Search PubMed⌕ Search

Biomedical subjects

John J Elias

Publications and source records attributed to John J Elias.

11 recordsLinked to original sources

Technical errors during medial patellofemoral ligament reconstruction could overload medial patellofemoral cartilage: a computational analysis.

BACKGROUND: The influence of reconstruction of the medial patellofemoral ligament on the patellofemoral force and pressure distributions has not yet been investigated. HYPOTHESIS: Technical errors can cause tension to develop within a reconstructed medial patellofemoral ligament, which will adversely alter the normal patellofemoral force distribution by increasing the load applied to the medial cartilage. STUDY DESIGN: Controlled laboratory study. METHODS: Four computational knee models were used to simulate knee function from 30 degrees to 90 degrees of flexion with (1) an intact medial patellofemoral ligament, (2) an anatomically correct reconstruction using a double hamstring tendon autograft, (3) a 5-mm proximally malpositioned femoral attachment site, (4) a graft that is 3 mm shorter than the intact medial patellofemoral ligament, and (5) combined proximal malpositioning and a short graft. RESULTS: The results were similar for the intact and anatomically reconstructed medial patellofemoral ligament. Proximal malpositioning of the femoral attachment and using a short graft increased the graft tension during flexion, which decreased the lateral force and the lateral tilt moment acting on the patella. When a short graft was combined with proximal malpositioning, the compressive force applied to the medial cartilage at least doubled at low flexion angles, which increased the peak medial pressure by more than 50% at low flexion angles. CONCLUSION: When the medial patellofemoral ligament is reconstructed, small errors in graft length and position can dramatically increase the force and pressure applied to medial patellofemoral cartilage. CLINICAL RELEVANCE: Overloading the medial cartilage after medial patellofemoral ligament reconstruction could lead to degradation, pain, and arthrosis.

Cartilage, Articular↗

Comparing two estimations of the quadriceps force distribution for use during patellofemoral simulation.

EMG analysis has indicated that the vastus lateralis and vastus medialis contribute less to the quadriceps moment during knee extension than the physiological cross-sectional areas (PCSA's) of the muscles indicate. Both PCSA- and EMG-based quadriceps force distributions were utilized while computationally simulating knee extension. For both distributions, a 10 degrees increase in the Q-angle and a 50% decrease in the force applied by the vastus medialis were simulated, and the influence of these changes on the resultant force and moment applied by the quadriceps muscles and the patella tendon was quantified. For both quadriceps force distributions, increasing the Q-angle increased the lateral force and the moment acting to rotate the distal patella laterally. Due to the relatively large forces initially attributed to the vastus medialis and vastus lateralis for the PCSA-based quadriceps force distribution, decreasing the vastus medialis force created a large force imbalance between these two muscles. For the PCSA-based quadriceps force distribution, decreasing the vastus medialis force increased the lateral rotation moment and the moment acting to tilt the patella laterally. For the EMG-based quadriceps force distribution, decreasing the vastus medialis force produced relatively little change in the tilt and rotation moments. For both quadriceps force distributions, increasing the Q-angle increased the maximum and mean cartilage pressure during flexion, but decreasing the vastus medialis force only increased the cartilage pressures for the PCSA-based quadriceps distribution. The choice of the initial quadriceps distribution can influence the outcome of patellofemoral simulation when manipulating quadriceps muscle forces.

Anatomy, Cross-Sectional↗

Viscoelasticity and temperature variations decrease tension and stiffness of hamstring tendon grafts following anterior cruciate ligament reconstruction.

BACKGROUND: Hamstring tendon grafts used for anterior cruciate ligament reconstruction are typically harvested early in the surgical procedure and are preconditioned prior to reimplantation. Postoperatively, the grafts undergo stress relaxation and warm from the temperature of the operating room to body temperature. The hypothesis of this study was that the tension within semitendinosus and gracilis tendon grafts and the stiffness of the grafts significantly decrease postoperatively because of both stress relaxation and an increase in temperature. METHODS: Double-strand grafts were created from six semitendinosus tendons and six gracilis tendons harvested from cadaver specimens. The grafts were loaded to 65 N while at operating-room temperature (20 degrees C). After fifteen minutes of stress relaxation, graft tension was measured and the grafts were stretched by 0.1 mm to determine stiffness. The tension and stiffness measurements represented graft properties immediately following reconstruction. Additional tension and stiffness measurements were made following three hours of stress relaxation and after increasing the temperature to the body temperature at the knee (34 degrees C). Both types of graft were examined for differences in stiffness and tension due to stress relaxation and the temperature increase. RESULTS: For both types of graft, the tension and stiffness decreased following stress relaxation to approximately 50% and 80%, respectively, of the value immediately after reconstruction. Increasing the temperature decreased the tension and stiffness further to approximately 40% and 70%, respectively, of the value after reconstruction for both types of graft. All changes in tension and stiffness were significant (p < 0.01). CONCLUSIONS: Graft tension and stiffness achieved immediately following reconstruction are not maintained postoperatively because of stress relaxation and a temperature increase. This could lead to increased knee laxity.

