Search PubMed⌕ Search

PubMed · 15152682

Developing a quality control protocol for diffusion imaging on a clinical MRI system.

Abstract

This work describes the development of a quality control protocol, which can be implemented to assess the accuracy, precision and reproducibility of the apparent diffusion coefficient (ADC) measurement on a clinical magnetic resonance imaging (MRI) system. The precision and accuracy of the ADC measurement are analysed with regard to MRI system noise, signal reproducibility and differences between nominal and effective b values. Two aqueous test-solutions of CuSO4 and sucrose are prepared for the quality control protocol. ADC measurement with the CuSO4 solution is more sensitive to differences between nominal and effective b values, on account of the solution's high ADC. ADC measurement with the sucrose solution is more sensitive to signal reproducibility due to the solution's low baseline signal intensity. The ADC of the test-solutions is measured on an MRI system at our centre with a sequence used for clinical studies using diffusion imaging. Two parameters, Q and R, are defined for the analysis of the quality control ADC values. The Q parameter is the ratio of the standard deviation of the quality control mean ADC values over time to the optimal standard deviation, as derived from the effect of thermal noise on the ADC measurement uncertainty. Analysis with the Q parameter indicates that signal reproducibility errors contribute to ADC variations on our MRI system when imaging with high b values (b > 500 mm s(-2)), whereas differences between nominal and effective b values have a greater impact on the ADC measurement when imaging with low b values (b < 500 mm s(-2)). The R parameter is defined as the ratio of the directional variation of the ADC quality control values to the uncertainty of the ADC measurement. Analysis with the R parameter shows that the effect of directional variation of the ADC measurement on our MRI system is more pronounced when imaging with low b values. The quality control protocol identified a systematic error, which introduced a small system-induced anisotropy in the ADC measurement. This error is currently taken into account in the analysis of clinical studies employing the diffusion imaging sequence used in this quality control protocol.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ioannis Delakis, Elizabeth M Moore, Martin O Leach, Janet P De Wilde. 2004-04-21. Developing a quality control protocol for diffusion imaging on a clinical MRI system.. https://doi.org/10.1088/0031-9155%2F49%2F8%2F003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Protein dynamics from X-ray crystallography: anisotropic, global motion in diffuse scattering patterns.

Understanding X-ray crystallographic diffuse scattering is likely to improve our comprehension of equilibrium collective protein dynamics. Here, using molecular dynamics (MD) simulation, a detailed analysis is performed of the origins of diffuse scattering in crystalline Staphylococcal nuclease, for which the complete diffuse scattering pattern has been determined experimentally. The hydrogen-atom contribution and the scattering range over which the scattering can be considered to be a sum of solvent and protein scattering are determined. Two models of correlated protein motion are investigated by calculating the model-derived diffuse scattering and comparing with the scattering calculated directly from MD trajectories. In one model, previously used in diffuse scattering interpretation, the atomic displacement correlations decay isotropically with increasing separation. Model correlation lengths are obtained by refining the model scattering against the simulation-derived scattering pattern, and are found to be significantly different from those correlation lengths derived directly from the MD trajectories. Furthermore, the convergence between the model-derived and MD-derived scattering is poor. The second model, in which the displacement correlations are calculated from the principal components of the MD trajectories, is capable of fully reproducing the MD-derived diffuse scattering if the approximately 50% lowest-frequency modes are included. However, a small number ( approximately 10) of lowest-frequency and largest-amplitude modes dominates the diffuse scattering and thus the correlated protein motions. A detailed analysis of the principal components is performed. In particular, the effective free energy profile associated with each principle mode is analyzed and the eigenfrequency and damping coefficient computed using a model of Brownian dynamics. Those collective modes with effective frequencies below approximately 0.5 THz, including those that determine the diffuse scattering, are overdamped.

Anisotropy↗

(39)K NMR of solid potassium salts at 21 T: effect of quadrupolar and chemical shift tensors.

39K Solid State NMR spectra (static and magic angle spinning (MAS)) on a set of potassium salts measured at 21.14 T show that the chemical shift range for K(+) ions in diamagnetic salts is well in excess of 100 ppm contrary to previous assumptions that it was quite small. Inequivalent potassium sites in crystals can be resolved through differences in chemical shifts, with chemically similar sites showing differences of over 10 ppm. The quadrupolar coupling constants obtained from MAS and solid echo experiments on powders cover the range from zero for potassium in cubic environments in halides to over 3 MHz for the highly asymmetric sites in K2CO3. Although the quadrupolar effects generally dominate the 39K spectra, in several instances, we have observed subtle but significant contributions of chemical shift anisotropy with values up to 45 ppm, a first such observation. Careful analysis of static and MAS spectra allows the observation of the various chemical shift and quadrupole coupling tensor components as well as their relative orientations, thereby demonstrating that high-field 39K NMR spectroscopy in the solid state has a substantial sensitivity to the local environment with parameters that will be of considerable value in materials characterization and electronic structure studies.

Anisotropy↗