Search PubMed⌕ Search

PubMed · 14872212

Chulay commentary.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Marianne Chulay. 2004. Chulay commentary.. https://doi.org/10.1038/sj.jp.7211039

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fatigue sensitivity of Y-TZP to microscale sharp-contact flaws.

The strength degrading effects of sharp-contact damage are examined for Y-TZP ceramic plates bonded to a plastic substrate. Contacts are made with Vickers and Berkovich diamond indenters at low loads (0.1 N to 100 N) in the ceramic lower surfaces prior to bonding to the substrates. The indentations remain in the subthreshold region, that is, without visible corner radial cracks, over the lower region (< 10 N) of the load range. A concentrated load is then applied sinusoidally to the ceramic upper surface, with the loading axis centered on the subsurface indentation flaw, thereby subjecting the flaw to cyclic tension. Relative to polished surfaces, the indentations diminish the single-cycle strength by an amount that increases with increasing indentation load. The critical number of cycles required to cause failure from the indentation flaws is then measured at specified maximum lower surface tensile stresses. At each indentation load, the strength of the ceramic plates diminishes with increased cycling. The scale of degradation is compared with that from previous studies on Y-TZP surfaces containing larger-scale surface damage: sandblast damage, as used in dental crown preparation; and blunt-contact trauma from a spherical indenter at 3000 N. These other damage modes are shown to be equivalent in their strength-degrading capacity to diamond pyramid indentations in the microscale load range 0.1 N to 1 N, attesting to the highly deleterious nature of sharp particulate contacts. The mechanism of fatigue is considered in terms of microcrack evolution within the indentation damage zone.

Equipment Failure Analysis↗

[Factors influencing rehabilitation of sensorineural hearing loss with hearing aids].

BACKGROUND: A large proportion of older as well as younger patients do not use their hearing aids. Of the younger hearing impaired population, this occurs in the majority of those who do not benefit sufficiently from their hearing aids and, consequently, they face difficulties in their working and social life. SCIENTIFIC QUESTION: Our aim was to evaluate whether a classical hearing aid adjustment is of sufficient predictive value to determine whether adequate rehabilitation in everyday and professional life will occur. METHODS AND RESULTS: A questionnaire was returned by 197 adult hearing impaired patients. Only 108 were using their hearing aids all the time; 57 rarely and 32 never. The main reason for this low rehabilitation rate proved to be inadequate amplification. At the workplace, insufficient speech discrimination came into play. Another important factor was dysacusis induced by specific noise signals. There was an intolerable acoustic feedback in 40% which could not be sufficiently alleviated. Taking these results into account, only about a third of patients were sufficiently rehabilitated. CONCLUSIONS: Proof of effectiveness in a typical audiological testing situation is an important but not a fully reliable predictor for effectiveness in everyday life. Even when hearing aids are shown to be effective with such testing, their application in particular everyday or work situations may be insufficient of even impossible.

Equipment Failure Analysis↗

Mechanical evaluation of a respiratory device.

This article aims to characterize the mechanical behaviour of the Flutter VRP1, a respiratory physiotherapy device designed to aid sputum clearance of the airways of patients. The device resembles a smoking pipe with a conical cavity containing a stainless steel sphere which floats up and down while the patient comes with a forced expiration through it. The sphere's oscillatory movement is function of the air flow rate and angular orientation of the device. When the sphere's oscillatory frequency matches the natural frequency of the patient's chestwall+abdomen system, it will produce resonance which, in turn, will enhance sputum clearance. A dynamical model of the Flutter was formulated and an experimental setup was assembled in order to study the oscillatory frequency of the sphere under different conditions of air flow rate, fluid pressure, angular orientation and sphere's material and weight. Interesting results presented by this article point to eventual mechanical optimization of the device and show information that could be beneficial to the professional of the respiratory physiotherapy.

Equipment Failure Analysis↗