Aged↗

Structural properties of lateral collateral ligament reconstruction at the fibular head.

BACKGROUND: Anatomical reconstruction of a ruptured lateral collateral ligament using allograft tissue secured within the fibular head with an interference screw has been described. HYPOTHESIS: Interference fixation at the fibular head does not reproduce the strength of the intact ligament. STUDY DESIGN: Controlled laboratory study. METHODS: Ten intact lateral collateral ligaments were tested to failure. The distal fixation of 11 ligaments reconstructed with a graft including a bone plug and 11 ligaments reconstructed with a graft without a bone plug were also tested. RESULTS: The reconstructed ligaments consistently failed at the fibular head. The intact specimens predominately failed through ligament rupture. The mean strength and stiffness values were 460 +/- 163 N and 82 +/- 25 N/mm, respectively, for the intact ligaments, 113 +/- 40 N and 36 +/- 10 N/mm, respectively, for reconstruction with a bone plug, and 135 +/- 81 N and 34 +/- 14 N/mm, respectively, for reconstruction without a bone plug. The strength and stiffness were significantly (P < .05) greater for the intact ligaments than for either reconstruction group. The variation in strength was significantly larger for reconstruction without a bone plug than for reconstruction with a bone plug. CONCLUSION: Tension applied to lateral collateral ligaments reconstructed using fibular interference fixation should be limited immediately after surgery. Soft tissue fixation should be employed with care because of the inconsistency in the failure strength. CLINICAL RELEVANCE: Although fibular interference fixation is increasingly being described in the literature, the properties of reconstructed lateral collateral ligaments have not previously been quantified.

Bone Screws↗

Reducing the lateral force acting on the patella does not consistently decrease patellofemoral pressures.

BACKGROUND: Extensor mechanism procedures that decrease the lateral component of the patellar tendon or quadriceps force acting on the patella do not consistently reduce pain. HYPOTHESIS: Patellofemoral treatments do not consistently decrease patellofemoral pressures because of variations in the moments acting on the patella. STUDY DESIGN: Computer simulation study. METHODS: Computational models of 4 knees were constructed to characterize the patellofemoral pressure distribution during simulated squatting from 40 degrees to 90 degrees. The knees were given an initial Q angle of 25 degrees. Patellofemoral treatments were simulated by increasing the percentage of the quadriceps force applied by the vastus medialis by 50% and by medializing the tibial tuberosity to decrease the Q angle to 15 degrees. RESULTS: Decreasing the Q angle caused a larger decrease in the lateral component of the force applied by the quadriceps and patellar tendon than did increasing the force applied by the vastus medialis and, therefore, was more effective at decreasing patellofemoral pressures and the force needed to resist lateral subluxation. Both treatments also decreased the moments acting to rotate the distal patella laterally and tilt the patella laterally during flexion. Variations in these moments increased patellofemoral pressures for some knees. CONCLUSIONS: Treatments that reduce patellofemoral subluxation can have an unexpected influence on patellofemoral pressures because of the moments acting on the patella. CLINICAL RELEVANCE: Extensor mechanism procedures that restore patellofemoral stability may not provide pain relief.

Biomechanical Phenomena↗

Evaluation of a computational model used to predict the patellofemoral contact pressure distribution.

