Search PubMed⌕ Search

PubMed · 15350414

Observations on solid phase micro-extraction for MTBE analysis.

Abstract

In a recent study of aqueous phase methyl tertiary butyl ether (MTBE) adsorption onto hydrophobic molecular sieves, the solid phase micro-extraction gas chromatography analytical technique was used to measure MTBE concentrations in water. The method was especially beneficial in measuring MTBE concentrations in the microg/l range, but anomalies were observed that investigators should be aware of before employing this technique. Specifically, it was observed that the calibration of the extraction fiber with known MTBE concentrations was non-linear over all concentration ranges. The technique was not suited to higher concentrations, and dilutions were necessary to increase the working range of the technique. Lastly, the fiber was observed to extract increasingly less MTBE from known standard solutions over time, requiring repeated calibrations to obtain reliable concentrations of unknown samples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ayşe Erdem-Senatalar, John A Bergendahl, Robert W Thompson. 2004. Observations on solid phase micro-extraction for MTBE analysis.. https://doi.org/10.1016/j.chemosphere.2004.06.031

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Chemical images: technical approaches and issues.

Chemical mapping techniques using Raman microscopy are introduced, and using an example of a pharmaceutical tablet, the practical aspects of data collection and processing to produce a chemical image of the sample are detailed. Issues related to data processing, instrument standards, chemical image reportable errors, and the interpretation of chemical images are presented to encourage debate, develop solutions, and promote use in other challenging scientific applications. applications.

Calibration↗

Determination of chlorine dioxide in water by gas chromatography-mass spectrometry.

A sensitive gas chromatographic method has been established for the determination of chlorine dioxide in water. With weak basic conditions (pH 9.0), chlorine dioxide reacts with iodide to form iodine, which reacts with 2,6-dialkylphenol to form 4-iodo-2,6-dialkylphenol. The volatile organic derivative was extracted with ethyl acetate, and then measured by gas chromatography-mass spectrometry (GC-MS). The reaction of the active proton of 2,6-dialkylphenols (2,6-dimethylphenol, 2,6-di-isopropylphenol and 2,6-di-tert-butylphenol) with iodine was tested, and compared to each other in terms of reactivity and stability of the derivatives. 2,6-dimethylphenol showed rapid reaction with iodine, and its derivative was stable for 2 weeks. The detection limit of chlorine dioxide in water was about 1.0 ng/mL, and the calibration curve showed good linearity with r2 = 0.998. The existent concentration of chlorine dioxide in water was calculated from multiplying the concentration calculated from the calibration curve of 4-iodo-2,6-dimethylphenol by 0.544. The method was sensitive, reproducible and simple enough to permit the reliable analysis of chlorine dioxide at the low ng/mL level in water.

Calibration↗

New cold-fiber headspace solid-phase microextraction device for quantitative extraction of polycyclic aromatic hydrocarbons in sediment.

A new automated headspace solid-phase microextraction (HS-SPME) sampling device was developed, with the capability of heating the sample matrix and simultaneously cooling the fiber coating. The device was evaluated for the quantitative extraction of polycyclic aromatic hydrocarbons (PAHs) from solid matrices. The proposed device improves the efficiency of the release of analytes from the matrix, facilitates the mass transfer into the headspace and significantly increases the partition coefficients of the analytes, by creating a temperature gap between the cold-fiber (CF) coating and the hot headspace. The reliability and applicability of previously reported cold-fiber devices are significantly enhanced by this improvement. In addition, it can be easily adopted for full automation of extraction, enrichment and introduction of different samples using commercially available autosampling devices. Sand samples spiked with PAHs were used as solid matrices and the effect of different experimental parameters were studied, including the extraction temperature, extraction time, moisture content, and the effect of sonication and modifier under optimal experimental conditions, linear calibration curves were obtained in the range of 0.0009-1000 ng/g, with regression coefficients higher than 0.99 and detection limits that ranged from 0.3 to 3 pg/g. Reproducible, precise and high throughput extraction, monitoring and quantification of PAHs were achieved with the automated cold-fiber headspace solid-phase microextraction (CF-HS-SPME) device coupled to GC-flame ionization detection. Determination of PAHs in certified reference sediments using the proposed approach exhibited acceptable agreement with the standard values.

Calibration↗