Search PubMed⌕ Search

PubMed · 15264476

Exploding glass eyes.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L A Geddes. Exploding glass eyes.. https://doi.org/10.1109/memb.2004.1310987

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Factors influencing rehabilitation of sensorineural hearing loss with hearing aids].

BACKGROUND: A large proportion of older as well as younger patients do not use their hearing aids. Of the younger hearing impaired population, this occurs in the majority of those who do not benefit sufficiently from their hearing aids and, consequently, they face difficulties in their working and social life. SCIENTIFIC QUESTION: Our aim was to evaluate whether a classical hearing aid adjustment is of sufficient predictive value to determine whether adequate rehabilitation in everyday and professional life will occur. METHODS AND RESULTS: A questionnaire was returned by 197 adult hearing impaired patients. Only 108 were using their hearing aids all the time; 57 rarely and 32 never. The main reason for this low rehabilitation rate proved to be inadequate amplification. At the workplace, insufficient speech discrimination came into play. Another important factor was dysacusis induced by specific noise signals. There was an intolerable acoustic feedback in 40% which could not be sufficiently alleviated. Taking these results into account, only about a third of patients were sufficiently rehabilitated. CONCLUSIONS: Proof of effectiveness in a typical audiological testing situation is an important but not a fully reliable predictor for effectiveness in everyday life. Even when hearing aids are shown to be effective with such testing, their application in particular everyday or work situations may be insufficient of even impossible.

Equipment Failure Analysis↗

Performance of a cryogenic silicon monochromator under extreme heat load.

The performance of an indirectly cooled cryogenic silicon monochromator under heat loads up to 870 W has been studied. The investigation was performed over numerous parameters and included measurements of total flux, spectral density, rocking curves, angular beam profiles and crystal slope errors. An almost ideal monochromator performance was observed in the 270-570 W range of the heating power. At a heat load of approximately 400 W and under standard operation conditions, the crystal distortions did not exceed 1 micro rad. At the highest available heat load of 870 W, the crystal distortions were about 7 micro rad.

Equipment Failure Analysis↗

Performance evaluation of the new whole-body PET/CT scanner: Discovery ST.

Characterisation of the physical performance of the new integrated PET/CT system Discovery ST (GE Medical Systems) has been performed following the NEMA NU 2-1994 (N-94) and the NEMA NU 2-2001 (N-01) standards in both 2D and 3D acquisition configuration. The Discovery ST combines a four or eight multi-slice helical CT scanner with a PET tomograph which consists of 10,080 BGO crystals arranged in 24 rings. The crystal dimensions are 6.3 x 6.3 x 30 mm(3) and they are organised in blocks of 6 x 6 crystals, coupled to a single photomultiplier tube with four anodes. The 24 rings of the PET system allow 47 images to be obtained, spaced by 3.27 mm, and covering an axial field of view of 157 mm. The low- and high-energy thresholds are set to 375 and 650 keV, respectively. The coincidence time window is set to 11.7 ns. Using the NEMA N-94 standard, the main results were: (1) the average (radial and tangential) transverse spatial resolution (FWHM) at 1, 10 and 20 cm off axis was 6.28 mm, 7.09 mm and 7.45 mm in 2D, and 6.68 mm, 7.72 mm and 8.13 mm in 3D; (2) the sensitivity for true events was 8,567 cps/kBq/cc in 2D and 36,649 cps/kBq/cc in 3D; (3) the scatter fraction was 15% in 2D and 30% in 3D; (4) the peak true events rate, the true events rate at 50% of the system dead-time and the true events rate when equal to the random events rate were 750 kcps at 189.81 kBq/cc, 744 kcps at 186.48 kBq/cc and 686 kcps at 150.59 kBq/cc, respectively, in 2D, and 922 kcps at 44.03 kBq/cc, 834 kcps at 53.28 kBq/cc and 921 kcps at 44.03 kBq/cc in 3D; (5) the noise equivalent count (NEC) peak rate was 270 kcps at 34.38 kBq/cc in 3D, with random coincidences estimated by delayed events. Using the NEMA N-01 standards the main results were: (1) the average transverse and axial spatial resolution (FWHM) at 1 cm and 10 cm off axis was 6.28 (4.56) mm and 6.88 (6.11) mm in 2D, and 6.29 (5.68) mm and 6.82 (6.05) mm in 3D; (2) the average sensitivity for the two radial positions (r=0 cm and r=10 cm) was 1.93 cps/kBq in 2D and 9.12 cps/kBq in 3D; (3) the scatter fraction was 19% in 2D and 45% in 3D; (4) the NEC peak rate was 54 kcps at 46.99 kBq/cc in 2D and 45.5 kcps at 10.84 kBq/cc in 3D, when random coincidences were estimated by using k=2 in the NEC formula, while the NEC peak rate was 81 kcps at 64.43 kBq/cc and 66 kcps at 14.86 kBq/cc in 2D and 3D, respectively, when random coincidences were estimated by using k=1 in the NEC formula. The new integrated PET-CT system Discovery ST has good overall performances in both 2D and 3D, with in particular a high sensitivity and a very good 3D NEC response.

Equipment Failure Analysis↗