One possible cause of patellofemoral pain syndrome is excessive lateral force acting on the patella. Although several treatment methods focus on decreasing the lateral force acting on the patella, the relationship between the lateral force and the patellofemoral contact pressure distribution is unclear. A computational model has been developed to determine how loading variations alter the patellofemoral force and pressure distributions for individual knees. The model allows variation in the quadriceps and patella tendon forces, and calculates the predicted contact pressure distribution using the discrete element analysis technique. To characterize the accuracy of the model, four cadaver knees were flexed on a knee simulator with three initial Q-angles, while recording the force and pressure distributions with a pressure sensor. A model of each knee was created from CT data. Using the external force applied to the knee, the geometry of the knee, and the quadriceps origin as input, the pressure distribution was calculated during flexion. Similar trends were noted for the computational and experimental results. The percentage of the total force applied to the lateral cartilage increased with the Q-angle. The maximum contact pressure increased during flexion. The maximum lateral contact pressure increased with the Q-angle for three knees. For the other knee, increasing the Q-angle decreased the maximum lateral pressure. The maximum medial contact pressure decreased as the Q-angle increased. By characterizing the influence of patellofemoral loading on the force and pressure distributions, the computational model could be used to evaluate treatment methods prescribed for patellofemoral pain.

Cadaver↗

In vitro kinematic patterns are similar for a fixed platform and a mobile bearing prosthesis.

In vitro dynamic simulation of knee flexion was performed to quantify knee kinematics for a mobile bearing prosthesis that allows the tibial insert to translate and rotate with respect to the baseplate. Six cadaver knees were tested in the intact state, after implanting a fixed platform prosthesis, and after implanting a mobile bearing prosthesis. The mobile bearing prosthesis significantly increased the tibial internal rotation and medial shift compared with the intact knee, near 90 degrees of flexion. Both prostheses increased the patellar medial shift near 90 degrees of flexion. The patellar flexion was significantly larger for the mobile bearing prosthesis than for the fixed platform prosthesis for most of flexion. Motion of the insert with respect to the baseplate may have contributed to the variations in tibiofemoral kinematics, whereas tibiofemoral kinematic changes influenced the patellofemoral kinematics. Although the kinematics were similar for the 2 types of prosthesis, the possibility of complications related to increased patellar flexion and backside wear of the tibial insert should be considered.

Aged↗

Posterior cruciate ligament rupture alters in vitro knee kinematics.

Isolated posterior cruciate ligament injuries usually are treated nonoperatively, although some patients remain symptomatic, and degenerative changes within the patellofemoral joint and the medial compartment of the tibiofemoral joint have been seen in followup studies. In vitro simulation of knee squatting was done to quantify the influence of the posterior cruciate ligament on tibiofemoral and patellofemoral kinematics. For five knee specimens, knee kinematics were measured before and after sectioning the posterior cruciate ligament, and compared using a Wilcoxon signed rank test. The only kinematic parameters that changed significantly after sectioning the posterior cruciate ligament were the tibial posterior translation and patellar flexion. The posterior translation of the tibia increased significantly between 25 degrees and 90 degrees flexion. The average increase in the posterior translation exceeded 10 mm at 90 degrees flexion. The patellar flexion increased significantly from 30 degrees to 90 degrees flexion. The average patellar flexion increase peaked at 4.4 degrees at 45 degrees flexion. Increased tibial translation could adversely influence joint stability. Increased patellar flexion could increase the patellofemoral joint pressure, especially at the inferior pole, leading to degenerative changes within the patellofemoral joint.

Aged↗

Quantitation of breast sensibility following reduction mammaplasty: a comparison of inferior and medial pedicle techniques.

