaging.

Combined confocal scanning ophthalmoscopy/en face T-scan-based ultrahigh-resolution optical coherence tomography (OCT) of the human retina in vivo is reported for the first time to our knowledge. The system uses a superluminescent diode-based broadband source, which gives an axial resolution of 3.2 microm in the retina. We demonstrate acquisition of T-scan-based OCT B-scan and simultaneous confocal/C-scan images of the human retina of large lateral size (covering a field of up to 20 degrees ) at a frame rate of 2Hz.

Equipment Design↗

Spectrally encoded slit confocal microscopy.

A simple and cost-effective method for real-time imaging in confocal microscopy is proposed. Spectrally encoded slit confocal microscopy (SESCoM) uses a spectral encoding technique together with a confocal slit aperture to achieve two-dimensional images. Simulation and experimental results of the SESCoM's axial and lateral performances are presented. The measured FWHM of the axial response is 1.15 mum when an objective with a NA of 0.95 is used. FWHMs of the lateral line spread functions are measured to be 236 and 244 nm along the x and y directions, respectively. Both the axial and the lateral experimental results agree well with the simulation results.

Equipment Design↗

Evanescent Bessel beam generation via surface plasmon resonance excitation by a radially polarized beam.

A simple setup for generating evanescent Bessel beams is proposed. When a radially polarized beam is strongly focused onto a dielectric-metal interface, the entire beam is p-polarized with respect to the dielectric-metal interface, enabling excitation of surface plasmons from all directions. The angular selectivity of surface plasmon excitation mimics the function of an axicon, leading to an evanescent nondiffracting Bessel beam. The created evanescent Bessel beam may be used as a virtual probe for near-field optical imaging and sensing applications.

Equipment Design↗