Search PubMed⌕ Search

PubMed · 15262643

Reducing the lateral force acting on the patella does not consistently decrease patellofemoral pressures.

Abstract

BACKGROUND: Extensor mechanism procedures that decrease the lateral component of the patellar tendon or quadriceps force acting on the patella do not consistently reduce pain. HYPOTHESIS: Patellofemoral treatments do not consistently decrease patellofemoral pressures because of variations in the moments acting on the patella. STUDY DESIGN: Computer simulation study. METHODS: Computational models of 4 knees were constructed to characterize the patellofemoral pressure distribution during simulated squatting from 40 degrees to 90 degrees. The knees were given an initial Q angle of 25 degrees. Patellofemoral treatments were simulated by increasing the percentage of the quadriceps force applied by the vastus medialis by 50% and by medializing the tibial tuberosity to decrease the Q angle to 15 degrees. RESULTS: Decreasing the Q angle caused a larger decrease in the lateral component of the force applied by the quadriceps and patellar tendon than did increasing the force applied by the vastus medialis and, therefore, was more effective at decreasing patellofemoral pressures and the force needed to resist lateral subluxation. Both treatments also decreased the moments acting to rotate the distal patella laterally and tilt the patella laterally during flexion. Variations in these moments increased patellofemoral pressures for some knees. CONCLUSIONS: Treatments that reduce patellofemoral subluxation can have an unexpected influence on patellofemoral pressures because of the moments acting on the patella. CLINICAL RELEVANCE: Extensor mechanism procedures that restore patellofemoral stability may not provide pain relief.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John J Elias, Jennifer A Cech, David M Weinstein, Andrew J Cosgrea. 2004-05-18. Reducing the lateral force acting on the patella does not consistently decrease patellofemoral pressures.. https://doi.org/10.1177/0363546503262167

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tomato (Lycopersicon esculentum Mill.) fruit growth and ripening as related to the biomechanical properties of fruit skin and isolated cuticle.

The control of growth rate and the mechanical integrity of the tomato (Lycopersicon esculentum Mill.) fruit has been attributed to the exocarp. This study focused on the biomechanics of the fruit skin (FS) comprising cuticle, epidermis and a few subdermal cell layers, and the enzymatically isolated cuticular membrane (CM) during fruit growth and ripening. Morphology and mechanical properties of the FS and the CM of three cultivars were analysed separately at three distinct ripening stages by scanning electron microscopy (SEM) and one-dimensional tension testing, respectively. Both were subject to significant cultivar-specific changes. Thickness of the CM increased during ripening from 7.8-8.6 to 9.9-15.7 microm and exceeded by far that of the epidermal cell wall. The mechanical properties, such as modulus of elasticity, strength, and failure strain, were highest in the FS for all cultivars at any stage, with only one exception; however, the cuticle largely mirrored these properties throughout fruit maturation. Stiffness of both isolated CM and FS increased from immature to fully ripe fruits for all cultivars, while failure stress and failure strain displayed a tendency to decrease for two of them. Stress-strain behaviour of the CM could be described as strain softening, mostly linear elastic throughout, and strain hardening, and was subject to growth-related changes. The FS displayed strain hardening throughout. The results indicate evidence for the cuticle to become increasingly important as a structural component for the integrity of the tomato fruit in addition to the epidermis. A supplementary putative model for tomato fruit growth is proposed.

Biomechanical Phenomena↗

Biomechanical in vitro comparison of different mono- and bisegmental anterior procedures with regard to the strategy for fracture stabilisation using minimally invasive techniques.

Endoscopic minimally invasive techniques have become an established method of fracture stabilisation in the spine. In view of this fact, anterior stabilisation strategies must be reconsidered, as monosegmental A 3.1 compression fractures are increasingly being stabilised endoscopically from the anterior aspect using minimally invasive techniques. This study investigated the biomechanical necessity of anterior two-point or four-point stabilisation in the instrumentation of mono- and bisegmental fractures. In three biomechanical in vitro studies, burst fracture stabilisation was simulated, and anterior short fixation devices were tested under load with pure moments up to 3.75 Nm to evaluate the biomechanical stabilising characteristics of different kinds of instrumentations in flexion/extension, lateral bending, and axial rotation. Only anterior four-point stabilisation resulted in sufficient primary stability both in mono- and bisegmental instrumentation and therefore represents the standard procedure in open as well as in minimally invasive spinal surgery.

Biomechanical Phenomena↗

Diffusivity of solutes measured in glass capillaries using Taylor's analysis of dispersion and a commercial CE instrument.

We present a strategy for the rapid, efficient, and accurate measurement of the coefficient of diffusion (D) of solutes using a commercial capillary electrophoresis (CE) instrument. This approach utilizes the classic analysis of Taylor of the dispersion of solutes pumped hydrostatically through glass capillaries. To obtain accurate values of D, we modified Taylor's analysis of dispersion to account for the finite time required to reach steady-state flow in the capillary when using a CE instrument. Neglecting this effect results in measured diffusivities of phenylalanine, a model solute, that are in error by as much as 60% when compared with published values. We provide an analysis of this effect and a simple strategy for avoiding these errors. Using this approach, we analyze profiles of concentration fronts and measured values of D for phenylalanine to within 5% of published values. We also analyze profiles of pulses of solute. To determine values of D accurately, measurements of dispersion first need to be made as a function of injection volume to correct for the finite width of the injection plug, before they are corrected for unsteady-state flow. This approach also yields values of D for phenylalanine to within 5% of published values. In contrast to other techniques used for the determination of D, this approach requires no fluorescent labeling and is applicable to solutes of any molecular weight.

Biomechanical Phenomena↗