The preservation of sensitivity within the nipple-areola complex is of paramount importance to patients presenting for reconstructive and aesthetic breast procedures. Previous attempts to measure sensation in the breast before and after surgery have relied primarily on the Semmes-Weinstein monofilament test, which is an imprecise study that measures the logarithm of force necessary to bend a series of six to 20 filaments. Within the last 10 years, various authors have published normative pressure threshold data for the breast that have varied by a magnitude of greater than 10-fold. Recently, precise anatomic studies have been performed that have elucidated the innervation of the nipple-areola complex medially and laterally from cutaneous branches of the intercostal nerves. Despite this knowledge, no quantitative sensibility studies have yet been performed that compare postoperative sensation when medially versus laterally innervated pedicles have been used in reduction mammaplasty. The present study is the first to use computer-assisted neurosensory testing to generate normal breast sensation data and to compare sensory outcomes between the inferior and the medial pedicle techniques of reduction mammaplasty.A total of 34 patients were divided into four groups and underwent breast sensory testing (67 breasts total) using the Pressure-Specified Sensory Device, a computer-assisted force transducer that measures static and moving one and two-point discrimination. Sensation in the nipple and in the four quadrants of the areola was measured. Groups I and II were composed of 17 unoperated controls with breast sizes ranging from 34A to 36C (group I; 18 breasts) and 36DD to 46EE (group II; 16 breasts) who presented to a general plastic surgery clinic. Groups III and IV were composed of 17 patients who underwent either medial or inferior pedicle reduction mammaplasty between July of 1997 and March of 1999. Pressure thresholds in the most sensitive breasts were as low as 0.3 g/mm2, a marked contrast to data from previous studies using Semmes-Weinstein monofilaments documenting the lowest recordable pressure threshold as greater than 2 g/mm2. Several findings from previous studies using Semmes-Weinstein monofilament testing were confirmed in unoperated controls, including an inverse relationship between sensitivity and breast size, superior nipple sensitivity when compared with the areola, and significant interpatient variability with respect to static and moving two-point discrimination among women matched according to age and breast size. When comparing medial with inferior pedicle reduction mammaplasty patients, it was found that despite significantly greater reductions using the medial pedicle technique (mean of 1.7 kg versus 1.1 kg of breast tissue removed), there were no significant differences in postoperative sensory outcomes in the sample size of 17 patients. Furthermore, within each group of patients undergoing either the medial or inferior pedicle technique, the amount of breast tissue removed did not correlate with postoperative sensory outcomes.Computer-assisted quantitative neurosensory testing is a highly accurate technique for measuring sensibility. The use of this technology demonstrates a 10-fold difference in measurable sensory thresholds in normal patients from preexisting data using Semmes-Weinstein monofilaments. Advances in measurement methods have allowed the authors to compare postoperative sensory outcomes reliably using two popular techniques of reduction mammaplasty.

Adolescent↗

Locking plates improve torsional resistance in the stabilization of three-part proximal humeral fractures.

This study quantified the torsional resistance provided by locking plates and angled blade plates used to stabilize proximal humeral fractures. Three-part proximal humeral fractures were created in 6 pairs of cadaveric humeri. One specimen of each pair was reconstructed with a proximal humeral locking plate, whereas the other specimen was reconstructed with an angled blade plate. An external rotation torque, varying from 0 to 5 N-m, was applied to the humeral head until the head rotated 30 degrees or 10,000 loading cycles were applied. The mean initial torsional stiffness was significantly larger for the locking plates (0.99 N-m/degree) than for the blade plates (0.59 N-m/degree). For each pair, the maximum rotation was larger for the blade plate than for the locking plate. For this in vitro model of a reconstructed 3-part proximal humeral fracture, the locking plate provided better torsional fatigue resistance and stiffness than the blade plate.

Aged↗

The soleus muscle acts as an agonist for the anterior cruciate ligament. An in vitro experimental study.

BACKGROUND: Although the quadriceps muscles are known antagonists for the anterior cruciate ligament and the hamstring muscles are known agonists, the influence of the calf muscles on knee stability is not well understood. HYPOTHESIS: The soleus muscle acts as an anterior cruciate ligament agonist and the gastrocnemius muscle acts as an anterior cruciate ligament antagonist. STUDY DESIGN: Controlled laboratory study. METHODS: Six cadaveric knees were tested with individual and combined activation of the gastrocnemius and soleus muscles to determine the influence of simulated muscle contraction on tibiofemoral motion. RESULTS: At all flexion angles, applying the soleus muscle force tended to translate the tibia posteriorly, whereas applying the gastrocnemius muscle force tended to translate the tibia anteriorly. Applying the soleus and gastrocnemius muscle forces together also tended to translate the tibia anteriorly. The average anterior and posterior tibial translations were greatest at 50 degrees of flexion. CONCLUSIONS: The soleus muscle is capable of acting as an agonist for the anterior cruciate ligament and the gastrocnemius muscle can act as an antagonist. CLINICAL RELEVANCE: A better understanding of the agonistic behavior of the soleus muscle on the anterior cruciate ligament may lead to the development of training and rehabilitation strategies that could reduce the incidence of injury and improve function in both patients with anterior cruciate ligament deficiency and patients who have undergone anterior cruciate ligament reconstruction.

Aged↗