Search PubMed⌕ Search

PubMed · 15345574

Simultaneous topography and recognition imaging using force microscopy.

Abstract

We present a method for simultaneously recording topography images and localizing specific binding sites with nm positional accuracy by combining dynamic force microscopy with single molecule recognition force spectroscopy. For this we used lysozyme adsorbed to mica, the functionality of which was characterized by enzyme immunoassays. The topography and recognition images were acquired using tips that were magnetically oscillated during scanning and contained antibodies directed against lysozyme. For cantilevers with low Q-factor (approximately 1 in liquid) driven at frequencies below resonance, the surface contact only affected the downward deflections (minima) of the oscillations, whereas binding of the antibody on the tip to lysozyme on the surface only affected the upwards deflections (maxima) of the oscillations. The recognition signals were therefore well separated from the topographic signals, both in space (Delta z approximately 5 nm) and time (approximately 0.1 ms). Topography and recognition images were simultaneously recorded using a specially designed electronic circuit with which the maxima (U(up)) and the minima (U(down)) of each sinusoidal cantilever deflection period were depicted. U(down) was used for driving the feedback loop to record the height (topography) image, and U(up) provided the data for the recognition image.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cordula M Stroh, Andreas Ebner, Manfred Geretschläger, Günter Freudenthaler, Ferry Kienberger, A S M Kamruzzahan, Sandra J Smith-Gill, Hermann J Gruber, Peter Hinterdorfer. 2004. Simultaneous topography and recognition imaging using force microscopy.. https://doi.org/10.1529/biophysj.104.043331

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Organoclay formulations of acetochlor: effect of high salt concentration.

This study aimed to evaluate new methodology for designing ecologically acceptable formulations of acetochlor. Modification of montmorillonite with phenyltrimethylammonium chloride (PTMA) or benzyltrimethylammonium chloride (BTMA) and organoclay formulations of acetochlor were prepared in the presence of high concentrations of sodium chloride (150 g/L). Acetochlor concentration in the equilibrium solutions was determined by HPLC. Release of acetochlor in a water system was performed by a funnel experiment. Leaching of acetochlor in soil was determined by a bioassay using a column technique and Setaria viridis as a test plant. The adsorbed amounts of acetochlor on montmorillonite exchanged by PTMA or BTMA were increased as NaCl concentration increased in the equilibrium solution. Leaching of acetochlor from organoclay formulations was significantly inhibited to the top soil layer (0-5 cm) when the formulations were prepared at extreme NaCl concentration (100-150 g/L). These results are in accord with a funnel experiment that showed a reduction in acetochlor release from the montmorillonite-based formulations. The application of this method for herbicide formulation would produce ecologically acceptable herbicide formulations that can significantly minimize the risk to groundwater pollution.

Aluminum Silicates↗

Quantification of the kinetics and thermodynamics of protein adsorption using atomic force microscopy.

Both in situ and ex situ methods for quantifying area fraction coverage of protein on a surface using atomic force microscopy were developed. The in situ method used a continuous fluid flow system to observe the kinetics of adsorption in real time. The ex situ method required immersing the sample in solution, drying the sample, and imaging in an ambient environment to obtain kinetic and isothermal data. These methods were developed using the plasma protein fibrinogen in a phosphate-buffered saline solution on grade IV muscovite mica and highly ordered pyrolytic graphite (HOPG) substrates. Kinetic and quasiisothermal data were obtained and a Langmuir model was fit to the data. An adsorption rate constant of 2.2 x 10(-4) mL . microg(-1)s(-1) and a desorption rate constant of 8.3 x 10(-5) s(-1) were found on an HOPG surface. Completely irreversible adsorption was found on the mica surface with an adsorption rate constant of 2.7 x 10(-4) mL . microg(-1)s(-1). Additionally, protein conformation and assembly orientation on these surfaces were documented where fibrinogen on HOPG formed a network-like structure, whereas fibrinogen on mica was more random. Also, nano-topographical factors (ledges) were seen as sites of preferential adsorption.

Aluminum Silicates↗

Following the formation of supported lipid bilayers on mica: a study combining AFM, QCM-D, and ellipsometry.

Supported lipid bilayers (SLBs) are popular models of cell membranes with potential biotechnological applications and an understanding of the mechanisms of SLB formation is now emerging. Here we characterize, by combining atomic force microscopy, quartz crystal microbalance with dissipation monitoring, and ellipsometry, the formation of SLBs on mica from sonicated unilamellar vesicles using mixtures of zwitterionic, negatively and positively charged lipids. The results are compared with those we reported previously on silica. As on silica, electrostatic interactions were found to determine the pathway of lipid deposition. However, fundamental differences in the stability of surface-bound vesicles and the mobility of SLB patches were observed, and point out the determining role of the solid support in the SLB-formation process. The presence of calcium was found to have a much more pronounced influence on the lipid deposition process on mica than on silica. Our results indicate a specific calcium-mediated interaction between dioleoylphosphatidylserine molecules and mica. In addition, we show that the use of PLL-g-PEG modified tips considerably improves the AFM imaging of surface-bound vesicles and bilayer patches and evaluate the effects of the AFM tip on the apparent size and shape of these soft structures.

Aluminum Silicates↗